Biomimetic hydrophobic gating in MXene polypyrrole–based artificial Ion channels for efficient perchlorate sensing
Abstract
Ion selective electrodes represent a promising approach for ion detection based on potentiometric sensing principle. However, their practical application is often hampered by insufficient selectivity, primarily caused by interference from structurally similar ions. Herein, inspired by biological potassium ion channels, we demonstrate an efficient perchlorate ion selective electrode via the self–assembly of pyrrole–functionalized MXene nanosheets and methylated quaternary ammonium compounds. The resulting composite sensor significantly outperforms commercial ion selective electrodes with a > 10 ⁴ –fold lower detection limit (10 –9.7 M), 18–fold higher selectivity ( K ij of 130.4), and a maximum sensitivity up to 59.6 mV/dec for perchlorate. Synchrotron X–ray scattering and mechanistic studies attribute this superior performance to a hydrophobic gating mechanism arising from dehydration effects and transport resistance within confined channels, which effectively lowers the energy barrier for perchlorate transport by 12.13 kcal/mol compared to that of sulfate. Furthermore, the sensor was optimized via substituent engineering for broad-spectrum anion detection and integrated into a portable platform for continuous on–site monitoring, achieving accuracy comparable to ion chromatography in real–world scenarios.
Related
- Multi-site Cleavage of Amyloid-β by a Minimal 5-mer Catalytic Peptide: Mimicking Serine Protease Activity via Hydrophobic Anchoring
- Multilayer and Biomimetic Polycaprolactone/Uterine ECM Scaffold for Uterine Tissue Engineering and Anti-Adhesion Barrier Applications via 3D-Printing Near-Field Melt Electrowriting
- HelixWings enables AI-driven enzyme engineering for biomimetic cofactor utilization
- Fibronectin-Assisted Coating of Low-Molecular-Weight Fucoidan Creates a Biomimetic Interface for Endothelialization of Cobalt-Chromium Stents
- Performance of Rilpivirine-Based Hydrophobic Tags and PROTACs Directed Against HIV-1 Reverse Transcriptase
BibTeX
@article{xiao2026biomimetic,
title = {{Biomimetic hydrophobic gating in MXene polypyrrole–based artificial Ion channels for efficient perchlorate sensing}},
author = {Jiaxin Xiao and Lingjun Bu and Yangtao Wu and Shiqing Zhou and Sheng Xie and Zebing Zeng},
journal = {Nature Communications},
year = {2026},
month = oct,
doi = {10.1038/s41467-026-79217-x},
url = {https://www.nature.com/articles/s41467-026-79217-x},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Biomimetic hydrophobic gating in MXene polypyrrole–based artificial Ion channels for efficient perchlorate sensing
AU - Jiaxin Xiao
AU - Lingjun Bu
AU - Yangtao Wu
AU - Shiqing Zhou
AU - Sheng Xie
AU - Zebing Zeng
PY - 2026
DA - 2026/10/28
JO - Nature Communications
DO - 10.1038/s41467-026-79217-x
UR - https://www.nature.com/articles/s41467-026-79217-x
AB - Ion selective electrodes represent a promising approach for ion detection based on potentiometric sensing principle. However, their practical application is often hampered by insufficient selectivity, primarily caused by interference from structurally similar ions. Herein, inspired by biological potassium ion channels, we demonstrate an efficient perchlorate ion selective electrode via the self–assembly of pyrrole–functionalized MXene nanosheets and methylated quaternary ammonium compounds. The resulting composite sensor significantly outperforms commercial ion selective electrodes with a > 10 ⁴ –fold lower detection limit (10 –9.7 M), 18–fold higher selectivity ( K ij of 130.4), and a maximum sensitivity up to 59.6 mV/dec for perchlorate. Synchrotron X–ray scattering and mechanistic studies attribute this superior performance to a hydrophobic gating mechanism arising from dehydration effects and transport resistance within confined channels, which effectively lowers the energy barrier for perchlorate transport by 12.13 kcal/mol compared to that of sulfate. Furthermore, the sensor was optimized via substituent engineering for broad-spectrum anion detection and integrated into a portable platform for continuous on–site monitoring, achieving accuracy comparable to ion chromatography in real–world scenarios.
SN - 2041-1723
ER -