Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 56 min ago
PreprintarXiv licencearXiv

Separating active irradiation from passive outcome learning in radiotherapy: a finite-model computational benchmark

Abstract

Apparent gains from informative irradiation may reflect treatment reoptimization or better use of outcomes from static treatment. We tested whether changing irradiation adds value beyond optimized static treatment, passive outcome learning, and data-dependent stopping. Three synthetic three-dimensional geometries supplied 51 parent fluences. Four known response scenarios generated Bernoulli risks from normalized organ-dose contrasts at uncalibrated slopes of 0, 4, 16, and 64; one unknown scenario applied to all 2,816 hypothetical uses. Loss included acquisition and deployment. We compared fixed passive and locally selected fixed active sampling, passive optimal stopping, and a restricted one-checkpoint, one-switch active policy with a shared terminal menu. Fixed active sampling improved on fixed passive sampling in three of nine nonzero-slope conditions, but never on passive stopping. One-switch adaptation added at most 4.00625e-5 expected model events avoided. With the policies held fixed, two of four increments above the numerical reporting threshold reversed sign under alternative integration; all four became negative at some allowed prior weighting. Adding three generated probes changed none of 72 paired policy values, and none was used on a positive-probability path. The tested probes did not demonstrate stable incremental value beyond optimized passive stopping. Treatment opportunities, stopping permissions, acquisition costs, and input sensitivity must be separated when attributing benefits to active irradiation. These are restricted finite-model results, not evidence about unrestricted active learning or clinical safety and effectiveness.

Related

  1. OpenGray: a benchmark for evaluating the decisions of radiotherapy planning agents
    Humza Nusrat, Kundan Thind
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  2. Computational Fluid Dynamics and Discrete Dipole Approximation Applied to Predict Airborne Viruses Disinfection by Ultraviolet Irradiation
    Talib Dbouk, Maxim Yurkin
    arXivPreprintCC BY-NC-ND 4.0Full textComputational physicsFluid dynamicsarXiv
  3. DoseRAD2026: A benchmark dataset for AI‐accelerated photon and proton dose calculation in radiotherapy
    Fan Xiao, Nikolaos Delopoulos, Niklas Wahl +13
    Medical PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMCEurope PMC
  4. Separating charm and bottom decay electrons with point-cloud deep learning on the charged-hadron environment
    Jingyu Zhang, Wanbing He, Long Ma
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsarXiv
  5. MLIP Detective: Active Failure Mode Discovery Beyond Benchmark Scores for Machine-Learning Interatomic Potentials
    Ryuhei Okuno, Nontawat Charoenphakdee, Kaoru Hisama +1
    arXivPreprintCC BY 4.0Full textPhysical chemistryCondensed matterarXiv
BibTeX
@misc{wang2026separating,
  title = {{Separating active irradiation from passive outcome learning in radiotherapy: a finite-model computational benchmark}},
  author = {Yuntao Wang},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.14222},
  eprint = {2610.14222},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.14222},
}
RIS
TY  - UNPB
TI  - Separating active irradiation from passive outcome learning in radiotherapy: a finite-model computational benchmark
AU  - Yuntao Wang
PY  - 2026
DA  - 2026/10/09
PB  - arXiv
DO  - 10.48550/arxiv.2610.14222
UR  - https://arxiv.org/abs/2610.14222
AB  - Apparent gains from informative irradiation may reflect treatment reoptimization or better use of outcomes from static treatment. We tested whether changing irradiation adds value beyond optimized static treatment, passive outcome learning, and data-dependent stopping. Three synthetic three-dimensional geometries supplied 51 parent fluences. Four known response scenarios generated Bernoulli risks from normalized organ-dose contrasts at uncalibrated slopes of 0, 4, 16, and 64; one unknown scenario applied to all 2,816 hypothetical uses. Loss included acquisition and deployment. We compared fixed passive and locally selected fixed active sampling, passive optimal stopping, and a restricted one-checkpoint, one-switch active policy with a shared terminal menu. Fixed active sampling improved on fixed passive sampling in three of nine nonzero-slope conditions, but never on passive stopping. One-switch adaptation added at most 4.00625e-5 expected model events avoided. With the policies held fixed, two of four increments above the numerical reporting threshold reversed sign under alternative integration; all four became negative at some allowed prior weighting. Adding three generated probes changed none of 72 paired policy values, and none was used on a positive-probability path. The tested probes did not demonstrate stable incremental value beyond optimized passive stopping. Treatment opportunities, stopping permissions, acquisition costs, and input sensitivity must be separated when attributing benefits to active irradiation. These are restricted finite-model results, not evidence about unrestricted active learning or clinical safety and effectiveness.
ER  -