A Tutorial on Measurement of Electrochemical Water-Splitting Performance Parameters: Methods and Best Practices.
- 1Advanced Materials and Device (A-MAD) Laboratory, Department of Physics, Indian Institute of Technology Jodhpur, Jodhpur, Rajasthan-342030, India.
- 2Department of Physics, Indian Institute of Technology Ropar, Rupnagar, Punjab-140001, India.
- 3Rishabh Centre for Research and Innovation in Clean Energy, Indian Institute of Technology Jodhpur, Jodhpur, Rajasthan-342030, India.
Abstract
Electrochemical water splitting has emerged as a promising route to sustainable, green hydrogen production, playing a key role in advancing clean energy systems. The continued advancement of water electrolysis relies heavily on the rational design and evaluation of efficient, durable, and cost-effective electrocatalysts. However, a meaningful and fair comparison of electrocatalyst performance depends on accurate and standardized measurement protocols. This tutorial provides an in-depth overview of the best measurement practices for assessing performance parameters, including overpotential, Tafel slope, charge transfer, electrolyte resistance, electrochemical surface area, turnover frequency, stability, and Faradaic efficiency of electrocatalysts for water splitting. More emphasis is given on highlighting the strengths and limitations of various electrochemical methods, such as linear sweep voltammetry (LSV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and chronopotentiometry (CP). Further, special attention is given to proper iR compensation, selection of appropriate scan rates, and identification of the non-Faradaic region for accurate determination of electrochemical surface area (ECSA). The role of redox peak integration in estimating active site densities, particularly for transition-metal-based electrocatalysts, is also a focus. The transition from standard three-electrode testing to a full-cell alkaline water electrolyzer is also discussed in detail, highlighting standard protocols to minimize the gap between lab-scale testing and commercial-scale electrolyzers. Thus, overall, this tutorial can be considered a practical guide for academicians and researchers, especially beginners in the field, aiming to enhance the reliability of electrochemical measurements and further catalyze the innovation and development of high-performance, energy-efficient water-splitting electrocatalysts for green hydrogen production.
Related
- Superhydrophobic Porous Coordination Polymer-Confined Co3O4 Nanoparticles: A Sustainable Strategy for Electrochemical Water Splitting
- Different percentages of metal doping in lithium titanate for the enhancement of electrochemical water splitting
- Cobalt induced electronic and defect structure modulation in nickel iron layered double hydroxides for electrochemical, photo-electrochemical and photocatalytic water splitting.
- Electrochemical functionalization of graphene rationalized by Hammett and Swain-Lupton parameters
- Performance and Design Limits of Membraneless Flow Electrochemical Cells: A Combined Secondary Current and Multiphase Flow Analysis
BibTeX
@article{sharma2026tutorial,
title = {{A Tutorial on Measurement of Electrochemical Water-Splitting Performance Parameters: Methods and Best Practices.}},
author = {Minakshi Sharma and Chandra Prakash and Vijay K Singh and Ambesh Dixit},
journal = {ACS measurement science au},
year = {2026},
month = aug,
doi = {10.1021/acsmeasuresciau.6c00147},
url = {https://europepmc.org/article/MED/42921415},
note = {CC BY},
}
RIS
TY - JOUR
TI - A Tutorial on Measurement of Electrochemical Water-Splitting Performance Parameters: Methods and Best Practices.
AU - Minakshi Sharma
AU - Chandra Prakash
AU - Vijay K Singh
AU - Ambesh Dixit
PY - 2026
DA - 2026/08/21
JO - ACS measurement science au
DO - 10.1021/acsmeasuresciau.6c00147
UR - https://europepmc.org/article/MED/42921415
AB - Electrochemical water splitting has emerged as a promising route to sustainable, green hydrogen production, playing a key role in advancing clean energy systems. The continued advancement of water electrolysis relies heavily on the rational design and evaluation of efficient, durable, and cost-effective electrocatalysts. However, a meaningful and fair comparison of electrocatalyst performance depends on accurate and standardized measurement protocols. This tutorial provides an in-depth overview of the best measurement practices for assessing performance parameters, including overpotential, Tafel slope, charge transfer, electrolyte resistance, electrochemical surface area, turnover frequency, stability, and Faradaic efficiency of electrocatalysts for water splitting. More emphasis is given on highlighting the strengths and limitations of various electrochemical methods, such as linear sweep voltammetry (LSV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and chronopotentiometry (CP). Further, special attention is given to proper iR compensation, selection of appropriate scan rates, and identification of the non-Faradaic region for accurate determination of electrochemical surface area (ECSA). The role of redox peak integration in estimating active site densities, particularly for transition-metal-based electrocatalysts, is also a focus. The transition from standard three-electrode testing to a full-cell alkaline water electrolyzer is also discussed in detail, highlighting standard protocols to minimize the gap between lab-scale testing and commercial-scale electrolyzers. Thus, overall, this tutorial can be considered a practical guide for academicians and researchers, especially beginners in the field, aiming to enhance the reliability of electrochemical measurements and further catalyze the innovation and development of high-performance, energy-efficient water-splitting electrocatalysts for green hydrogen production.
SN - 2694-250X
ER -