Skip to content
DraconiticResearch
Search Sources API
190,869 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY-NCJournal of chromatographic science

Glycopyrronium bromide, formoterol fumarate dihydrate and their related compounds with UPLC/PDA-MS for simultaneous determination in pressurized metered-dose inhaler product.

  1. 1Analytical Chemistry, Institute of Health Sciences, Istanbul University, 34126, Beyazıt, Istanbul, Türkiye.
  2. 2DEVA Holding A.S., R&D Center, Karaağaç Mh. Fatih Blv. No: 26, Kapaklı, 59510, Tekirdağ, Türkiye.
  3. 3Department of Analytical Chemistry, Faculty of Pharmacy, Istanbul University, Beyazıt, 34116, Istanbul, Türkiye.

Abstract

An ultra-performance liquid chromatography (UPLC) technique with photodiode array-mass spectrometry (PDA-MS) detectors has been developed and validated for the determination of glycopyrronium bromide (GB), formoterol fumarate dihydrate (FFD) and their related substances in pressurized meter dose inhalers. This marks the first time the method has been implemented. Chromatographic analyses have been carried out on a UPLC system with a single quadrupole mass spectrometer (QDa) and a PDA detector. A C18 column has been used prior to the injection valve. The column temperature was set to 40°C. For each analysis, 1 μL of sample was injected at a flow rate of 0.1 mL/minute. The mobile phases used were A (0.5% formic acid in methanol) and B (0.5% formic acid in water). The total run time of the method was 30 minutes. The PDA detector was employed at 215 nm while the mass detector was set to extracted ion chromatography (XIC) mode. The range for detecting impurities of GB was found to be between 0.28 and 0.30 ng/mL, with a limits of 0.92-1.01 ng/mL for quantification. GB and FFD demonstrated linear accuracy. We studied the accuracy of related substances within the limit of quantification value range of corresponding impurities and up to 400% of the limit value. The method we used was linear, rapid, reproducible and accurate. Our proposed method is fast, linear, accurate and reproducible. The UPLC-MS method, which utilized QDa with XIC mode, was developed to ascertain the related substances and assay of GB and FFD.

Related

  1. USP Standards for Dietary Ingredients Derived from Mate and Guayusa Leaves: A Quality by Design Approach to Method Development and Validation for the Simultaneous Determination of Methylxanthines and Hydroxycinnamoylquinic Acids
    Salika Jeelani, Greg Winter, Natalia Kouznetsova +1
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryCrossref
  2. Mechanistic Insights into Zinc Acetate Dihydrate–Catalyzed Depolymerization of Recycled PET for Polyol Production: A Combined Experimental and DFT Study
    Panachai Thusanaphoom, Nismar Parneam, Sineenard Songsri +6
    Journal of Molecular StructurePeer-reviewedCC BY 4.0Full textSystems & synthetic biologyGeneral chemistryHAL
  3. Adapting Pressurized Sample Infusion ESI-MS for Real-Time Monitoring of Heterogeneous Photoelectrocatalytic Reactions.
    Bobby A Ryane, Bragi Zhang, Maria E Muraro +3
    Journal of mass spectrometry : JMSPeer-reviewedCC BYFull textPhysical chemistryEurope PMCPMC
  4. From Field to Extract: Controlling Post-Harvest and Extraction Variables for Reproducible Recovery of Cannabinoids and Terpenes from Cannabis sativa L. by Sequential Hydrodistillation and Pressurized Liquid Extraction
    Carla Hamann, Olivia Jansen, Lucas Teilliez +6
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  5. Development of an LC–MS/MS Method for Simultaneous Quantification of Erythromycin A and Seven Metabolites: Initial Residue Profile in Salmon Muscle with Skin
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
BibTeX
@article{seckin2026glycopyrronium,
  title = {{Glycopyrronium bromide, formoterol fumarate dihydrate and their related compounds with UPLC/PDA-MS for simultaneous determination in pressurized metered-dose inhaler product.}},
  author = {Serdar Seckin and Serap Saglik Aslan},
  journal = {Journal of chromatographic science},
  year = {2026},
  month = oct,
  doi = {10.1093/chromsci/bmag030},
  url = {https://europepmc.org/article/MED/42893550},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Glycopyrronium bromide, formoterol fumarate dihydrate and their related compounds with UPLC/PDA-MS for simultaneous determination in pressurized metered-dose inhaler product.
AU  - Serdar Seckin
AU  - Serap Saglik Aslan
PY  - 2026
DA  - 2026/10/01
JO  - Journal of chromatographic science
DO  - 10.1093/chromsci/bmag030
UR  - https://europepmc.org/article/MED/42893550
AB  - An ultra-performance liquid chromatography (UPLC) technique with photodiode array-mass spectrometry (PDA-MS) detectors has been developed and validated for the determination of glycopyrronium bromide (GB), formoterol fumarate dihydrate (FFD) and their related substances in pressurized meter dose inhalers. This marks the first time the method has been implemented. Chromatographic analyses have been carried out on a UPLC system with a single quadrupole mass spectrometer (QDa) and a PDA detector. A C18 column has been used prior to the injection valve. The column temperature was set to 40°C. For each analysis, 1 μL of sample was injected at a flow rate of 0.1 mL/minute. The mobile phases used were A (0.5% formic acid in methanol) and B (0.5% formic acid in water). The total run time of the method was 30 minutes. The PDA detector was employed at 215 nm while the mass detector was set to extracted ion chromatography (XIC) mode. The range for detecting impurities of GB was found to be between 0.28 and 0.30 ng/mL, with a limits of 0.92-1.01 ng/mL for quantification. GB and FFD demonstrated linear accuracy. We studied the accuracy of related substances within the limit of quantification value range of corresponding impurities and up to 400% of the limit value. The method we used was linear, rapid, reproducible and accurate. Our proposed method is fast, linear, accurate and reproducible. The UPLC-MS method, which utilized QDa with XIC mode, was developed to ascertain the related substances and assay of GB and FFD.
SN  - 0021-9665
SN  - 1945-239X
ER  -