Functional Versus Mechanical Alignment in Robotic-Assisted Primary Total Knee Arthroplasty: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
11 affiliations
- 1Orthopaedics and Traumatology, Kulhudhuffushi Regional Hospital, Kulhudhuffushi, MDV
- 2Orthopaedics and Traumatology, Royal Devon University Healthcare NHS Foundation Trust, Barnstaple, GBR
- 3Orthopaedics and Traumatology, Central Clinic, Malé, MDV
- 4Orthopaedics and Traumatology, Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, BRN
- 5Orthopaedic and Traumatology, University of Medicine 1, Yangon, Yangon, MMR
- 6Orthopaedics and Traumatology, K. Himmafushi Health Centre, Himmafushi, MDV
- 7Orthopaedics and Traumatology, Yangon Orthopaedic Hospital, Yangon, MMR
- 8Orthopaedics and Traumatology, University of Medicine 1, Yangon, Yangon, MMR
- 9Emergency Department, Kulhudhuffushi Regional Hospital, Kulhudhuffushi, MDV
- 10Emergency Department, Nolhivaram Health Centre, Nolhivaram, MDV
- 11Orthopaedics and Traumatology, 200-Bedded Teaching Hospital, Magway, Magway, MMR
Abstract
Functional alignment (FA) in robotic-assisted total knee arthroplasty (TKA) aims to individualize component positioning and soft-tissue balance. However, whether these technical differences improve patient-reported outcomes compared with mechanical alignment (MA) remains uncertain.
A systematic review and meta-analysis of randomized controlled trials comparing FA and MA in primary robotic-assisted TKA was conducted. MEDLINE, Embase, and CENTRAL were searched, supplemented by trial registries and citation searching. The primary outcome was the Forgotten Joint Score (FJS) at approximately 12 months. Secondary outcomes included other patient-reported measures, soft-tissue release, radiological alignment, and complications. Risk of bias was assessed using RoB 2, and evidence certainty using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Random-effects meta-analysis was performed where appropriate, using restricted maximum likelihood estimation and Hartung-Knapp inference.
Of 406 database records, 11 reports representing seven independent randomized trial families were included. A definitive 12-month FJS meta-analysis was inappropriate because of methodological and reporting heterogeneity. Two randomized comparisons contributed to the early FJS analysis (≤six months). The pooled mean difference favoured FA by 8.62 points, but the Hartung-Knapp 95% confidence interval was wide (−16.90 to 34.14; I²=0%). A DerSimonian-Laird sensitivity analysis yielded a narrower interval (95% CI 4.56-12.68). FA was associated with fewer soft-tissue releases across several included trials. Radiological findings generally favoured preservation of individualized alignment, while patient-reported outcomes showed no consistent clinically important improvement. Serious complications and revisions were uncommon, and certainty of evidence for principal outcomes was very low.
Robotic FA reduces the requirement for soft-tissue release and produces distinct radiological alignment patterns compared with MA. However, current randomized evidence does not establish superior patient-reported outcomes. Early FJS findings remain uncertain because of the limited evidence base and imprecision. Larger randomized trials with standardized protocols and longer follow-up are required.
Related
- Functional alignment versus mechanical alignment in total knee arthroplasty: a meta-analysis of randomized controlled trials
- Aspirin-Based Thromboprophylaxis Versus Anticoagulant Regimens After Total Hip or Knee Arthroplasty: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
- Cemented Versus Cementless Fixation in Primary Total Knee Arthroplasty: A Systematic Review and Narrative Synthesis of Randomized Controlled Trials
- Functional and Radiological Results of the Subvastus Versus Medial Parapatellar Method in Total Knee Arthroplasty: A Randomized Controlled Cohort.
- Exercise-based rehabilitation interventions for kinesiophobia after total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials.
BibTeX
@article{zin2026functional,
title = {{Functional Versus Mechanical Alignment in Robotic-Assisted Primary Total Knee Arthroplasty: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials}},
author = {Nay Aung Zin and Sai Tun and Min Maung Maung and Phay Phone Paing and Phyo Thant and Htoo Aung Naing Shwe and Thi La Si Thu and Thu Ya Aung and Brang Jar and Phyu S Thwin and Paing Ye Kyaw and Than Htay},
journal = {Cureus},
year = {2026},
month = oct,
doi = {10.7759/cureus.118404},
url = {https://europepmc.org/article/PMC/PMC13788949},
note = {CC BY},
}
RIS
TY - JOUR
TI - Functional Versus Mechanical Alignment in Robotic-Assisted Primary Total Knee Arthroplasty: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
AU - Nay Aung Zin
AU - Sai Tun
AU - Min Maung Maung
AU - Phay Phone Paing
AU - Phyo Thant
AU - Htoo Aung Naing Shwe
AU - Thi La Si Thu
AU - Thu Ya Aung
AU - Brang Jar
AU - Phyu S Thwin
AU - Paing Ye Kyaw
AU - Than Htay
PY - 2026
DA - 2026/10/22
JO - Cureus
DO - 10.7759/cureus.118404
UR - https://europepmc.org/article/PMC/PMC13788949
AB - Functional alignment (FA) in robotic-assisted total knee arthroplasty (TKA) aims to individualize component positioning and soft-tissue balance. However, whether these technical differences improve patient-reported outcomes compared with mechanical alignment (MA) remains uncertain. A systematic review and meta-analysis of randomized controlled trials comparing FA and MA in primary robotic-assisted TKA was conducted. MEDLINE, Embase, and CENTRAL were searched, supplemented by trial registries and citation searching. The primary outcome was the Forgotten Joint Score (FJS) at approximately 12 months. Secondary outcomes included other patient-reported measures, soft-tissue release, radiological alignment, and complications. Risk of bias was assessed using RoB 2, and evidence certainty using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Random-effects meta-analysis was performed where appropriate, using restricted maximum likelihood estimation and Hartung-Knapp inference. Of 406 database records, 11 reports representing seven independent randomized trial families were included. A definitive 12-month FJS meta-analysis was inappropriate because of methodological and reporting heterogeneity. Two randomized comparisons contributed to the early FJS analysis (≤six months). The pooled mean difference favoured FA by 8.62 points, but the Hartung-Knapp 95% confidence interval was wide (−16.90 to 34.14; I²=0%). A DerSimonian-Laird sensitivity analysis yielded a narrower interval (95% CI 4.56-12.68). FA was associated with fewer soft-tissue releases across several included trials. Radiological findings generally favoured preservation of individualized alignment, while patient-reported outcomes showed no consistent clinically important improvement. Serious complications and revisions were uncommon, and certainty of evidence for principal outcomes was very low. Robotic FA reduces the requirement for soft-tissue release and produces distinct radiological alignment patterns compared with MA. However, current randomized evidence does not establish superior patient-reported outcomes. Early FJS findings remain uncertain because of the limited evidence base and imprecision. Larger randomized trials with standardized protocols and longer follow-up are required.
SN - 2168-8184
ER -