Skin safety during umbilical venous catheter insertion using 2% chlorhexidine gluconate in 70% isopropyl alcohol: a prospective observational study.
4 affiliations
- 1Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli n 8, 00168, Rome, Italy.
- 2Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli n 8, 00168, Rome, Italy. [email protected].
- 3Neonatal Intensive Care Unit, Infermi Hospital, Rimini, AUSL Romagna, Rimini, Italy.
- 4Neonatology Unit, Università Cattolica del Sacro Cuore, Rome, Italy.
Abstract
Background
Umbilical venous catheter (UVC) placement in NICU requires effective antisepsis to minimize catheter-related bloodstream infections. Chlorhexidine gluconate (CHG) in isopropyl alcohol (IPA) is commonly used, but its safety in preterm infants is debated. This study evaluates the skin safety of 2% CHG in 70% IPA during UVC placement in neonates.Methods
A prospective analysis of neonates admitted to a tertiary NICU from January 2021 to December 2024 was conducted. Skin reactions were assessed at 30 min, 24 h, and 48 h post-procedure. The primary outcome was the incidence of skin lesions categorized according to a dermatitis severity score.Results
Among 506 neonates, 48.4% had a gestational age ≤ 32 weeks. No severe lesions were observed. Erythema and discoloration were common but resolved within 48 h. The incidence of erythema decreased with increasing gestational age. Only two catheters were removed as a result of catheter-related bloodstream infections (0.89 per 1000 catheter days).Conclusions
2% CHG in 70% IPA showed a favorable safety profile in neonates undergoing UVC placement when appropriate precautions were observed.
Related
- Impact of chlorhexidine gluconate on periurethral cleansing on catheter-associated urinary tract infection: a before-and-after quasi-experimental study at a tertiary care hospital.
- Palatal miniscrew post-insertion pain: An observational prospective study on consecutively treated patients
- Protocol of a Real‐World Prospective Observational Study of Amivantamab Plus Chemotherapy in Patients With EGFR Exon 20 Insertion–Positive Non‐Small Cell Lung Cancer (SPIRAL‐RACER20 Study)
- Role of Amniotic Fluid to Umbilical Cerebral Ratio for Anticipation of Perinatal Outcome in Appropriate for Gestational Age Foetuses at Term: A Prospective Observational Study
- Association of placental weight and the umbilical coiling ındex with early neonatal adaptation in term neonates delivered by elective cesarean section under general anesthesia: a prospective observational study
BibTeX
@article{dandrea2026skin,
title = {{Skin safety during umbilical venous catheter insertion using 2% chlorhexidine gluconate in 70% isopropyl alcohol: a prospective observational study.}},
author = {Vito D'Andrea and Giorgia Prontera and Cecilia Monachini and Micaela Cerreti and Francesca Baldo and Giovanni Barone and Giovanni Vento},
journal = {Italian journal of pediatrics},
year = {2026},
month = aug,
doi = {10.1186/s13052-026-02326-2},
url = {https://europepmc.org/article/MED/43053188},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Skin safety during umbilical venous catheter insertion using 2% chlorhexidine gluconate in 70% isopropyl alcohol: a prospective observational study.
AU - Vito D'Andrea
AU - Giorgia Prontera
AU - Cecilia Monachini
AU - Micaela Cerreti
AU - Francesca Baldo
AU - Giovanni Barone
AU - Giovanni Vento
PY - 2026
DA - 2026/08/22
JO - Italian journal of pediatrics
DO - 10.1186/s13052-026-02326-2
UR - https://europepmc.org/article/MED/43053188
AB - Background Umbilical venous catheter (UVC) placement in NICU requires effective antisepsis to minimize catheter-related bloodstream infections. Chlorhexidine gluconate (CHG) in isopropyl alcohol (IPA) is commonly used, but its safety in preterm infants is debated. This study evaluates the skin safety of 2% CHG in 70% IPA during UVC placement in neonates.Methods A prospective analysis of neonates admitted to a tertiary NICU from January 2021 to December 2024 was conducted. Skin reactions were assessed at 30 min, 24 h, and 48 h post-procedure. The primary outcome was the incidence of skin lesions categorized according to a dermatitis severity score.Results Among 506 neonates, 48.4% had a gestational age ≤ 32 weeks. No severe lesions were observed. Erythema and discoloration were common but resolved within 48 h. The incidence of erythema decreased with increasing gestational age. Only two catheters were removed as a result of catheter-related bloodstream infections (0.89 per 1000 catheter days).Conclusions 2% CHG in 70% IPA showed a favorable safety profile in neonates undergoing UVC placement when appropriate precautions were observed.
SN - 1824-7288
ER -