Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 55 min ago
PreprintarXiv licencearXiv

Experimental verification of the PRIORA Monte Carlo code for proton radiography

Abstract

PRIORA (Proton Radiography Ion-Optical Ray-tracing Analysis) is a fast Monte Carlo model for high-energy proton radiography. It combines fitted proton-matter interaction tables with energy-dependent transfer maps of arbitrary order and simulates approximately 106 protons/s through a complete ion-optical system on an 8-core laptop. We verify it with GSI data obtained with the Ta_bench target: fifteen precision slits in a 2 mm Ta plate between symmetric PMMA staircases. A single experimental image provides the image scale, spatial resolution as a function of chromatic load, the direction of longitudinal defocus in both transverse planes, effective angular acceptance and multiple-scattering contrast. With identical processing of experiment and simulation and no physics adjustment, PRIORA reproduces the data obtained with 2 and 4 GeV protons. At 2 GeV, PRIORA also recovers sub-percent quadrupole trims consistent with the control-system records and determines a target-plane spatial resolution of 115±6 μm.

Related

  1. Measuring electron density and electromagnetic fields in low-density laser-driven plasmas using proton radiography
    Joshua T. Y. Chu, Gianluca Gregori, Petros Tzeferacos +1
    arXivPreprintCC BY 4.0Full textPlasma physicsarXiv
  2. Dynamic calibration method for the system constant of high-spectral-resolution lidar with airborne experimental verification
    Li Ping, Fanqian Meng, Juxin yang +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. The efficiency of moderating neutron detector: Monte Carlo simulation, experimental validation, and angular dependence
    Carl R. Brune
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationNuclear physicsarXiv
  4. Experimental Verification of Circumferential Bunch Length Variation and Head-Tail Exchange Affecting Microwave Instability in a Storage Ring
    Jihong Bian, Xiujie Deng, Arne Hoehl +5
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  5. Experimental and simulated H2O2 in pure water under conventional and ultra-high dose rates for single pulse proton irradiation
    Daeun Kwon, Vincent Fiegel, Guillaume Blain +11
    Medical Physics : The international journal of medical physics research and practicePeer-reviewedCC BY 4.0Full textGeneral chemistryBiological & medical physicsHAL
BibTeX
@misc{varentsov2026experimental,
  title = {{Experimental verification of the PRIORA Monte Carlo code for proton radiography}},
  author = {Dmitry Varentsov and Martin Schanz and John Schmidt},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.26121},
  eprint = {2610.26121},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.26121},
}
RIS
TY  - UNPB
TI  - Experimental verification of the PRIORA Monte Carlo code for proton radiography
AU  - Dmitry Varentsov
AU  - Martin Schanz
AU  - John Schmidt
PY  - 2026
DA  - 2026/10/27
PB  - arXiv
DO  - 10.48550/arxiv.2610.26121
UR  - https://arxiv.org/abs/2610.26121
AB  - PRIORA (Proton Radiography Ion-Optical Ray-tracing Analysis) is a fast Monte Carlo model for high-energy proton radiography. It combines fitted proton-matter interaction tables with energy-dependent transfer maps of arbitrary order and simulates approximately 10^6 protons/s through a complete ion-optical system on an 8-core laptop. We verify it with GSI data obtained with the Ta_bench target: fifteen precision slits in a 2 mm Ta plate between symmetric PMMA staircases. A single experimental image provides the image scale, spatial resolution as a function of chromatic load, the direction of longitudinal defocus in both transverse planes, effective angular acceptance and multiple-scattering contrast. With identical processing of experiment and simulation and no physics adjustment, PRIORA reproduces the data obtained with 2 and 4 GeV protons. At 2 GeV, PRIORA also recovers sub-percent quadrupole trims consistent with the control-system records and determines a target-plane spatial resolution of 115±6 μm.
ER  -