Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 51 min ago
Peer-reviewedCC BYRevista da Associacao Medica Brasileira (1992)

Evaluation of the ranawat triangle method for determining hip rotation center in total hip arthroplasty among Turkish patients

  1. 1Umraniye Training and Research Hospital, Department of Orthopaedics and Traumatology - Istanbul, Turkey.

Abstract

Objective

Accurate identification of the anatomical femoral head center is critical in total hip arthroplasty for optimal implant positioning and long-term survival. The Ranawat triangle method is widely used for this purpose, but its applicability may vary across populations. The aim of this study was to evaluate the accuracy and suitability of the Ranawat triangle method in estimating the anatomical femoral head center in a Turkish population.Methods

Standardized anteroposterior pelvic radiographs of 260 non-fractured hips from 312 patients aged 60-90 were retrospectively analyzed. Pelvic height, pelvic width, and femoral head diameter were measured. The coordinates of the anatomical femoral head center were calculated anatomically and using the Ranawat triangle method. Deviations between the two were assessed in both axes, with <5 mm considered acceptable error.Results

Anatomical femoral head center estimated by the Ranawat triangle method was positioned an average of 4.7±1.5 mm medially and 1.0±0.8 mm cranially in men, and 4.8±1.1 mm medially and 1.1±0.7 mm cranially in women, relative to the anatomical center. While 100% of Y-axis errors and 58.1% of X-axis errors were within 5 mm. Strong positive correlations were found between pelvic height and Cy (r=0.59), and pelvic width and Cx (r=0.82).Conclusion

The Ranawat triangle method method demonstrated excellent accuracy in predicting the vertical (Y-axis) position of the anatomical femoral head center but showed moderate lateral (X-axis) deviations in over 40% of cases. Despite its limitations in lateral offset prediction, it may serve as a practical reference method for preoperative planning, particularly for estimating the vertical position of the hip rotation center in Turkish total hip arthroplasty patients.

Related

  1. A smaller preoperative-to-prosthetic center of rotation shift is associated with better range of motion after bony increased-offset reverse shoulder arthroplasty: A retrospective cohort study of 97 patients by the FP-UCBM Shoulder Group
    Mauro Ciuffreda, Piergianni Luigi Di Santo, Antonino De Rosa +7
    Shoulder & ElbowPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosis
    T. A. Bouwmeester, D. Collard, I. A. J. Zijlstra +5
    medRxivPreprintCC BY-NC-NDFull textMedical imaging & radiologymedRxiv
  3. Construction and validation of a nomogram prediction model for the risk of delirium after hip arthroplasty in elderly patients
    Jiang He
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  4. Evaluating the safety of glucagon-like peptide-1 agonist use in non-diabetic overweight patients undergoing shoulder arthroplasty
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. The unintended consequences of outpatient total joint arthroplasty: a rising complication burden and decreasing reimbursement with the patients left behind.
    Seleem Elkadi, Matthew Salzler
    Annals of jointPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{dunki2026evaluation,
  title = {{Evaluation of the ranawat triangle method for determining hip rotation center in total hip arthroplasty among Turkish patients}},
  author = {Alper Dünki and Hakan Batuhan Kaya and Murat Birinci and Furkan Uçar and Ömer Polat and Savaş Çamur},
  journal = {Revista da Associacao Medica Brasileira (1992)},
  year = {2026},
  month = oct,
  doi = {10.1590/1806-9282.20260634},
  url = {https://europepmc.org/article/PMC/PMC13693300},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Evaluation of the ranawat triangle method for determining hip rotation center in total hip arthroplasty among Turkish patients
AU  - Alper Dünki
AU  - Hakan Batuhan Kaya
AU  - Murat Birinci
AU  - Furkan Uçar
AU  - Ömer Polat
AU  - Savaş Çamur
PY  - 2026
DA  - 2026/10/23
JO  - Revista da Associacao Medica Brasileira (1992)
DO  - 10.1590/1806-9282.20260634
UR  - https://europepmc.org/article/PMC/PMC13693300
AB  - Objective  Accurate identification of the anatomical femoral head center is critical in total hip arthroplasty for optimal implant positioning and long-term survival. The Ranawat triangle method is widely used for this purpose, but its applicability may vary across populations. The aim of this study was to evaluate the accuracy and suitability of the Ranawat triangle method in estimating the anatomical femoral head center in a Turkish population.Methods  Standardized anteroposterior pelvic radiographs of 260 non-fractured hips from 312 patients aged 60-90 were retrospectively analyzed. Pelvic height, pelvic width, and femoral head diameter were measured. The coordinates of the anatomical femoral head center were calculated anatomically and using the Ranawat triangle method. Deviations between the two were assessed in both axes, with <5 mm considered acceptable error.Results  Anatomical femoral head center estimated by the Ranawat triangle method was positioned an average of 4.7±1.5 mm medially and 1.0±0.8 mm cranially in men, and 4.8±1.1 mm medially and 1.1±0.7 mm cranially in women, relative to the anatomical center. While 100% of Y-axis errors and 58.1% of X-axis errors were within 5 mm. Strong positive correlations were found between pelvic height and Cy (r=0.59), and pelvic width and Cx (r=0.82).Conclusion  The Ranawat triangle method method demonstrated excellent accuracy in predicting the vertical (Y-axis) position of the anatomical femoral head center but showed moderate lateral (X-axis) deviations in over 40% of cases. Despite its limitations in lateral offset prediction, it may serve as a practical reference method for preoperative planning, particularly for estimating the vertical position of the hip rotation center in Turkish total hip arthroplasty patients.
SN  - 0104-4230
SN  - 1806-9282
ER  -