Comparison of visual estimation of ventricular systolic function with quantitative echocardiographic markers in newborn infants.

4 affiliations
  1. 1Neonatal Unit, Homerton University Hospital, Homerton Healthcare NHS Foundation Trust, London, UK. [email protected].
  2. 2Centre for Genomics and Child Health, Barts and the London School of Medicine and Dentistry, London, UK. [email protected].
  3. 3Neonatal Unit, Homerton University Hospital, Homerton Healthcare NHS Foundation Trust, London, UK.
  4. 4Neonatal Unit, Aberdeen Maternity Hospital, NHS Grampian, Aberdeen, UK.

Abstract

Background

Neonatologist-performed echocardiography (NPE) is increasingly practiced. NPE operators typically use visual estimation of systolic function and, if indicated, confirm function using quantitative echocardiographic markers. This exploratory study aims to compare the concordance between qualitative and quantitative echocardiographic markers among NPE and non-NPE operators.Methods

We studied a cohort of newborn infants, undergoing routine NPE by the authors at Homerton University Hospital and Aberdeen Maternity Hospital from April 2024 to October 2024. Blinded NPE and non-NPE operators independently assessed left and right ventricular systolic function visually. We compared visual estimation with standard quantitative echocardiographic markers such as shortening fraction, Simpson's ejection fraction and global longitudinal strain for left ventricle and tricuspid annular plane systolic excursion and fractional area change for right ventricle. We examined the concordance between visual estimation and quantitative echocardiographic markers for biventricular systolic function.Results

Sixty infants with a mean (SD) gestation and birth weight of 34 (6.2) weeks and 2311 (1319) grams respectively were examined. Sensitivity testing for all echocardiographic parameters ranged from 25% to 80% whereas specificity ranged from 38% to 78%. Sensitivity increased with worsening grades of LV dysfunction defined using shortening fraction. While concordance between NPE and non-NPE operator was generally limited across most echocardiographic parameters, test-retest reliability was acceptable for several quantitative measures, including Simpson's ejection fraction, global longitudinal strain and right ventricular fractional area change.Conclusion

Visual estimation may be a useful bedside tool for detecting severe ventricular dysfunction in newborn infants; however; quantitative echocardiographic measures are likely to improve the assessment of mild to moderate dysfunction. Further studies should confirm these findings in a larger cohort with a higher representation of infants with ventricular dysfunction.

Related

  1. Graves’ Disease and the Heart: Severe Reversible Left Ventricular Systolic Dysfunction With Apical Thrombus in a Young Woman With Relapsed Thyrotoxicosis
    Jomol Joseph, Chandranath Sarkar, Sai Aditya Boda
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Nebivolol for the Prevention of Left Ventricular Systolic Dysfunction in Patients With Duchenne Muscular Dystrophy: the NEBIDYS trial
    Luca Monzo, Henri-Marc Becane, Yves Dulac +14
    European Heart Journal - Cardiovascular PharmacotherapyPeer-reviewedCC BY 4.0Full textCardiovascular medicineHAL
  3. Development and Population-Based Prognostic Utility Assessment of an ICD-10-CM-Based Prediction Model to Identify Left Ventricular Systolic Dysfunction: Discrimination Performance and Population-Based Evaluation in 83,357 Patients with Acute Coronary Syndrome
    Andreea Eunice Cosa, Marc Llagostera Martin, Sílvia Jovells-Vaqué +13
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Novel Large Language Model-Based Detection of Echocardiographic Markers of Right Ventricular Dysfunction
    L. Ekambarapu, A. Pendyal, A. Lin +2
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  5. Echocardiographic assessment of left ventricular mass in children with severe malaria at two tertiary institutions in Southeast Nigeria
    Josephat M. Chinawa, Ngozi R. Mbanefo, Bartholomew F. Chukwu
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicineCrossref
BibTeX
@article{pereira2026comparison,
  title = {{Comparison of visual estimation of ventricular systolic function with quantitative echocardiographic markers in newborn infants.}},
  author = {Sujith S Pereira and Beena Yeldo and Rachael Fleming and Saulius Satas},
  journal = {Echo research and practice},
  year = {2026},
  month = oct,
  doi = {10.1186/s44156-026-00142-2},
  url = {https://europepmc.org/article/MED/42928354},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparison of visual estimation of ventricular systolic function with quantitative echocardiographic markers in newborn infants.
AU  - Sujith S Pereira
AU  - Beena Yeldo
AU  - Rachael Fleming
AU  - Saulius Satas
PY  - 2026
DA  - 2026/10/26
JO  - Echo research and practice
DO  - 10.1186/s44156-026-00142-2
UR  - https://europepmc.org/article/MED/42928354
AB  - Background  Neonatologist-performed echocardiography (NPE) is increasingly practiced. NPE operators typically use visual estimation of systolic function and, if indicated, confirm function using quantitative echocardiographic markers. This exploratory study aims to compare the concordance between qualitative and quantitative echocardiographic markers among NPE and non-NPE operators.Methods  We studied a cohort of newborn infants, undergoing routine NPE by the authors at Homerton University Hospital and Aberdeen Maternity Hospital from April 2024 to October 2024. Blinded NPE and non-NPE operators independently assessed left and right ventricular systolic function visually. We compared visual estimation with standard quantitative echocardiographic markers such as shortening fraction, Simpson's ejection fraction and global longitudinal strain for left ventricle and tricuspid annular plane systolic excursion and fractional area change for right ventricle. We examined the concordance between visual estimation and quantitative echocardiographic markers for biventricular systolic function.Results  Sixty infants with a mean (SD) gestation and birth weight of 34 (6.2) weeks and 2311 (1319) grams respectively were examined. Sensitivity testing for all echocardiographic parameters ranged from 25% to 80% whereas specificity ranged from 38% to 78%. Sensitivity increased with worsening grades of LV dysfunction defined using shortening fraction. While concordance between NPE and non-NPE operator was generally limited across most echocardiographic parameters, test-retest reliability was acceptable for several quantitative measures, including Simpson's ejection fraction, global longitudinal strain and right ventricular fractional area change.Conclusion  Visual estimation may be a useful bedside tool for detecting severe ventricular dysfunction in newborn infants; however; quantitative echocardiographic measures are likely to improve the assessment of mild to moderate dysfunction. Further studies should confirm these findings in a larger cohort with a higher representation of infants with ventricular dysfunction.
SN  - 2055-0464
ER  -