Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 29 min ago
PreprintCC BY 4.0arXiv

Calibration of CMB Polarisation Using Cross-Experiment Correlations

Abstract

Parity-violating physics in the Universe can generate correlations between the Cosmic Microwave Background (CMB) E- and B-modes, but detecting such signals requires extremely accurate calibration of instruments. We describe a data-driven method to calibrate the relative polarisation angle between CMB experiments using cross-correlations of observations over a common sky region. Unlike standard self-calibration approaches, this method does not assume vanishing isotropic cosmic birefringence or primordial EB correlations when estimating the relative misalignment angle, and therefore preserves sensitivity to parity-violating physics. As a proof of concept, we forecast the performance of this method using the Simons Observatory (SO) Small Aperture Telescopes (SATs) as a calibrated reference. If they can be calibrated to an uncertainty of 0.08∘, as anticipated from the SO wire grid calibration system, we show that the SO Large Aperture Telescope and Planck could be calibrated to uncertainties of 0.10∘ and 0.17∘, respectively, at ∼ 145 GHz. This approach relies on the availability of at least one well-calibrated instrument, and provides a complementary path to improving polarisation calibration across experiments, enabling more robust searches for parity-violating physics in the CMB, such as cosmic birefringence.

Related

  1. A cross-calibration approach for polarisation-sensitive detectors in CMB experiments: application to LiteBIRD's polarisation angle calibration
    A. Novelli, F. Piacentini, S. Micheli +102
    arXivPreprintarXiv licenceFull textCosmologyInstrumentation & methodsarXiv
  2. Calibration electronics for the 30 and 40 GHz instrument (TFGI) of the QUIJOTE experiment
    Jorge Luis Díaz-Acosta, Roger John Hoyland, Francisco Javier Casas +1
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsApplied physics & instrumentationarXiv
  3. Flux Density Calibration of Radio Bursts Detected in the Sidelobes of the Canadian Hydrogen Intensity Mapping Experiment
    Fengqiu Adam Dong, Meena Seth, Paul Scholz +6
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsarXiv
  4. Cross-experiment tests of the atmospheric-muon excess
    G. I. Rubtsov, S. V. Troitsky
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsHigh-energy & particle physicsarXiv
  5. Optimal Statistic for a Stochastic Gravitational Wave Background using Pulsar-Timing--Astrometry Cross Correlations
    Kimberly K. Boddy, Jeffrey S. Hazboun, Kris Pardo
    arXivPreprintCC BY 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
BibTeX
@misc{rigouzzo2026calibration,
  title = {{Calibration of CMB Polarisation Using Cross-Experiment Correlations}},
  author = {Claire Rigouzzo and Eugene Lim and Susanna Azzoni and Yiqi Liu},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2606.11300},
  eprint = {2606.11300},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2606.11300},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Calibration of CMB Polarisation Using Cross-Experiment Correlations
AU  - Claire Rigouzzo
AU  - Eugene Lim
AU  - Susanna Azzoni
AU  - Yiqi Liu
PY  - 2026
DA  - 2026/11/10
PB  - arXiv
DO  - 10.48550/arxiv.2606.11300
UR  - https://arxiv.org/abs/2606.11300
AB  - Parity-violating physics in the Universe can generate correlations between the Cosmic Microwave Background (CMB) E- and B-modes, but detecting such signals requires extremely accurate calibration of instruments. We describe a data-driven method to calibrate the relative polarisation angle between CMB experiments using cross-correlations of observations over a common sky region. Unlike standard self-calibration approaches, this method does not assume vanishing isotropic cosmic birefringence or primordial EB correlations when estimating the relative misalignment angle, and therefore preserves sensitivity to parity-violating physics. As a proof of concept, we forecast the performance of this method using the Simons Observatory (SO) Small Aperture Telescopes (SATs) as a calibrated reference. If they can be calibrated to an uncertainty of 0.08^∘, as anticipated from the SO wire grid calibration system, we show that the SO Large Aperture Telescope and Planck could be calibrated to uncertainties of 0.10^∘ and 0.17^∘, respectively, at ∼ 145 GHz. This approach relies on the availability of at least one well-calibrated instrument, and provides a complementary path to improving polarisation calibration across experiments, enabling more robust searches for parity-violating physics in the CMB, such as cosmic birefringence.
ER  -