Scalpel Versus Geometric Electron Modulation Electrocautery in Thyroid and Parathyroid Surgery: A Randomized Controlled Trial
- 1From the Department of Otolaryngology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Abstract
Background:: Postoperative scarring is an important concern following thyroid and parathyroid surgery. Geometric electron modulation (GEM) electrocautery is designed to reduce tissue injury while providing effective hemostasis. However, evidence regarding its long-term cosmetic outcomes remains limited. This study compares long-term scar quality following cervical incisions created using GEM electrocautery versus a conventional scalpel.
Methods:: In this prospective, randomized, self-controlled trial, 24 patients undergoing thyroidectomy or parathyroidectomy were enrolled. Each half of the cervical incision was randomly assigned to GEM electrocautery or conventional scalpel. Intraoperative blood loss, incision time, and surgical field clarity were recorded. Scar quality was assessed at 2 weeks and at 1, 3, and 12 months using the Thai linear version of the Patient and Observer Scar Assessment Scale. Longitudinal analyses were performed using generalized estimating equations.
Results:: Patient-reported Patient and Observer Scar Assessment Scale scores were significantly lower in the GEM group at 1 month (P = 0.02), with no differences at other follow-up visits. Observer-reported scores did not differ significantly at any time point. Longitudinal analyses demonstrated no significant differences in patient- or observer-reported scar outcomes between groups (generalized estimating equation P = 0.69 and 0.67, respectively). GEM electrocautery was associated with lower measured blood loss and a shorter incision time (both P < 0.01).
Conclusions:: GEM electrocautery and conventional scalpel incisions achieved comparable long-term scar outcomes. Although GEM was associated with modest improvements in intraoperative parameters, the clinical significance of these differences should be interpreted in the context of the higher cost of the device.
Related
- Effects of serial casting on cardiac autonomic modulation in children with cerebral palsy: a single-blinded randomized controlled trial
- A placebo-controlled randomized cross-over lovastatin trial in neurofibromatosis type 1 reveals Ras/MAPK modulation of dynamic emotional face processing
- Electrocautery-Assisted Percutaneous Vacuum Aspiration of Dual Aortic Valve Fibroelastomas
- Short-term choroidal thickness modulation with SAT-001 digital software intervention in pediatric myopia: a randomized pilot study
- Topical trichloroacetic acid versus electrocautery for treatment of anal intraepithelial neoplasia in people living with HIV: a multicentre, randomised, non-inferiority trial (TECAIN-study)
BibTeX
@article{pojkhamkam2026scalpel,
title = {{Scalpel Versus Geometric Electron Modulation Electrocautery in Thyroid and Parathyroid Surgery: A Randomized Controlled Trial}},
author = {Tanatcha Pojkhamkam and Varut Supanakorn and Worawat Rawangban and Napadon Tangjaturonrasme and Wisarut Samuckkeethum},
journal = {Plastic and Reconstructive Surgery Global Open},
year = {2026},
month = nov,
doi = {10.1097/gox.0000000000008250},
url = {https://doi.org/10.1097/gox.0000000000008250},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Scalpel Versus Geometric Electron Modulation Electrocautery in Thyroid and Parathyroid Surgery: A Randomized Controlled Trial
AU - Tanatcha Pojkhamkam
AU - Varut Supanakorn
AU - Worawat Rawangban
AU - Napadon Tangjaturonrasme
AU - Wisarut Samuckkeethum
PY - 2026
DA - 2026/11/12
JO - Plastic and Reconstructive Surgery Global Open
DO - 10.1097/gox.0000000000008250
UR - https://doi.org/10.1097/gox.0000000000008250
AB - Background:: Postoperative scarring is an important concern following thyroid and parathyroid surgery. Geometric electron modulation (GEM) electrocautery is designed to reduce tissue injury while providing effective hemostasis. However, evidence regarding its long-term cosmetic outcomes remains limited. This study compares long-term scar quality following cervical incisions created using GEM electrocautery versus a conventional scalpel. Methods:: In this prospective, randomized, self-controlled trial, 24 patients undergoing thyroidectomy or parathyroidectomy were enrolled. Each half of the cervical incision was randomly assigned to GEM electrocautery or conventional scalpel. Intraoperative blood loss, incision time, and surgical field clarity were recorded. Scar quality was assessed at 2 weeks and at 1, 3, and 12 months using the Thai linear version of the Patient and Observer Scar Assessment Scale. Longitudinal analyses were performed using generalized estimating equations. Results:: Patient-reported Patient and Observer Scar Assessment Scale scores were significantly lower in the GEM group at 1 month (P = 0.02), with no differences at other follow-up visits. Observer-reported scores did not differ significantly at any time point. Longitudinal analyses demonstrated no significant differences in patient- or observer-reported scar outcomes between groups (generalized estimating equation P = 0.69 and 0.67, respectively). GEM electrocautery was associated with lower measured blood loss and a shorter incision time (both P < 0.01). Conclusions:: GEM electrocautery and conventional scalpel incisions achieved comparable long-term scar outcomes. Although GEM was associated with modest improvements in intraoperative parameters, the clinical significance of these differences should be interpreted in the context of the higher cost of the device.
SN - 2169-7574
ER -