Peer-reviewedCC BY 4.0Diagnostics

Performance Evaluation of Deep Learning Applications in Calcaneal Fracture Diagnosis Using Separate Radiographic Views: A Comparison of CNN and Vision Transformer Architectures

5 affiliations
  1. 1Department of Orthopaedics, Taichung Veterans General Hospital, Taichung 407219, Taiwan
  2. 2Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung 40227, Taiwan
  3. 3Bachelor Degree Program of Artificial Intelligence, National Taichung University of Science and Technology, Taichung 404336, Taiwan
  4. 4Department of Electrical Engineering, National Chung Hsing University, Taichung 40227, Taiwan
  5. 5Department of Materials Science and Engineering, Feng Chia University, Taichung 407102, Taiwan

Abstract

Background: Calcaneal fractures are challenging to diagnose on routine radiographs and may result in missed diagnoses. Objective: This study compares Convolutional Neural Networks (CNNs) and Vision Transformer (ViT) architectures for detecting calcaneal fractures separately in three standard radiographic views: Anteroposterior (AP), Harris (axial), and Lateral. Methods: A balanced retrospective dataset of 178 patients with complete three-view examinations (89 with displaced calcaneal fractures and 89 controls) was used to evaluate five deep learning models: ResNet50, InceptionV3, InceptionResNetV2, XCiT, and PiT. After image-quality screening, each view underwent an approximately 8:2 image-level training–validation split; no independent test set was used. Images were preprocessed using data augmentation and Contrast Limited Adaptive Histogram Equalization (CLAHE), while Gradient-weighted Class Activation Mapping (Grad-CAM) was employed to visualize model activation. Results: InceptionV3 achieved 100% sensitivity in the AP view, while ResNet50 achieved 100% specificity in both AP and Lateral views. XCiT matched ResNet50 across all five classification metrics in the AP view and matched ResNet50 and InceptionV3 in the Lateral view. PiT achieved 100% accuracy in the Harris validation set (95% CI, 89.0–100.0%). Grad-CAM visualizations showed activation over the calcaneal region in representative fracture images. Conclusions: This study demonstrates the feasibility of deep learning for identifying displaced calcaneal fractures through separate evaluations of AP, Harris, and Lateral radiographs. The model-specific performance patterns provide a foundation for further development of AI-assisted calcaneal fracture detection and future investigation of multi-view integration.

Related

  1. A Novel MR Elastography Device for Preclinical Applications From Spheroids to Rodents: Design, Validation, and Performance Evaluation
    Gabrielle Mangin, Hannah Fels‐palesandro, Valéria Bisio +12
    NMR in BiomedicinePeer-reviewedCC BY 4.0Full textMedical imaging & radiologyHAL
  2. Radiographic Evaluation of Scoliosis in Pediatric, Adolescent, and Young Adult Patients: Associations Between Curve Severity, Localization, and Skeletal Maturity
    Alpár Pászka, Zsuzsánna Pap
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Radiographic Evaluation of a Threshold-Based Latent Medial Laxity Adjustment for Coronal Alignment After Medial Open-Wedge High Tibial Osteotomy
    Samuel Jaeyoon Won, Yoon Sang Jeon, Jin Seong Park +4
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Diagnostic Performance of a Vision Transformer Model in Differentiating Cicatricial from Non-Cicatricial Alopecia in Trichoscopic Images
    Ahmet Sait Şahin, Abdurrahim Yılmaz, Buğra Burç Dağtaş +2
    Dermatology practical & conceptualPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMCPMC
  5. Transformer models in cardiovascular medicine: current applications, translational challenges, and future directions.
    Yang Yan, Gaoxiang Li, Taiwei Chen +5
    Frontiers in artificial intelligencePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
BibTeX
@article{wang2026performance,
  title = {{Performance Evaluation of Deep Learning Applications in Calcaneal Fracture Diagnosis Using Separate Radiographic Views: A Comparison of CNN and Vision Transformer Architectures}},
  author = {Shun-Ping Wang and Yu-Wei Chan and Yi-Cyuan Tseng and Wei-En Hsu},
  journal = {Diagnostics},
  year = {2026},
  month = nov,
  doi = {10.3390/diagnostics16213682},
  url = {https://doi.org/10.3390/diagnostics16213682},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Performance Evaluation of Deep Learning Applications in Calcaneal Fracture Diagnosis Using Separate Radiographic Views: A Comparison of CNN and Vision Transformer Architectures
AU  - Shun-Ping Wang
AU  - Yu-Wei Chan
AU  - Yi-Cyuan Tseng
AU  - Wei-En Hsu
PY  - 2026
DA  - 2026/11/07
JO  - Diagnostics
DO  - 10.3390/diagnostics16213682
UR  - https://doi.org/10.3390/diagnostics16213682
AB  - Background: Calcaneal fractures are challenging to diagnose on routine radiographs and may result in missed diagnoses. Objective: This study compares Convolutional Neural Networks (CNNs) and Vision Transformer (ViT) architectures for detecting calcaneal fractures separately in three standard radiographic views: Anteroposterior (AP), Harris (axial), and Lateral. Methods: A balanced retrospective dataset of 178 patients with complete three-view examinations (89 with displaced calcaneal fractures and 89 controls) was used to evaluate five deep learning models: ResNet50, InceptionV3, InceptionResNetV2, XCiT, and PiT. After image-quality screening, each view underwent an approximately 8:2 image-level training–validation split; no independent test set was used. Images were preprocessed using data augmentation and Contrast Limited Adaptive Histogram Equalization (CLAHE), while Gradient-weighted Class Activation Mapping (Grad-CAM) was employed to visualize model activation. Results: InceptionV3 achieved 100% sensitivity in the AP view, while ResNet50 achieved 100% specificity in both AP and Lateral views. XCiT matched ResNet50 across all five classification metrics in the AP view and matched ResNet50 and InceptionV3 in the Lateral view. PiT achieved 100% accuracy in the Harris validation set (95% CI, 89.0–100.0%). Grad-CAM visualizations showed activation over the calcaneal region in representative fracture images. Conclusions: This study demonstrates the feasibility of deep learning for identifying displaced calcaneal fractures through separate evaluations of AP, Harris, and Lateral radiographs. The model-specific performance patterns provide a foundation for further development of AI-assisted calcaneal fracture detection and future investigation of multi-view integration.
SN  - 2075-4418
ER  -