Skip to content
DraconiticResearch
Search Sources API
186,625 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BY 4.0PLOS One

Construction of an experimental set up to perform full body micro cannulations of sub-millimetric vessels in an anatomical research setting

7 affiliations
  1. 1Department of Human Structure and Repair, Ghent University, Ghent, Belgium
  2. 2Cancer Research Institute Ghent (CRIG), Ghent University, Ghent, Belgium
  3. 3Evolutionairy Morphology of Vertebrates, Ghent University, Ghent, Belgium
  4. 4IBiTech-bioMMeda, Ghent University, Ghent, Belgium
  5. 5Department of Plastic Surgery, Ghent University Hospital, Ghent, Belgium
  6. 6Breast Clinic, Ghent University Hospital, Ghent, Belgium
  7. 7Department of Oral Health Sciences, Ghent University, Ghent, Belgium

Abstract

Introduction: A better 3D visualisation of the lymphatic system could provide more accurate cancer treatment approaches, but this requires contrast agent injections. Since lymphatic vessels are very small, cannulations to administer contrast agent are very difficult to perform manually. As such, a dedicated set up for lymphatic vessel micro cannulations is required. Materials and methods: A micromanipulator rig for full body micro cannulations was constructed. The rig consists of an aluminium frame that can be positioned over a dissection table. It combines the micromanipulator with a sliding gantry plate and a double jointed positioning system to provide as many possible angles of approach as possible. Fluid pressure control devices and a surgical microscope can also be included in the set up. Results: Micro cannulations on a full body could successfully be performed using the micromanipulator rig. After only a short learning curve to explore the movement possibilities/range of the device, the micromanipulator rig quickly outperformed manual micro cannulations. Conclusions: Given the short learning curve and the success rate of the micro cannulations with the micromanipulator rig, we would strongly recommend other microvascular researchers to use the micromanipulator rig for future experiments involving micro cannulations.

Related

  1. Construction and validation of a three-dimensional CT spatial localization algorithm for segond fracture based on tibial bony landmarks: an anatomical reference study for AI-assisted preoperative planning.
    Ziteng Guo, Chenggang Yang, Yongchen Zheng +6
    Frontiers in medicinePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  2. Anatomical and Technical Limitations of a Rabbit Median Sternotomy Model for Translational Mediastinal Adhesion Research
    Doğuş Hemşinli, Sedat Ozan Karakişi, Atilla Topçu +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Aortic and innominate cannulations are equally safe in redo aortic surgery.
    Bo Chang Brian Wu, Meng-Han Tsai, Drake S Rosenberg +4
    JTCVS openPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCPMC
  4. Research on the student-centered research feedback experimental teaching model to enhance the effectiveness of pharmacology experimental teaching.
    Chenggui Miao, Jiaqing Chen, Yanping Li +5
    MedicinePeer-reviewedCC BY-NCFull textEpidemiology & public healthEurope PMC
  5. Large language model consensus for reliable research cohort construction from radiology reports: a retrospective cohort study
    W. Rui, J. Ma, V. Stepanov +7
    medRxivPreprintCC BY-NC-NDFull textMedical imaging & radiologymedRxiv
BibTeX
@article{stouthandel2026construction,
  title = {{Construction of an experimental set up to perform full body micro cannulations of sub-millimetric vessels in an anatomical research setting}},
  author = {Michael E. J. Stouthandel and Danial Forouhar and Charlotte Debbaut and Jurgen Deviche and Liesl De Graeve and Bernard Depypere and Maarten Meire and Dominique Adriaens and Tom Van Hoof},
  journal = {PLOS One},
  year = {2026},
  month = sep,
  doi = {10.1371/journal.pone.0358264},
  url = {https://doi.org/10.1371/journal.pone.0358264},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Construction of an experimental set up to perform full body micro cannulations of sub-millimetric vessels in an anatomical research setting
AU  - Michael E. J. Stouthandel
AU  - Danial Forouhar
AU  - Charlotte Debbaut
AU  - Jurgen Deviche
AU  - Liesl De Graeve
AU  - Bernard Depypere
AU  - Maarten Meire
AU  - Dominique Adriaens
AU  - Tom Van Hoof
PY  - 2026
DA  - 2026/09/11
JO  - PLOS One
DO  - 10.1371/journal.pone.0358264
UR  - https://doi.org/10.1371/journal.pone.0358264
AB  - Introduction: A better 3D visualisation of the lymphatic system could provide more accurate cancer treatment approaches, but this requires contrast agent injections. Since lymphatic vessels are very small, cannulations to administer contrast agent are very difficult to perform manually. As such, a dedicated set up for lymphatic vessel micro cannulations is required. Materials and methods: A micromanipulator rig for full body micro cannulations was constructed. The rig consists of an aluminium frame that can be positioned over a dissection table. It combines the micromanipulator with a sliding gantry plate and a double jointed positioning system to provide as many possible angles of approach as possible. Fluid pressure control devices and a surgical microscope can also be included in the set up. Results: Micro cannulations on a full body could successfully be performed using the micromanipulator rig. After only a short learning curve to explore the movement possibilities/range of the device, the micromanipulator rig quickly outperformed manual micro cannulations. Conclusions: Given the short learning curve and the success rate of the micro cannulations with the micromanipulator rig, we would strongly recommend other microvascular researchers to use the micromanipulator rig for future experiments involving micro cannulations.
SN  - 1932-6203
ER  -