Improved Threshold for Particle-Induced Magnetic Avalanche in Single-Molecule Magnets Using Fe8 Molecule
Abstract
Extending the original work on the development of a magnetic avalanche detector using Mn12-ac single-molecule magnet (SMM), we report the results on a significantly lower threshold magnetic avalanche detector using Fe8 SMM. Fe8 has an order of magnitude smaller relaxation time that is expected to produce at least 3 orders of magnitude lower avalanche threshold compared to Mn12-ac. We confirm this experimentally through the detection of gamma particles with energy at least two orders of magnitude lower than the original Mn12-ac detection demonstrated using alpha particles, limited by the experimentally available radiation source. The true threshold of avalanche may be significantly lower and will be explored with lower energy x-rays and potentially infrared photons.
Related
- Implementation and verification of the avalanche source in a 3D full-f particle-in-cell model of relativistic electrons for studies of tokamak disruptions
- An improved partial-wave projection of the one-particle exchange in relativistic three-body scattering
- Improved mean squared displacement analysis for anomalous single particle trajectories
- Anisometric Dielectric Snowman-Particle Provides Improved Control Over Photonic Hook
- An improved self-gravity treatment in general relativistic smoothed particle hydrodynamics
BibTeX
@misc{kohn2026improved,
title = {{Improved Threshold for Particle-Induced Magnetic Avalanche in Single-Molecule Magnets Using Fe$_8$ Molecule}},
author = {Bailey Kohn and Rupak Mahapatra and Ivan Borzenets and Lok Raj Pant and Amis Sharma and Tom Melia and Michael Nippe and Anna Schmautz and Surjeet Rajendran},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.00360},
eprint = {2609.00360},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.00360},
}
RIS
TY - UNPB
TI - Improved Threshold for Particle-Induced Magnetic Avalanche in Single-Molecule Magnets Using Fe_8 Molecule
AU - Bailey Kohn
AU - Rupak Mahapatra
AU - Ivan Borzenets
AU - Lok Raj Pant
AU - Amis Sharma
AU - Tom Melia
AU - Michael Nippe
AU - Anna Schmautz
AU - Surjeet Rajendran
PY - 2026
DA - 2026/09/01
PB - arXiv
DO - 10.48550/arxiv.2609.00360
UR - https://arxiv.org/abs/2609.00360
AB - Extending the original work on the development of a magnetic avalanche detector using Mn_12-ac single-molecule magnet (SMM), we report the results on a significantly lower threshold magnetic avalanche detector using Fe_8 SMM. Fe_8 has an order of magnitude smaller relaxation time that is expected to produce at least 3 orders of magnitude lower avalanche threshold compared to Mn_12-ac. We confirm this experimentally through the detection of gamma particles with energy at least two orders of magnitude lower than the original Mn_12-ac detection demonstrated using alpha particles, limited by the experimentally available radiation source. The true threshold of avalanche may be significantly lower and will be explored with lower energy x-rays and potentially infrared photons.