Hypnodensity sleep metrics from fingertip photoplethysmography are better associated with daytime sleepiness and fatigue than traditional metrics from polysomnography

Abstract

BACKGROUND: Traditional sleep metrics from polysomnography are often limited by the hypnogram, in which each 30-s epoch is classified into one of the five sleep stages. This oversimplifies sleep stage continuity and fragmented sleep, typical in sleep-disordered breathing (SDB). Deep learning offers more dynamic sleep modelling with a higher temporal resolution by providing probabilities for each sleep stage, known as hypnodensities. RESEARCH QUESTION AND METHODS: We investigated whether high-frequency (1/s) hypnodensities captured from nocturnal fingertip photoplethysmography (PPG) recordings better correlate with patient-reported outcomes in SDB than traditional metrics. RESULTS: Among 2,280 patients (65% male, mean age 62 years, mean apnoea-hypopnoea index (AHI) 23.5/h), we found that several PPG-derived hypnodensity metrics correlate with self-reported daytime fatigue and sleepiness. The level of correlation was better or similar compared to traditional hypnogram-based sleep metrics derived from manually scored polysomnography. Specifically, PPG-based hypnodensities for N1 and N3 sleep showed a stronger association (p < 0.005) with fatigue and sleepiness than manually scored N1 and N3 sleep. Multivariable logistic regression (adjusted for age, sex, body mass index, AHI, and total sleep time below 90% blood oxygen saturation) revealed significant associations (p < 0.01) between multiple PPG-based hypnodensity metrics and daytime sleepiness. CONCLUSION: These findings suggest that PPG-based hypnodensities improve the characterisation of sleep quality and better predict patient-reported outcomes in SDB patients. Future uses may include tracking sleep quality with fingertip pulse oximeters outside of sleep centres, potentially over multiple nights due to their simplicity.

Related

  1. Excessive daytime sleepiness and associated factors among commercial vehicle drivers in Jimma Zone, Southwest Ethiopia
    Hiwot Berhanu, Wondu Reta, Moyeta Bariso +4
    Sleep Science and PracticePeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Time-step level sleep apnea detection using LSTM with adaptive thresholding in polysomnography
    Dongwon Woo, Sangwook Kim, Sungmoon Jeong +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPhysiologyCrossref
  3. Sleep Quality and Daytime Sleepiness in Patients with Chronic Obstructive Pulmonary Disease in a Tertiary Care Hospital: An Observational Study
    S. Jha, A. Suwal, B. Shah +1
    medRxivPreprintAll rights reservedFull textGeneral medicinemedRxiv
  4. Traditional Chinese Medicine-Associated Bioactive Hydrogels: Material Roles, Network Design, and Therapeutic Applications.
    Zile Song, Jiafei Chen, Chun Pu +7
    Gels (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Long-term changes in subjective daytime sleepiness following tonsillectomy and uvulopalatopharyngoplasty (UPPP) : A prospective cohort study
    Przemysław Bant, Aleksander Julian Jurkiewicz, Kornel Szczygielski +3
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{rusanen2026hypnodensity,
  title = {{Hypnodensity sleep metrics from fingertip photoplethysmography are better associated with daytime sleepiness and fatigue than traditional metrics from polysomnography}},
  author = {Matias Rusanen and Viateur Tuyinsenge and Sandrine Muller and Renaud Tamisier and Sébastien Baillieul and Sami Myllymaa and Samu Kainulainen and Timo Leppänen and Jean-Louis Pepin and Sébastien Bailly},
  journal = {Pulmonology},
  year = {2026},
  month = jun,
  doi = {10.1080/25310429.2026.2683326},
  url = {https://hal.science/hal-05744213v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Hypnodensity sleep metrics from fingertip photoplethysmography are better associated with daytime sleepiness and fatigue than traditional metrics from polysomnography
AU  - Matias Rusanen
AU  - Viateur Tuyinsenge
AU  - Sandrine Muller
AU  - Renaud Tamisier
AU  - Sébastien Baillieul
AU  - Sami Myllymaa
AU  - Samu Kainulainen
AU  - Timo Leppänen
AU  - Jean-Louis Pepin
AU  - Sébastien Bailly
PY  - 2026
DA  - 2026/06/12
JO  - Pulmonology
DO  - 10.1080/25310429.2026.2683326
UR  - https://hal.science/hal-05744213v1
AB  - BACKGROUND: Traditional sleep metrics from polysomnography are often limited by the hypnogram, in which each 30-s epoch is classified into one of the five sleep stages. This oversimplifies sleep stage continuity and fragmented sleep, typical in sleep-disordered breathing (SDB). Deep learning offers more dynamic sleep modelling with a higher temporal resolution by providing probabilities for each sleep stage, known as hypnodensities. RESEARCH QUESTION AND METHODS: We investigated whether high-frequency (1/s) hypnodensities captured from nocturnal fingertip photoplethysmography (PPG) recordings better correlate with patient-reported outcomes in SDB than traditional metrics. RESULTS: Among 2,280 patients (65% male, mean age 62 years, mean apnoea-hypopnoea index (AHI) 23.5/h), we found that several PPG-derived hypnodensity metrics correlate with self-reported daytime fatigue and sleepiness. The level of correlation was better or similar compared to traditional hypnogram-based sleep metrics derived from manually scored polysomnography. Specifically, PPG-based hypnodensities for N1 and N3 sleep showed a stronger association (p < 0.005) with fatigue and sleepiness than manually scored N1 and N3 sleep. Multivariable logistic regression (adjusted for age, sex, body mass index, AHI, and total sleep time below 90% blood oxygen saturation) revealed significant associations (p < 0.01) between multiple PPG-based hypnodensity metrics and daytime sleepiness. CONCLUSION: These findings suggest that PPG-based hypnodensities improve the characterisation of sleep quality and better predict patient-reported outcomes in SDB patients. Future uses may include tracking sleep quality with fingertip pulse oximeters outside of sleep centres, potentially over multiple nights due to their simplicity.
SN  - 2531-0429
SN  - 2531-0437
ER  -