A Two-Stage Parallel Inception 1D-CNN for Event-Driven Condition Monitoring
- 1Faculty of Mechanical Engineering and Informatics, University of Miskolc, 3515 Miskolc, Hungary
Abstract
Digital twins (DTs) of collaborative robots need continuous synchronization, but streaming high-rate kinematic telemetry to a central DT can create bandwidth bottlenecks. Protocol overhead exceeds 70% of the packet volume for raw sensor data in a projected 1000Hz scenario. This work proposes an Edge-Enabled Digital Twin Networked Control System (E-DTNCS) in which an edge node classifies IMU data windows and sends a low-rate heartbeat in normal operation and a raw-data burst when an anomaly is detected. A compact two-stage Parallel Inception 1D-CNN (PINC-noBN, 37,154 parameters) is evaluated as a classifier on the public CASPER dataset (20Hz UR3e IMU data) with a chronological split and three seeds. With the given labels, it reaches a test accuracy of 0.86±0.02, slightly below a CASPER-style 1D-CNN with kernel size 50 (0.88±0.01, 169,794 parameters). Errors concentrate near class transitions, where labels are offset from the signal by several minutes; excluding these zones, accuracies are 0.97 and 0.99. An analytical projection including false-positive bursts indicates bandwidth reductions of 85–92% (labels as given) and 90–99.8% (transition zones excluded) for anomaly prevalences between 10% and 0.1%. In float32, PINC-noBN needs at least 2 MB of activation memory.
Related
- Fixed-ground multisensor monitoring resolves longitudinal vegetation condition and fuel-state structure in Southern California chaparral and oak scenes
- Flexible cognition, perceived conflict, and self-monitoring in autism spectrum condition
- Life stage shapes condition-dependent foraging under predation risk in an electric fish
- Microeukaryotic indicators of freshwater ecosystem condition from a national river monitoring network
- Automated Identification of Parasitoid Wasps for Biological Control Monitoring Using an Optimized Single-Stage Detector
BibTeX
@article{bodnar2026twostage,
title = {{A Two-Stage Parallel Inception 1D-CNN for Event-Driven Condition Monitoring}},
author = {Dávid Bodnár and Károly Jármai},
journal = {Applied Sciences},
year = {2026},
month = nov,
doi = {10.3390/app162110963},
url = {https://doi.org/10.3390/app162110963},
note = {CC BY},
}
RIS
TY - JOUR
TI - A Two-Stage Parallel Inception 1D-CNN for Event-Driven Condition Monitoring
AU - Dávid Bodnár
AU - Károly Jármai
PY - 2026
DA - 2026/11/13
JO - Applied Sciences
DO - 10.3390/app162110963
UR - https://doi.org/10.3390/app162110963
AB - Digital twins (DTs) of collaborative robots need continuous synchronization, but streaming high-rate kinematic telemetry to a central DT can create bandwidth bottlenecks. Protocol overhead exceeds 70% of the packet volume for raw sensor data in a projected 1000Hz scenario. This work proposes an Edge-Enabled Digital Twin Networked Control System (E-DTNCS) in which an edge node classifies IMU data windows and sends a low-rate heartbeat in normal operation and a raw-data burst when an anomaly is detected. A compact two-stage Parallel Inception 1D-CNN (PINC-noBN, 37,154 parameters) is evaluated as a classifier on the public CASPER dataset (20Hz UR3e IMU data) with a chronological split and three seeds. With the given labels, it reaches a test accuracy of 0.86±0.02, slightly below a CASPER-style 1D-CNN with kernel size 50 (0.88±0.01, 169,794 parameters). Errors concentrate near class transitions, where labels are offset from the signal by several minutes; excluding these zones, accuracies are 0.97 and 0.99. An analytical projection including false-positive bursts indicates bandwidth reductions of 85–92% (labels as given) and 90–99.8% (transition zones excluded) for anomaly prevalences between 10% and 0.1%. In float32, PINC-noBN needs at least 2 MB of activation memory.
SN - 2076-3417
ER -