Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 17 min ago
Peer-reviewedCC BY-NC-NDBMC musculoskeletal disorders

Early clinical outcomes and learning curve study of robot-assisted precision osteotomy in total knee arthroplasty in the context of enhanced recovery after surgery.

4 affiliations
  1. 1Department of Orthopedic Surgery, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, 646000, China.
  2. 2Department of Orthopaedic Surgery, Panzhihua Central Hospital, Panzhihua, Sichuan, 617000, China.
  3. 3Chengdu University, Chengdu, Sichuan, 617000, China.
  4. 4Department of Orthopaedic Surgery, Panzhihua Central Hospital, Panzhihua, Sichuan, 617000, China. [email protected].

Abstract

Objective

To compare the early clinical outcomes of robot-assisted total knee arthroplasty (RA-TKA) with those of conventional manual total knee arthroplasty (CM-TKA) and analyse their learning curves.Methods

Patients who underwent initial unilateral total knee arthroplasty for osteoarthritis of the knee at Panzhihua Central Hospital between June and November 2023 were included in the study. A total of 130 patients were randomly divided into two groups: RA-TKA group underwent total knee arthroplasty with the HURWA Orthopaedic System (65 patients), and CM-TKA group patients underwent surgery with conventional tools (65 patients). Basic data, surgical information, imaging data and postoperative functional data were compared between the two groups. Surgical time was analysed via the cumulative sum analysis method (CUSUM), and the goodness of fit was assessed via R².Results

The baseline data were consistent between the two groups; moreover, the FFC of the patients in RA-TKA group was closer to 90° than that in CM-TKA group (89.1 ± 1.0° vs. 87.6 ± 1.9°, respectively; P < 0.001), the LTC was concentrated at 87° (86.8 ± 0.9° vs. 85.9 ± 2.3°, respectively; P = 0.006), and the HKA was concentrated at 180° (179.1 ± 1.0 vs. 176.7 ± 1.7, P < 0.001). There was no significant difference observed in inflammatory indicators or perioperative blood loss. Overall, 7.80% (RA-TKA group) and 9.52% (CM-TKA group) of the patients developed lower extremity intermuscular venous thrombosis, but there was no difference in knee function, pain or satisfaction. The operation time of RA-TKA group was approximately 11.3 min longer than that of CM-TKA group. The learning curve was best fitted as a cubic curve, and the fitted curve reached its apex when the number of surgical cases increased to 22. During the entire learning curve, no surgical termination or accidental injury caused by the failure of the robotic system occurred, and none of the patients suffered from serious complications such as infections, periprosthetic fracture, or cardiac and cerebral vascular accidents.Conclusion

HURWA robot-assisted TKA with learning curve fixation in approximately 22 patients achieved good lower limb force line reconstruction and precise implantation of the prosthesis, which is a safe and effective surgical procedure for treating osteoarthritis of the knee.Trial registration

The study was retrospectively registered on China Clinical Trials Registry (identifcation number: ChiCTR2400086729) on 07/09/2024. https://www.chictr.org.cn/bin/project/edit?pid=201488 .

Related

  1. Robot-assisted total hip arthroplasty: does improved precision translate into better clinical outcomes? A systematic review
    Ernesto Muñoz-Mahamud, Miquel Cortés-Rovira, Alfonso Alías-Petralanda +2
    International OrthopaedicsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Arthroplasty Outcomes After Robot-Assisted TKA: Does Radiographic Precision Translate Into Better Clinical Outcomes? A Systematic Review and Meta-analysis of Randomized Trials With ≥12-Month Follow-up
    Naif Bin Nwihadh Alshahrani, Mohammed M. Tarabishi, Majed Shaker Alasbali +9
    Orthopedic ReviewsPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaPMC
  3. Piezoelectric Versus Conventional Osteotomy Instruments in Bimaxillary Orthognathic Surgery: A Narrative Review of Surgical Efficiency, Safety, and Clinical Outcomes
    Renato Isufi, Aurora Isufi, Ramazan Isufi +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  4. Comparing Short-Term Clinical Outcomes and Survivorship of Complex Revision Total Hip Arthroplasty: Custom Triflange Acetabular Implants Vs Standard Cage Reconstruction
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. Early Revision Rates and Clinical Outcomes of Two Cementless Cruciate-Retaining Total Knee Arthroplasty Designs at Two-Year Follow-Up: A Propensity Score-Adjusted Comparative Analysis
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{wang2026early,
  title = {{Early clinical outcomes and learning curve study of robot-assisted precision osteotomy in total knee arthroplasty in the context of enhanced recovery after surgery.}},
  author = {Mingyou Wang and Hongping Wang and Zhuodong Tang and Qifeng Tao and Mingli Wang and Ruiqi Lan and Chunyu Chen and Yuping Lan},
  journal = {BMC musculoskeletal disorders},
  year = {2026},
  month = sep,
  doi = {10.1186/s12891-026-09864-0},
  url = {https://europepmc.org/article/MED/43009893},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Early clinical outcomes and learning curve study of robot-assisted precision osteotomy in total knee arthroplasty in the context of enhanced recovery after surgery.
AU  - Mingyou Wang
AU  - Hongping Wang
AU  - Zhuodong Tang
AU  - Qifeng Tao
AU  - Mingli Wang
AU  - Ruiqi Lan
AU  - Chunyu Chen
AU  - Yuping Lan
PY  - 2026
DA  - 2026/09/01
JO  - BMC musculoskeletal disorders
DO  - 10.1186/s12891-026-09864-0
UR  - https://europepmc.org/article/MED/43009893
AB  - Objective  To compare the early clinical outcomes of robot-assisted total knee arthroplasty (RA-TKA) with those of conventional manual total knee arthroplasty (CM-TKA) and analyse their learning curves.Methods  Patients who underwent initial unilateral total knee arthroplasty for osteoarthritis of the knee at Panzhihua Central Hospital between June and November 2023 were included in the study. A total of 130 patients were randomly divided into two groups: RA-TKA group underwent total knee arthroplasty with the HURWA Orthopaedic System (65 patients), and CM-TKA group patients underwent surgery with conventional tools (65 patients). Basic data, surgical information, imaging data and postoperative functional data were compared between the two groups. Surgical time was analysed via the cumulative sum analysis method (CUSUM), and the goodness of fit was assessed via R².Results  The baseline data were consistent between the two groups; moreover, the FFC of the patients in RA-TKA group was closer to 90° than that in CM-TKA group (89.1 ± 1.0° vs. 87.6 ± 1.9°, respectively; P < 0.001), the LTC was concentrated at 87° (86.8 ± 0.9° vs. 85.9 ± 2.3°, respectively; P = 0.006), and the HKA was concentrated at 180° (179.1 ± 1.0 vs. 176.7 ± 1.7, P < 0.001). There was no significant difference observed in inflammatory indicators or perioperative blood loss. Overall, 7.80% (RA-TKA group) and 9.52% (CM-TKA group) of the patients developed lower extremity intermuscular venous thrombosis, but there was no difference in knee function, pain or satisfaction. The operation time of RA-TKA group was approximately 11.3 min longer than that of CM-TKA group. The learning curve was best fitted as a cubic curve, and the fitted curve reached its apex when the number of surgical cases increased to 22. During the entire learning curve, no surgical termination or accidental injury caused by the failure of the robotic system occurred, and none of the patients suffered from serious complications such as infections, periprosthetic fracture, or cardiac and cerebral vascular accidents.Conclusion  HURWA robot-assisted TKA with learning curve fixation in approximately 22 patients achieved good lower limb force line reconstruction and precise implantation of the prosthesis, which is a safe and effective surgical procedure for treating osteoarthritis of the knee.Trial registration  The study was retrospectively registered on China Clinical Trials Registry (identifcation number: ChiCTR2400086729) on 07/09/2024. https://www.chictr.org.cn/bin/project/edit?pid=201488 .
SN  - 1471-2474
ER  -