Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 36 min ago
Peer-reviewedCC BYInternational Journal of Cardiology: Heart & Vasculature

Segmental aortic energy loss in patients with bicuspid aortic valve

  1. 1Congenital Heart Disease and Pediatric Cardiology, German Heart Center, TUM University Hospital, School of Medicine and Health, Technical University of Munich, Munich, Germany

Abstract

Background: Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood. The primary objective was to compare total and segmental energy loss (EL) between patients with BAV without significant valve dysfunction and matched controls. The subsequent clinical and structural course of the BAV cohort was described. Methods: Sixteen patients with BAV and 16 matched controls underwent baseline four-dimensional flow cardiovascular magnetic resonance. Total and segmental aortic EL were quantified and normalized to flow. Commissural orientation was assessed. Clinical follow-up was available in all 16 patients with BAV, and paired baseline and approximately 10-year CMR assessments of aortic dimensions were available in 14. Results: Mean flow-normalized EL was approximately twofold higher in patients with BAV from the sinus of Valsalva to proximal ascending aorta (0.78 [0.59–1.14] vs 0.40 [0.29–0.67] mW/[L/min]; P = 0.015) and from proximal to distal ascending aorta (1.26 [0.79–1.59] vs 0.64 [0.39–1.07] mW/[L/min]; P = 0.013). Commissural angle was not significantly associated with segmental EL. No major BAV-related cardiovascular complications occurred during follow-up. In paired examinations, maximum ascending aortic diameter increased from 3.40 ± 0.67 to 3.75 ± 0.67 cm (P < 0.001), whereas the body surface area-indexed increase was attenuated (1.88 ± 0.29 to 1.97 ± 0.33 cm/m 2 ; P = 0.056). Conclusions: Segmental aortic EL was increased in patients with BAV despite the absence of significant valve dysfunction. The approximately 10-year follow-up provides descriptive clinical and structural characterization but does not establish a relationship between baseline EL and subsequent outcomes.

Related

  1. Real-time three-dimensional echocardiographic assessment of the association between aortic diameter and left ventricular mechanical dyssynchrony in patients with bicuspid aortic valve
    Huan Liu, Xueting Guo, Kunxuan Liu +7
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  2. Transcatheter aortic valve replacement in bicuspid versus tricuspid aortic valves among patients with mixed aortic valve disease
    Boren Tan, Qifeng Zhu, Qiong Liu +8
    BMC Cardiovascular DisordersPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  3. Association of left atrial strain and stiffness index with ascending aortic dilatation in patients with bicuspid aortic valve
    Huan Liu, Kunxuan Liu, Xueting Guo +6
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Cardiovascular medicineCrossref
  4. Incidence and prevalence of cerebral hemorrhage in patients with bicuspid aortic valve
    Ramzi Ibrahim, Karam Albdour, Hoang Nhat Pham +5
    International Journal of Cardiology Congenital Heart DiseasePeer-reviewedCC BY-NC-NDFull textCardiovascular medicineDOAJEurope PMCPMC
  5. Acute Severe Aortic Regurgitation Immediately After Cardiopulmonary Bypass Initiation in a Patient With a Bicuspid Aortic Valve
    Takumi Yamamoto, Keisuke Sumii
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{harada2026segmental,
  title = {{Segmental aortic energy loss in patients with bicuspid aortic valve}},
  author = {Mikiko Harada and Maria Skarlatoudi and Nerejda Shehu and Heiko Stern and Peter Ewert and Christian Meierhofer},
  journal = {International Journal of Cardiology: Heart \& Vasculature},
  year = {2026},
  month = nov,
  doi = {10.1016/j.ijcha.2026.102043},
  url = {https://doi.org/10.1016/j.ijcha.2026.102043},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Segmental aortic energy loss in patients with bicuspid aortic valve
AU  - Mikiko Harada
AU  - Maria Skarlatoudi
AU  - Nerejda Shehu
AU  - Heiko Stern
AU  - Peter Ewert
AU  - Christian Meierhofer
PY  - 2026
DA  - 2026/11/16
JO  - International Journal of Cardiology: Heart & Vasculature
DO  - 10.1016/j.ijcha.2026.102043
UR  - https://doi.org/10.1016/j.ijcha.2026.102043
AB  - Background: Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood. The primary objective was to compare total and segmental energy loss (EL) between patients with BAV without significant valve dysfunction and matched controls. The subsequent clinical and structural course of the BAV cohort was described. Methods: Sixteen patients with BAV and 16 matched controls underwent baseline four-dimensional flow cardiovascular magnetic resonance. Total and segmental aortic EL were quantified and normalized to flow. Commissural orientation was assessed. Clinical follow-up was available in all 16 patients with BAV, and paired baseline and approximately 10-year CMR assessments of aortic dimensions were available in 14. Results: Mean flow-normalized EL was approximately twofold higher in patients with BAV from the sinus of Valsalva to proximal ascending aorta (0.78 [0.59–1.14] vs 0.40 [0.29–0.67] mW/[L/min]; P = 0.015) and from proximal to distal ascending aorta (1.26 [0.79–1.59] vs 0.64 [0.39–1.07] mW/[L/min]; P = 0.013). Commissural angle was not significantly associated with segmental EL. No major BAV-related cardiovascular complications occurred during follow-up. In paired examinations, maximum ascending aortic diameter increased from 3.40 ± 0.67 to 3.75 ± 0.67 cm (P < 0.001), whereas the body surface area-indexed increase was attenuated (1.88 ± 0.29 to 1.97 ± 0.33 cm/m 2 ; P = 0.056). Conclusions: Segmental aortic EL was increased in patients with BAV despite the absence of significant valve dysfunction. The approximately 10-year follow-up provides descriptive clinical and structural characterization but does not establish a relationship between baseline EL and subsequent outcomes.
SN  - 2352-9067
ER  -