Skip to content
DraconiticResearch
Search Sources API
197,787 studies31 sourcesUpdated 58 min ago
Peer-reviewedCC BYWorld journal of urology

Optical characterization of endoscopes for StoneSense™ compatibility.

1 more authors
12 affiliations
  1. 1Service d'urologie, Tenon Hôpital, 4 Rue de la Chine, 75020, Paris, France. [email protected].
  2. 2GRC20 - Endolase lab, Sorbonne University, PIMM-Arts et Métiers Paris Tech, F-75013, Paris, France. [email protected].
  3. 3PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, 151 bd de l'Hôpital, F-75013, Paris, France. [email protected].
  4. 4Department of Urology, University of Modena and Reggio Emilia, 41121, Modena, Italy. [email protected].
  5. 5Service d'urologie, Tenon Hôpital, 4 Rue de la Chine, 75020, Paris, France.
  6. 6GRC20 - Endolase lab, Sorbonne University, PIMM-Arts et Métiers Paris Tech, F-75013, Paris, France.
  7. 7PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, 151 bd de l'Hôpital, F-75013, Paris, France.
  8. 8Department of Experimental Oncology/Unit of Urology, URI, IRCCS Ospedale San Raffaele, Milan, Italy.
  9. 9Vita-Salute San Raffaele University, Milan, Italy.
  10. 10Department of Urology, Poitiers University Hospital, 2 Rue de la Milétrie, 86000, Poitiers, France.
  11. 11Service d'Urologie, Centre Hospitalier Universitaire de Limoges, 2 avenue Martin Luther King, 87000, Limoges, France.
  12. 12Research and Development, IPG Medical, Marlborough, MA, USA.

Abstract

Background and objective

The StoneSense Module (SSM), integrated within IPG laser lithotripsy systems, uses endoscopic white-light illumination for real-time stone-tissue discrimination, enabling conditional laser firing only in the presence of a confirmed calculus. SSM performance depends on the endoscope's optical output falling within defined thresholds. We aimed to characterize commercially available flexible ureteroscopes and cystoscopes against predefined SSM compatibility criteria.Methods

Twenty device-videobox combinations (15 flexible ureteroscopes, 4 cystoscopes, 1 semirigid ureteroscope; 7 manufacturers) with complete StoneSense-processed band data were included. Total power and spectral band power (Bands 1-3) were measured at three brightness levels in free-space configuration (no fiber inserted), and temporal profile was classified by oscilloscopy. Per-fiber band power was modeled from these free-space measurements, not measured with the fiber in the working channel. Predicted SSM band-power compatibility was assessed per device-brightness-fiber combination against predefined thresholds, with a minimum PWM frequency of 2 kHz as the temporal criterion.Results

All 20 devices exhibited continuous-wave (CW) emission, conferring unconditional temporal SSM compatibility. Following recalibration of the SSM reference thresholds, the 200 µm and 365 µm fibers were predicted to meet SSM band power thresholds at medium/maximum brightness for 18 of the 20 devices, with the Karl Storz Flex XC and the Olympus CYF-VH cystoscope as the two exceptions at both fiber sizes. Additional saturation, restricted to the 550 µm and 940 µm fibers, was identified for six further devices (Table 1). Four Olympus platforms showed modeled sub-threshold power at minimum brightness. Four illumination archetypes were identified: blue-pump LED, red-shifted LED, Olympus intermediate LED, and LED-phosphor.Conclusions

The 200 µm and 365 µm fibers provide the broadest predicted compatibility (18/20 platforms), with the Flex XC and CYF-VH as the exceptions. Predicted incompatibilities are otherwise device-architecture-driven and manageable through fiber and brightness selection. A device-level compatibility reference matrix based on modeled estimates is provided.

Related

  1. Microbiological surveillance after automated reprocessing of gastrointestinal endoscopes in routine clinical practice: A prospective randomized microbiological surveillance study
    Masayuki Kato, Hideki Hayashi, Nobuharu Hironaka +6
    PLOS OnePeer-reviewedCC BY 4.0Full textMicrobiologyEpidemiology & public healthPLOS
  2. Automated segmentation and clinical characterization of layered plaque in intracoronary optical coherence tomography
    Ruben G.A. van der Waerden, Joske L. van der Zande, Simone Saitta +23
    International journal of cardiology. Heart & vasculaturePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Breaking the compatibility barrier: cholangioscopy-guided laser lithotripsy during enteroscopy-assisted endoscopic retrograde cholangiopancreatography in Roux-en-Y anatomy.
    Alda Andrade, Ana Rita Ribeiro, Jorge Bezerra +4
    EndoscopyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. cPRArgentina: a population-specific cPRA calculator incorporating optional ABO compatibility
    Manuel Quirno Costa, María Belén Balekjian, María Soledad Paulos +1
    Frontiers in geneticsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMCEurope PMC
  5. Demonstration of a compatibility-based childcare support service using quantum annealing
    Yuuma Matsumoto, Taisei Takabayashi, Rima Sato +2
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{nannola2026optical,
  title = {{Optical characterization of endoscopes for StoneSense™ compatibility.}},
  author = {Nicola Nannola and Carlos Gonzalez-Gonzalez and Federico Zorzi and Pietro Scilipoti and Adèle Martin-Illac and Frédéric Panthier and Marie Chicaud and Steeve Doizi and Iliya Yaroslavsky and Anastasia Kovalenko and James Childs and Igor Perchuk and Olivier Traxer},
  journal = {World journal of urology},
  year = {2026},
  month = nov,
  doi = {10.1007/s00345-026-06845-9},
  url = {https://europepmc.org/article/MED/42970098},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Optical characterization of endoscopes for StoneSense™ compatibility.
AU  - Nicola Nannola
AU  - Carlos Gonzalez-Gonzalez
AU  - Federico Zorzi
AU  - Pietro Scilipoti
AU  - Adèle Martin-Illac
AU  - Frédéric Panthier
AU  - Marie Chicaud
AU  - Steeve Doizi
AU  - Iliya Yaroslavsky
AU  - Anastasia Kovalenko
AU  - James Childs
AU  - Igor Perchuk
AU  - Olivier Traxer
PY  - 2026
DA  - 2026/11/02
JO  - World journal of urology
DO  - 10.1007/s00345-026-06845-9
UR  - https://europepmc.org/article/MED/42970098
AB  - Background and objective  The StoneSense Module (SSM), integrated within IPG laser lithotripsy systems, uses endoscopic white-light illumination for real-time stone-tissue discrimination, enabling conditional laser firing only in the presence of a confirmed calculus. SSM performance depends on the endoscope's optical output falling within defined thresholds. We aimed to characterize commercially available flexible ureteroscopes and cystoscopes against predefined SSM compatibility criteria.Methods  Twenty device-videobox combinations (15 flexible ureteroscopes, 4 cystoscopes, 1 semirigid ureteroscope; 7 manufacturers) with complete StoneSense-processed band data were included. Total power and spectral band power (Bands 1-3) were measured at three brightness levels in free-space configuration (no fiber inserted), and temporal profile was classified by oscilloscopy. Per-fiber band power was modeled from these free-space measurements, not measured with the fiber in the working channel. Predicted SSM band-power compatibility was assessed per device-brightness-fiber combination against predefined thresholds, with a minimum PWM frequency of 2 kHz as the temporal criterion.Results  All 20 devices exhibited continuous-wave (CW) emission, conferring unconditional temporal SSM compatibility. Following recalibration of the SSM reference thresholds, the 200 µm and 365 µm fibers were predicted to meet SSM band power thresholds at medium/maximum brightness for 18 of the 20 devices, with the Karl Storz Flex XC and the Olympus CYF-VH cystoscope as the two exceptions at both fiber sizes. Additional saturation, restricted to the 550 µm and 940 µm fibers, was identified for six further devices (Table 1). Four Olympus platforms showed modeled sub-threshold power at minimum brightness. Four illumination archetypes were identified: blue-pump LED, red-shifted LED, Olympus intermediate LED, and LED-phosphor.Conclusions  The 200 µm and 365 µm fibers provide the broadest predicted compatibility (18/20 platforms), with the Flex XC and CYF-VH as the exceptions. Predicted incompatibilities are otherwise device-architecture-driven and manageable through fiber and brightness selection. A device-level compatibility reference matrix based on modeled estimates is provided.
SN  - 0724-4983
SN  - 1433-8726
ER  -