Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 26 min ago
PreprintCC BYmedRxiv

Calibration and processing sensitivity of time-embedded three-dimensional electrocardiographic descriptors: a two-dataset benchmark

  1. 1Riojan Health Service

Abstract

Time-embedded electrocardiographic descriptors combine high-order derivatives in nonlinear ratios, making their numerical calibration essential. We analyzed 200 LUDB participants (1,748 QRS windows) and a fixed external sample of 1,000 PTB-XL participants (9,735 windows). Four prespecified derivative operators were evaluated at three nominal Butterworth cutoffs; a fifth, regularized operator was added post hoc. Extensions added transfer functions, matched response crossings and a Gaussian transient with exact derivatives. The expanded calibration comprised 1,005 mathematical signal/noise realizations. At 150 Hz, spectral differentiation (SPEC) increased external participant-level mean absolute torsion by a median 78.97% relative to successive finite differences (FD; 95% confidence interval 77.39-80.53). Reducing the cutoff to 40 Hz yielded weak rank preservation: Spearman correlations were 0.045 for SPEC and 0.099 for FD. Matching each derivatives first normalized -3-dB crossing at 20 Hz reduced the external SPEC-FD median difference to 0.016%, but introduced 4.26-4.70% noiseless error on the Gaussian transient. Agreement was therefore not accuracy against the known target. For the Gaussian transient with 20-microvolt noise, relative root mean squared errors at 150 Hz were 719.52% for SPEC and 99.96% for the regularizer; the latter error remained comparable to the target magnitude, and regularization also introduced noiseless bias. Almost-curvature approximated a normalized voltage slope under the specified coordinates and did not converge to classical curvature under reparametrization. Explicit transfer functions, absolute descriptor levels and analytic targets explain important processing effects while separating numerical agreement from clinical validity. No universally optimal estimator or diagnostic benefit is established.

Related

  1. A twin study of genetic and environmental aetiologies of associations between sensory processing sensitivity and psychotic-like experiences
    Marloes Mak, Angelica Ronald, Corina Greven +1
    PsyArXivPreprintAll rights reservedFull textPsychiatry & mental healthOSF
  2. Context processing as a moderator of the association between posttraumatic stress symptoms and the adaptation of maternal sensitivity following stress related to separation.
    Shannen Graf, Lara Detoledo, Sophie Wood +3
    Infant mental health journalPeer-reviewedCC BYFull textPsychiatry & mental healthEurope PMC
  3. Real-time assessment of temperature sensitivity, pain processing, and pain behavior across the lifespan: Integrating stimulus data, contact force, and subjective ratings.
    Heinz-Jürgen Steinhoff, Besim Prenaj, Sebastian L Kübel +1
    Behavior research methodsPeer-reviewedCC BYFull textPhysiologyEurope PMC
  4. Three-dimensional in vitro models for assessing temozolomide sensitivity in glioblastoma
    Andresa Hiromi Sakai, Marna Eliana Sakalem, Luiza Magosso Oliveira Rocha +7
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textHuman geneticsCrossrefPMC
  5. Risk of atrial fibrillation according to electrocardiographic risk factors: a nationwide cohort study of 1.5 million patients
    European heart journal openPeer-reviewedCC BY-NCFull textCardiovascular medicineEurope PMC
BibTeX
@misc{valdes2026calibration,
  title = {{Calibration and processing sensitivity of time-embedded three-dimensional electrocardiographic descriptors: a two-dataset benchmark}},
  author = {A. J. Bermejo Valdes},
  howpublished = {medRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.14.26363023},
  url = {https://www.medrxiv.org/content/10.64898/2026.09.14.26363023v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Calibration and processing sensitivity of time-embedded three-dimensional electrocardiographic descriptors: a two-dataset benchmark
AU  - A. J. Bermejo Valdes
PY  - 2026
DA  - 2026/09/14
PB  - medRxiv
DO  - 10.64898/2026.09.14.26363023
UR  - https://www.medrxiv.org/content/10.64898/2026.09.14.26363023v1
AB  - Time-embedded electrocardiographic descriptors combine high-order derivatives in nonlinear ratios, making their numerical calibration essential. We analyzed 200 LUDB participants (1,748 QRS windows) and a fixed external sample of 1,000 PTB-XL participants (9,735 windows). Four prespecified derivative operators were evaluated at three nominal Butterworth cutoffs; a fifth, regularized operator was added post hoc. Extensions added transfer functions, matched response crossings and a Gaussian transient with exact derivatives. The expanded calibration comprised 1,005 mathematical signal/noise realizations. At 150 Hz, spectral differentiation (SPEC) increased external participant-level mean absolute torsion by a median 78.97% relative to successive finite differences (FD; 95% confidence interval 77.39-80.53). Reducing the cutoff to 40 Hz yielded weak rank preservation: Spearman correlations were 0.045 for SPEC and 0.099 for FD. Matching each derivatives first normalized -3-dB crossing at 20 Hz reduced the external SPEC-FD median difference to 0.016%, but introduced 4.26-4.70% noiseless error on the Gaussian transient. Agreement was therefore not accuracy against the known target. For the Gaussian transient with 20-microvolt noise, relative root mean squared errors at 150 Hz were 719.52% for SPEC and 99.96% for the regularizer; the latter error remained comparable to the target magnitude, and regularization also introduced noiseless bias. Almost-curvature approximated a normalized voltage slope under the specified coordinates and did not converge to classical curvature under reparametrization. Explicit transfer functions, absolute descriptor levels and analytic targets explain important processing effects while separating numerical agreement from clinical validity. No universally optimal estimator or diagnostic benefit is established.
ER  -