Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 9 min ago
Peer-reviewedCC BY 4.0Diagnostics

Multi-Reference Evaluation of Deep Learning Tumour Segmentation in Multi-Sequence Nasopharyngeal Carcinoma MRI

  1. 1Faculty of Computer Science and Engineering, Ss. Cyril and Methodius University in Skopje, 1000 Skopje, North Macedonia; (M.P.); (I.C.); (I.K.); (A.S.); (D.T.)

Abstract

Background/Objectives: Deep learning segmentation of nasopharyngeal carcinoma is usually reported as one Dice similarity coefficient (DSC) against one reference mask, although multi-sequence MRI is often delineated separately on each sequence. We aimed to quantify how far the choice of reference changes reported performance, and to compare this with the disagreement between radiologists. Methods: We analysed a public dataset of 277 patient records with separately delineated T1-weighted, T2-weighted and contrast-enhanced T1-weighted MRI, 30 of whom were annotated by two radiologists. Tumour volumes were compared without registration. Spatial agreement was measured after rigid registration, with the loss from transferring masks between acquisition grids estimated separately. nnU-Net models were scored against every reference, including the second radiologist’s, in 102 held-out patient records. Results: Without registration, the sequence effect on tumour volume was 10.9%, against a reader effect of 5.7% (ratio 1.9, 95% CI 1.40 to 2.49). After rigid registration, per-sequence references agreed at a median DSC of 0.783, against 0.898 between radiologists; in the double-annotated patient records, the paired gap narrowed only from 0.129 to 0.083 (95% CI 0.063 to 0.111) when grid transfer was matched. One fixed set of predictions scored 0.726, 0.685 and 0.673, depending only on the reference (median per-patient reference spread 0.075), and switching the reference sequence moved scores 2.7 to 3.6 times as much as switching the radiologist. Conclusions: Part of the cross-sequence difference is a difference in what each sequence makes visible rather than annotation error, so a single-reference DSC on multi-sequence data depends on a rarely stated choice. Performance should be reported against every available reference and read against measured inter-reader agreement.

Related

  1. Prognostic evaluation of stage I-IVa nasopharyngeal carcinoma: integrating PET/CT parameters, inflammatory and clinical features
    Yuhu Lv, Danzha Zheng, Zhangyongxue Zhou +5
    BMC CancerPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Quantitative evaluation of salivary gland structural and microvascular alterations after chemoradiotherapy in nasopharyngeal carcinoma using SWE and UMAI.
    Hamit Basaran, Nusret Seher, Burak Deli +7
    Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyPeer-reviewedCC BY-NC-NDFull textPhysiologyEurope PMCPMC
  3. Multi‐Sequence Fusion MRI Deep Learning Models for Discrimination of Recurrent Nasopharyngeal Carcinoma and Osteoradionecrosis
    Wen‐Tao Gong, Xue‐Li Liu, Xiao Chen +9
    World Journal of Otorhinolaryngology-Head and Neck SurgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  4. Integrating multi-region radiomic features for pre-radiotherapy prediction of severe radiation-induced oral mucositis: a high-performance machine learning model for nasopharyngeal carcinoma
    Xiadong Li, Yanjiao Mao, Xiaoju Wang
    Frontiers in OncologyPeer-reviewedCC BY 4.0OncologyFrontiersCrossref
  5. Evaluation of the Position of Impacted Maxillary Canines on Panoramic Radiographs Using Deep Learning with CBCT as the Reference Standard
    Anıl Demirel, Sabahattin Bor, Fırat Oğuz +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{pandilova2026multireference,
  title = {{Multi-Reference Evaluation of Deep Learning Tumour Segmentation in Multi-Sequence Nasopharyngeal Carcinoma MRI}},
  author = {Ema Pandilova and Marko Petrov and Ivan Chorbev and Ivan Kitanovski and Aleksandar Stojmenski and Dimitar Trajanov},
  journal = {Diagnostics},
  year = {2026},
  month = nov,
  doi = {10.3390/diagnostics16213632},
  url = {https://doi.org/10.3390/diagnostics16213632},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Multi-Reference Evaluation of Deep Learning Tumour Segmentation in Multi-Sequence Nasopharyngeal Carcinoma MRI
AU  - Ema Pandilova
AU  - Marko Petrov
AU  - Ivan Chorbev
AU  - Ivan Kitanovski
AU  - Aleksandar Stojmenski
AU  - Dimitar Trajanov
PY  - 2026
DA  - 2026/11/03
JO  - Diagnostics
DO  - 10.3390/diagnostics16213632
UR  - https://doi.org/10.3390/diagnostics16213632
AB  - Background/Objectives: Deep learning segmentation of nasopharyngeal carcinoma is usually reported as one Dice similarity coefficient (DSC) against one reference mask, although multi-sequence MRI is often delineated separately on each sequence. We aimed to quantify how far the choice of reference changes reported performance, and to compare this with the disagreement between radiologists. Methods: We analysed a public dataset of 277 patient records with separately delineated T1-weighted, T2-weighted and contrast-enhanced T1-weighted MRI, 30 of whom were annotated by two radiologists. Tumour volumes were compared without registration. Spatial agreement was measured after rigid registration, with the loss from transferring masks between acquisition grids estimated separately. nnU-Net models were scored against every reference, including the second radiologist’s, in 102 held-out patient records. Results: Without registration, the sequence effect on tumour volume was 10.9%, against a reader effect of 5.7% (ratio 1.9, 95% CI 1.40 to 2.49). After rigid registration, per-sequence references agreed at a median DSC of 0.783, against 0.898 between radiologists; in the double-annotated patient records, the paired gap narrowed only from 0.129 to 0.083 (95% CI 0.063 to 0.111) when grid transfer was matched. One fixed set of predictions scored 0.726, 0.685 and 0.673, depending only on the reference (median per-patient reference spread 0.075), and switching the reference sequence moved scores 2.7 to 3.6 times as much as switching the radiologist. Conclusions: Part of the cross-sequence difference is a difference in what each sequence makes visible rather than annotation error, so a single-reference DSC on multi-sequence data depends on a rarely stated choice. Performance should be reported against every available reference and read against measured inter-reader agreement.
SN  - 2075-4418
ER  -