Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 35 min ago
PreprintCC BYbioRxiv

Residual Hearing Loss After Chronic Cochlear Implantation in Guinea Pigs is Primarily Conductive

  1. 1Oregon Health & Science University

Abstract

It is desirous to preserve residual low-frequency hearing in cochlear implant recipients, as dual stimulation using electrical and acoustic signals results in superior speech-in-noise processing and musicality. However, cochlear implant recipients commonly lose their residual acoustic hearing gradually following surgical placement of the array. The governing mechanism is not understood and is likely due to multiple factors including surgical trauma, inflammation, and the foreign body induced immune response to the array, including formation of intracochlear fibrosis. Normal mechanical function of the cochlea is expected to underpin residual hearing but has not been directly studied. This function includes efficient transmission of sound to the cochlea via the middle ear, sound propagation via the basilar membrane travelling wave, mechanical tuning characteristics, and the non-linear cochlear amplification of responses to low-frequency stimulation. Here, we examined these features in cochleae and middle ears of unimplanted, acutely and chronically implanted guinea pigs using our minimally invasive preparation and optical coherence tomography vibrometry. We observed that mechanical tuning and amplification is not significantly altered by either acute or chronic implant. However, the response threshold was raised and proportional to middle ear responses. Additionally, the organ of Corti phase, and its sound intensity dependent changes, are unaltered by CI. Finally, a cluster analysis revealed sensitivity loss in chronically implanted animals is caused by middle ear dysfunction. Hence, in the guinea pig model, the dominant etiology of residual hearing loss is conductive. More research is required to establish whether residual hearing loss in humans similarly shares conductive elements.

Related

  1. Dietary Zinc Glycine Supplementation Attenuates Aging-Driven Cochlear Hair Cell Oxidative Injury and Hearing Loss
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMC
  2. Simultaneous Bilateral Cochlear Implantation in a Child with Warsaw Breakage Syndrome and Normal Cochlear Morphology: A Case Report and Focused Literature Review
    Pinelopi Samara, Michail Athanasopoulos, Nikolaos Markatos +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Tinnitus outcomes after cochlear implantation in single-sided deafness: an exploratory prospective multicenter study
    Jae-Jin Song, Yeonjoo Choi, Yehree Kim +3
    Frontiers in neurologyPeer-reviewedCC BYFull textNeurologyEurope PMC
  4. Optimizing Cochlear Implant Programming in Single‐Sided Deafness and Asymmetric Hearing Loss: A Randomized Comparison of ESRT and Behavioral Methods
    Meredith A. Holcomb, Jennifer Coto, Christina Sarangoulis +4
    Laryngoscope Investigative OtolaryngologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. Clinical Impact of Multiple‐Clip Implantation for Residual Mitral Regurgitation After Transcatheter Edge‐to‐Edge Repair
    Takashi Nagasaka, Vivek Patel, Kazuki Suruga +12
    Journal of the American Heart AssociationPeer-reviewedLicence not statedCardiovascular medicineCrossref
BibTeX
@misc{he2026residual,
  title = {{Residual Hearing Loss After Chronic Cochlear Implantation in Guinea Pigs is Primarily Conductive}},
  author = {W. He and R. Xing and J. D. Hill and E. Porsov and L. J. Reiss and G. W. S. Burwood},
  howpublished = {bioRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.04.763992},
  url = {https://www.biorxiv.org/content/10.64898/2026.11.04.763992v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Residual Hearing Loss After Chronic Cochlear Implantation in Guinea Pigs is Primarily Conductive
AU  - W. He
AU  - R. Xing
AU  - J. D. Hill
AU  - E. Porsov
AU  - L. J. Reiss
AU  - G. W. S. Burwood
PY  - 2026
DA  - 2026/11/04
PB  - bioRxiv
DO  - 10.64898/2026.11.04.763992
UR  - https://www.biorxiv.org/content/10.64898/2026.11.04.763992v1
AB  - It is desirous to preserve residual low-frequency hearing in cochlear implant recipients, as dual stimulation using electrical and acoustic signals results in superior speech-in-noise processing and musicality. However, cochlear implant recipients commonly lose their residual acoustic hearing gradually following surgical placement of the array. The governing mechanism is not understood and is likely due to multiple factors including surgical trauma, inflammation, and the foreign body induced immune response to the array, including formation of intracochlear fibrosis. Normal mechanical function of the cochlea is expected to underpin residual hearing but has not been directly studied. This function includes efficient transmission of sound to the cochlea via the middle ear, sound propagation via the basilar membrane travelling wave, mechanical tuning characteristics, and the non-linear cochlear amplification of responses to low-frequency stimulation. Here, we examined these features in cochleae and middle ears of unimplanted, acutely and chronically implanted guinea pigs using our minimally invasive preparation and optical coherence tomography vibrometry. We observed that mechanical tuning and amplification is not significantly altered by either acute or chronic implant. However, the response threshold was raised and proportional to middle ear responses. Additionally, the organ of Corti phase, and its sound intensity dependent changes, are unaltered by CI. Finally, a cluster analysis revealed sensitivity loss in chronically implanted animals is caused by middle ear dysfunction. Hence, in the guinea pig model, the dominant etiology of residual hearing loss is conductive. More research is required to establish whether residual hearing loss in humans similarly shares conductive elements.
ER  -