Skip to content
DraconiticResearch
Search Sources API
182,460 studies31 sourcesUpdated 4 min ago
Peer-reviewedCC BYScientific Reports

Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations

  1. 1Scientific and Research Centre for Fire Protection, National Research Institute
  2. 2Institute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology
  3. 3Institute of Thermal Energy, Faculty of Environmental and Energy Engineering, Poznań University of Technology

Abstract

The effectiveness of mechanical tactical ventilation during rescue and firefighting operations can be improved by multiplying the number of positive pressure ventilators. Such action can shorten the time of the operation, improve its execution, and reduce the energy consumed by the ventilators used during the operation. In order to determine the proper conditions for the two ventilators to work together, tests were conducted on their positioning relative to the doorway. These values were determined from the flow parameters (flow rate and static overpressure generated). A set of conventional rotor ventilators (each with an output of 4.4 kW) was tested. The article performs an analysis of the magnitude of flow parameters depending on the setting of the positive pressure ventilator. Proper positioning of the set of ventilators can increase the flow rate through the facility by up to 32% and the pressure by 50%. The analysis conducted in the article can be used as recommendations for rescue teams for the proper selection of the setting of the positive pressure ventilator during firefighting operations of internal fires.

Related

  1. Effectiveness of personalized positioning management in preventing hypoxemia during sedated endoscopy: a retrospective study.
    Yuan Chen, Jia Zhu
    BMC gastroenterologyPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCDOAJ
  2. The Conventional Cost‐Effectiveness and Distributional Cost‐Effectiveness of Semaglutide for Obesity Treatment
    Neeti S. Kulkarni, David Hutton, Corwin Rhyan +3
    Obesity (Silver Spring, Md.)Peer-reviewedCC BY 4.0Full textGeneral medicinePMC
  3. Randomized Trial Assessing Oral Hygiene Effectiveness of Chewable Toothpaste Tablets versus Conventional Dentifrice in Undergraduate Dental Students
    Swayam Sourav Tripathy, Vikas Singh, Pradeep Tangade +4
    Journal of Indian Association of Public Health DentistryPeer-reviewedCC BY-NC-SAFull textGeneral medicineDOAJ
  4. Clinical Utility of Aerodynamic Measures in Vocal Fold Augmentation Outcomes
    Kelly Zdrowak, Ammar A. Rashied, Andrew Tkaczuk +2
    Journal of voice : official journal of the Voice FoundationPeer-reviewedLicence not statedFull textPhysiologyPMC
  5. New Insights into Avian Aerodynamic Valving: CT-Based CFD Analysis of Bronchial Airflow in the Domestic Chicken.
    Longhuan Du, Li Yang, Chenming Hu +10
    Animals : an open access journal from MDPIPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{kaczmarzyk2026aerodynamic,
  title = {{Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations}},
  author = {Piotr Kaczmarzyk and Rafał Noske and Damian Bąk and Piotr Krawiec and Bartosz Ziegler and Łukasz Warguła and Bartosz Wieczorek},
  journal = {Scientific Reports},
  year = {2026},
  month = jul,
  doi = {10.1038/s41598-026-62907-3},
  url = {https://doi.org/10.1038/s41598-026-62907-3},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations
AU  - Piotr Kaczmarzyk
AU  - Rafał Noske
AU  - Damian Bąk
AU  - Piotr Krawiec
AU  - Bartosz Ziegler
AU  - Łukasz Warguła
AU  - Bartosz Wieczorek
PY  - 2026
DA  - 2026/07/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-62907-3
UR  - https://doi.org/10.1038/s41598-026-62907-3
AB  - The effectiveness of mechanical tactical ventilation during rescue and firefighting operations can be improved by multiplying the number of positive pressure ventilators. Such action can shorten the time of the operation, improve its execution, and reduce the energy consumed by the ventilators used during the operation. In order to determine the proper conditions for the two ventilators to work together, tests were conducted on their positioning relative to the doorway. These values were determined from the flow parameters (flow rate and static overpressure generated). A set of conventional rotor ventilators (each with an output of 4.4 kW) was tested. The article performs an analysis of the magnitude of flow parameters depending on the setting of the positive pressure ventilator. Proper positioning of the set of ventilators can increase the flow rate through the facility by up to 32% and the pressure by 50%. The analysis conducted in the article can be used as recommendations for rescue teams for the proper selection of the setting of the positive pressure ventilator during firefighting operations of internal fires.
SN  - 2045-2322
ER  -