The Prediction of the Concentration of Artificially Added Microplastics in Different Foods and Feed Ingredients Using Near-Infrared Spectroscopy—Instrument Type, Limit of Detection and Quantification
- 1Centre for Nutrition and Food Sciences, Queensland Alliance for Agriculture and Food Innovation (QAAFI), The University of Queensland, Brisbane, QLD 4072, Australia (L.C.H.)
- 2School of Agriculture and Food Sustainability (AGFS), The University of Queensland, Brisbane, QLD 4072, Australia
Abstract
Predicting microplastic (MP) concentrations in different foods and feed ingredients is a growing area of interest in near-infrared (NIR) spectroscopy. The objective of this paper is to evaluate the ability of NIR spectroscopy (benchtop and portable instruments) to predict the concentration (0% to 5% w/w) of the addition of polymers [polyethylene (PE), polypropylene (PP), and polyethylene terephthalate (PET)] into three different matrices commonly encountered as food and feed ingredients. This study used samples of banana, spinach, breadcrumbs, and black soldier fly larvae (BSFL) meal with different levels of polymer addition. Calibration models to predict the concentration of MP in the samples were developed using partial least squares (PLS) regression. The coefficient of determination in cross-validation (R2CV) and the standard error in cross-validation (SECV) were 0.76 and 0.72%, and 0.81 and 0.75% using cross-validation (CV) and the test set, respectively. Using CV and the test set, the R2CV and SECV were 0.92 (SECV: 0.38%) and 0.95 (SECV: 0.32%), respectively, for the portable instrument. The R2CV and SECV were 0.81 (SECV: 0.59%) and 0.81 (SECV: 0.60%) for the CV and test sets analysed using the benchtop instrument, respectively. The SEP was 0.41% and 0.65% using the portable and benchtop instruments, respectively. These results demonstrate the potential of both portable and benchtop NIR spectroscopy as rapid tools for predicting microplastic concentrations in a range of food and feed matrices.
Related
- Real-time monitoring of breath methane concentration in dairy cows using tunable diode laser spectroscopy and facemask-based sampling
- Retrieval of Two-Dimensional Size Distribution and Concentration of SiO2@Au Core–Shell Nanospheres by Extinction Spectroscopy
- In-situ quantification of NH₂ radicals in low-pressure NH3/O2/N2 flames implementing cavity ring-down spectroscopy: Challenges & mitigation
- Explainable residual CNN with Gramian Angular Field encoding for rapid quantification of soil properties using near-infrared spectroscopy
- Artificially intelligent modeling of macromolecular assemblies
BibTeX
@article{cozzolino2026prediction,
title = {{The Prediction of the Concentration of Artificially Added Microplastics in Different Foods and Feed Ingredients Using Near-Infrared Spectroscopy—Instrument Type, Limit of Detection and Quantification}},
author = {Daniel Cozzolino and Adam Kolobaric and Shanmugam Alagappan and Joseph Robert Nastasi and Louwrens C. Hoffman},
journal = {Foods},
year = {2026},
month = oct,
doi = {10.3390/foods15213857},
url = {https://doi.org/10.3390/foods15213857},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - The Prediction of the Concentration of Artificially Added Microplastics in Different Foods and Feed Ingredients Using Near-Infrared Spectroscopy—Instrument Type, Limit of Detection and Quantification
AU - Daniel Cozzolino
AU - Adam Kolobaric
AU - Shanmugam Alagappan
AU - Joseph Robert Nastasi
AU - Louwrens C. Hoffman
PY - 2026
DA - 2026/10/28
JO - Foods
DO - 10.3390/foods15213857
UR - https://doi.org/10.3390/foods15213857
AB - Predicting microplastic (MP) concentrations in different foods and feed ingredients is a growing area of interest in near-infrared (NIR) spectroscopy. The objective of this paper is to evaluate the ability of NIR spectroscopy (benchtop and portable instruments) to predict the concentration (0% to 5% w/w) of the addition of polymers [polyethylene (PE), polypropylene (PP), and polyethylene terephthalate (PET)] into three different matrices commonly encountered as food and feed ingredients. This study used samples of banana, spinach, breadcrumbs, and black soldier fly larvae (BSFL) meal with different levels of polymer addition. Calibration models to predict the concentration of MP in the samples were developed using partial least squares (PLS) regression. The coefficient of determination in cross-validation (R2CV) and the standard error in cross-validation (SECV) were 0.76 and 0.72%, and 0.81 and 0.75% using cross-validation (CV) and the test set, respectively. Using CV and the test set, the R2CV and SECV were 0.92 (SECV: 0.38%) and 0.95 (SECV: 0.32%), respectively, for the portable instrument. The R2CV and SECV were 0.81 (SECV: 0.59%) and 0.81 (SECV: 0.60%) for the CV and test sets analysed using the benchtop instrument, respectively. The SEP was 0.41% and 0.65% using the portable and benchtop instruments, respectively. These results demonstrate the potential of both portable and benchtop NIR spectroscopy as rapid tools for predicting microplastic concentrations in a range of food and feed matrices.
SN - 2304-8158
ER -