Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYCleaner Water

Explainable artificial intelligence for sustainable minimal-sensor monitoring of wastewater treatment performance: Reducing analytical burden using multi-year operational data

4 affiliations
  1. 1Department of Industrial Management, College of Business, Liwa University, Abu Dhabi, United Arab Emirates
  2. 2Laboratory of Water, Research, and Environmental Analysis, Faculty of Science, University of Abdelmalek Essaadi, B.P. 2121, M’Hannech II, Tétouan 93002, Morocco
  3. 3Laboratory of Biochemistry, Neuroscience, Natural Resources, and Environment (BNRNE), Faculty of Sciences and Techniques, Hassan First University of Settat, Settat, Morocco; Corresponding author.
  4. 4Laboratory of Biochemistry, Neuroscience, Natural Resources, and Environment (BNRNE), Faculty of Sciences and Techniques, Hassan First University of Settat, Settat, Morocco

Abstract

Laboratory monitoring demonstrates wastewater treatment performance, yet it consumes reagents, energy and analyst time and generates hazardous waste, and its cost often limits verification in resource-constrained settings. This study applies an explainable artificial intelligence (XAI) workflow to identify the minimal sensor subset able to verify treatment performance, using 124 paired influent/effluent days collected over two years at a full-scale activated-sludge plant serving 63 industries in Morocco. An availability audit showed that eight of the 17 declared parameters were never measured, leaving nine operated parameters (13 usable variables). Six regressors showed that chemical oxygen demand (COD) removal efficiency is predictable (coefficient of determination, R² = 0.747 ± 0.087), whereas effluent concentrations are not (R² ≤ 0.201). A consensus ranking combining SHapley Additive exPlanations (SHAP), permutation importance, recursive feature elimination and Boruta, confirmed by exhaustive search of 286 triples, selected effluent conductivity, influent COD and influent total suspended solids. This subset matched full-panel performance, outperformed it under chronological transfer (R² = 0.706 vs 0.531), and proved robust to imputation and undetected conductivity drift. It eliminates 15 of 18 daily determinations, reduces hazardous-reagent determinations by 83% in line with green analytical chemistry, and shortens time-to-result from 120 h to 3 h. A screening Monte Carlo scenario, modelled against a hypothetical baseline of daily full characterisation rather than measured facility expenditure, estimates reductions of about 79% in carbon dioxide-equivalent emissions and monitoring cost, and of 73% with quarterly recalibration. Probe-only monitoring failed, so the soft sensor still requires one influent laboratory measurement.

Related

  1. Artificial intelligence raises operational carbon emissions from data centers.
    Yajie Wang, Siqi Fang, Haibin Liu
    Environmental science and ecotechnologyPeer-reviewedCC BY-NC-NDFull textEnvironmental science & pollutionEurope PMCPMC
  2. Artificial Intelligence for Blue Transformation: A Review of Predictive Modeling and Decision Support Systems in Sustainable Aquaculture
    Mustafa Öz, Enes Üstüner
    Sustainable DevelopmentPeer-reviewedCC BY11 citedHydrology & soilsOpenAlex
  3. Artificial Intelligence (AI)‐Driven Precision Liming in Optimized Soil pH to Ensure Global Food Security and Sustainable Agriculture: A Systematic Review
    Simeneh Gedefaw Abate, Feng Liu
    The Scientific World JournalPeer-reviewedCC BY 4.0Full textHydrology & soilsPMC
  4. Explainable AI with dual-layer validation framework for ensuring noise resilience and physical consistency in low-cost sustainable water quality monitoring
    Wibowo Harry Sugiharto, Rizkysari Meimaharani, Ahmad Abdul Chamid +2
    Discover SustainabilityPeer-reviewedCC BYFull textHydrology & soilsDOAJ
  5. Sequential Fenton–ozonation treatment of textile wastewater: treatment performance and operational trade-offs
    Rawan Khatib, Muntjeer Ali, Juan F. Ortiz Medina +6
    Desalination and Water TreatmentPeer-reviewedCC BYFull textHydrology & soilsDOAJ
BibTeX
@article{lamii2026explainable,
  title = {{Explainable artificial intelligence for sustainable minimal-sensor monitoring of wastewater treatment performance: Reducing analytical burden using multi-year operational data}},
  author = {Nabil Lamii and Soufia Oumena and Dyaa Abou-tammame and Said Hattabi and Yahya Koulali},
  journal = {Cleaner Water},
  year = {2026},
  month = nov,
  doi = {10.1016/j.clwat.2026.100351},
  url = {https://doi.org/10.1016/j.clwat.2026.100351},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Explainable artificial intelligence for sustainable minimal-sensor monitoring of wastewater treatment performance: Reducing analytical burden using multi-year operational data
AU  - Nabil Lamii
AU  - Soufia Oumena
AU  - Dyaa Abou-tammame
AU  - Said Hattabi
AU  - Yahya Koulali
PY  - 2026
DA  - 2026/11/26
JO  - Cleaner Water
DO  - 10.1016/j.clwat.2026.100351
UR  - https://doi.org/10.1016/j.clwat.2026.100351
AB  - Laboratory monitoring demonstrates wastewater treatment performance, yet it consumes reagents, energy and analyst time and generates hazardous waste, and its cost often limits verification in resource-constrained settings. This study applies an explainable artificial intelligence (XAI) workflow to identify the minimal sensor subset able to verify treatment performance, using 124 paired influent/effluent days collected over two years at a full-scale activated-sludge plant serving 63 industries in Morocco. An availability audit showed that eight of the 17 declared parameters were never measured, leaving nine operated parameters (13 usable variables). Six regressors showed that chemical oxygen demand (COD) removal efficiency is predictable (coefficient of determination, R² = 0.747 ± 0.087), whereas effluent concentrations are not (R² ≤ 0.201). A consensus ranking combining SHapley Additive exPlanations (SHAP), permutation importance, recursive feature elimination and Boruta, confirmed by exhaustive search of 286 triples, selected effluent conductivity, influent COD and influent total suspended solids. This subset matched full-panel performance, outperformed it under chronological transfer (R² = 0.706 vs 0.531), and proved robust to imputation and undetected conductivity drift. It eliminates 15 of 18 daily determinations, reduces hazardous-reagent determinations by 83% in line with green analytical chemistry, and shortens time-to-result from 120 h to 3 h. A screening Monte Carlo scenario, modelled against a hypothetical baseline of daily full characterisation rather than measured facility expenditure, estimates reductions of about 79% in carbon dioxide-equivalent emissions and monitoring cost, and of 73% with quarterly recalibration. Probe-only monitoring failed, so the soft sensor still requires one influent laboratory measurement.
SN  - 2950-2632
ER  -