Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 3 min ago
Peer-reviewedCC BY-NC-SASaudi journal of anaesthesia

Target-level epidural catheter placement in lower thoracic spine using preprocedural ultrasound marking: A prospective observational study.

  1. 1Department of Anesthesiology, University of Tsukuba Hospital, Ibaraki, Japan.
  2. 2Department of Biostatistics, Institute of Medicine, University of Tsukuba, Ibaraki, Japan.
  3. 3Department of Anesthesiology, Institute of Medicine, University of Tsukuba, Ibaraki, Japan.

Abstract

Background

Accurate insertion of catheters into the target intervertebral level is essential for effective epidural anesthesia. However, conventional palpation-based methods are often unreliable, resulting in unintended motor weakness of the lower limbs when insertion is performed at the lower thoracic level. In this study, we evaluated the accuracy of placing an epidural catheter at the target intervertebral level in the lower thoracic spine using preprocedural ultrasound marking.Methods

In this prospective observational study, we enrolled 40 adults undergoing elective surgery with planned lower thoracic epidural anesthesia. After identifying the spinal level using ultrasound and marking the spinous and transverse processes as landmarks, the epidural catheter was placed at the target level. Postoperative radiographs were used to confirm the actual placement level. Accuracy was assessed based on whether the level at which the epidural catheter was actually placed matched the target intervertebral level.Results

Of the 40 patients, data of 37 were included in the final analysis. The accuracy rate relative to the target intervertebral level was 89.2% (33/37; 95% confidence interval: 74.6-97.0%). No major misplacements (≧2 interspaces) were observed.Conclusion

In the lower thoracic spine, the use of preprocedural ultrasound marking enabled highly accurate placement of epidural catheters at the target intervertebral level.

Related

  1. Microfocused ultrasound for facial and neck rejuvenation : A pilot prospective observational study on efficacy and safety in patients with skin laxity
    Zhonglan Pan, Yanqiu Tang, Sihui Wang +2
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  2. Ultrasound-guided peripheral regional anesthesia vs local infiltration anesthesia for cardiac device implantation: A propensity score–matched prospective observational cohort study
    Riyong Zhou, Ziyi Ni, Yaoxue Zang +8
    Heart rhythm O2Peer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Two-stage breast reconstruction comparison between prepectoral tissue expander wrapped within acellular dermal matrix versus subpectoral placement: the prospective observational EX-BRAX study.
    Marco Bernini, Alessandro Ammar, Matteo Enrico Sobrero +12
    Gland surgeryPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Early recognition and safe management of unintentional intrathecal placement of an epidural catheter during combined spinal-epidural labor analgesia: a case report in the context of the 2024 OAA guidelines.
    Hidenobu Watanabe, Choko Kume, Arisa Ijuin +3
    JA clinical reportsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCDOAJ
  5. Ultrasound-guided haemodynamic profiling in haemodialysis patients: a single-centre prospective observational study protocol
    Samuel Larsen, Fabio Silvio Taccone, Alain Le Moine +2
    Frontiers in nephrologyPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{sasaki2026targetlevel,
  title = {{Target-level epidural catheter placement in lower thoracic spine using preprocedural ultrasound marking: A prospective observational study.}},
  author = {Momoko Sasaki and Yuya Murata and Tetsuya Kodaira and Mayuko Nonaka and Kazushi Maruo and Jungo Kato},
  journal = {Saudi journal of anaesthesia},
  year = {2026},
  month = oct,
  doi = {10.4103/sja.sja_422_26},
  url = {https://europepmc.org/article/MED/42960042},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Target-level epidural catheter placement in lower thoracic spine using preprocedural ultrasound marking: A prospective observational study.
AU  - Momoko Sasaki
AU  - Yuya Murata
AU  - Tetsuya Kodaira
AU  - Mayuko Nonaka
AU  - Kazushi Maruo
AU  - Jungo Kato
PY  - 2026
DA  - 2026/10/01
JO  - Saudi journal of anaesthesia
DO  - 10.4103/sja.sja_422_26
UR  - https://europepmc.org/article/MED/42960042
AB  - Background  Accurate insertion of catheters into the target intervertebral level is essential for effective epidural anesthesia. However, conventional palpation-based methods are often unreliable, resulting in unintended motor weakness of the lower limbs when insertion is performed at the lower thoracic level. In this study, we evaluated the accuracy of placing an epidural catheter at the target intervertebral level in the lower thoracic spine using preprocedural ultrasound marking.Methods  In this prospective observational study, we enrolled 40 adults undergoing elective surgery with planned lower thoracic epidural anesthesia. After identifying the spinal level using ultrasound and marking the spinous and transverse processes as landmarks, the epidural catheter was placed at the target level. Postoperative radiographs were used to confirm the actual placement level. Accuracy was assessed based on whether the level at which the epidural catheter was actually placed matched the target intervertebral level.Results  Of the 40 patients, data of 37 were included in the final analysis. The accuracy rate relative to the target intervertebral level was 89.2% (33/37; 95% confidence interval: 74.6-97.0%). No major misplacements (≧2 interspaces) were observed.Conclusion  In the lower thoracic spine, the use of preprocedural ultrasound marking enabled highly accurate placement of epidural catheters at the target intervertebral level.
SN  - 1658-354X
SN  - 0975-3125
ER  -