Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BY-NC-SAJournal of anaesthesiology, clinical pharmacology

Comparative analysis of comfort of noninvasive ventilation (NIV) with a conventional oronasal mask and a bridge-free oronasal mask: A randomized controlled trial.

  1. 1Department of Anesthesiology and Critical Care, All India Institute of Medical Science, Jodhpur, Rajasthan, India.

Abstract

Background and aims

Non-invasive ventilation (NIV) effectiveness depends largely on ventilator settings and interface design. Conventional oronasal masks often exert pressure on the nasal bridge, causing discomfort, skin injury, and poor tolerance, which may lead to NIV failure. Bridge-free oronasal masks eliminate nasal bridge contact and may enhance comfort and overall compliance. This study compared patient comfort, ventilatory performance, and mask-related complications between bridge-free and conventional oronasal masks during NIV.Material and methods

A prospective randomized unblinded controlled crossover trial involving 84 adult patients requiring NIV. Participants were divided into two groups: Group AB received the bridge-free mask for 2 hours followed by a conventional mask for 2 hours, while Group BA received them in reverse order. Data collected included comfort scores using a Likert scale, arterial blood gas (ABG) parameters, mask leak, hemodynamic data, and complications.Results

The median comfort score was significantly higher with the bridge-free mask (12 [IQR: 11-14]) than with the conventional mask (10 [IQR: 9-12], P < 0.001). Mask leak was also lower with the bridge-free design. No significant differences were seen in ABG or hemodynamic parameters. Nasal bridge pressure injuries occurred exclusively with conventional masks.Conclusion

The bridge-free oronasal mask provided superior comfort and reduced leak without compromising ventilation efficacy or hemodynamic stability.

Related

  1. Sigh ventilation versus conventional protective ventilation in cardiac surgery: a proof-of-concept randomized controlled trial
    Zhichang Wang, Hui Chen, Tao Chen +12
    Critical CarePeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Comparative outcomes of conventional follitropin delta 15 µg/day versus follitropin alfa 225 IU/day for ovarian stimulation: results from an exploratory post hoc analysis of Spanish participants from the ADAPT-1 randomized controlled trial
    Marta García Sánchez, Andrea Bernabeu, Ana Hernández Cesteros +7
    Frontiers in reproductive healthPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Comparative evaluation of the antipyretic and analgesic efficacy and safety of a fast-release paracetamol 650 mg formulation vs. conventional paracetamol formulations in adults with acute febrile or febrile-pain conditions: a multicenter randomized controlled trial
    Susobhan Mondal, S. K. Ashik Ikbal, Sumit Agrawal +11
    Frontiers in pain research (Lausanne, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Discomfort of noninvasive ventilation, high flow nasal cannula oxygen, and conventional oxygen implemented after extubation in non-COPD patients
    Jean-Jacques Rouby, Jean-Pierre Quenot, Mao Zhang +35
    Critical CarePeer-reviewedCC BY-NC-NDGeneral biologyEpidemiology & public healthHAL
  5. Comparative clinical performance of stainless steel crowns placed using conventional, hall, and modified Hall techniques in carious primary molars: A three-arm parallel-group randomized controlled trial
    K. A. Akshaydeep, Varinder Goyal, Puneet Goyal +3
    Journal of Indian Society of Pedodontics and Preventive DentistryPeer-reviewedCC BY-NC-SAFull textGeneral medicineDOAJ
BibTeX
@article{guravana2026comparative,
  title = {{Comparative analysis of comfort of noninvasive ventilation (NIV) with a conventional oronasal mask and a bridge-free oronasal mask: A randomized controlled trial.}},
  author = {Bhavani Prasad Guravana and Manoj Kamal and Pradeep K Bhatia and Sadik Mohammed and Rakesh Kumar and Anita Chouhan},
  journal = {Journal of anaesthesiology, clinical pharmacology},
  year = {2026},
  month = oct,
  doi = {10.4103/joacp.joacp_733_25},
  url = {https://europepmc.org/article/MED/43048377},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Comparative analysis of comfort of noninvasive ventilation (NIV) with a conventional oronasal mask and a bridge-free oronasal mask: A randomized controlled trial.
AU  - Bhavani Prasad Guravana
AU  - Manoj Kamal
AU  - Pradeep K Bhatia
AU  - Sadik Mohammed
AU  - Rakesh Kumar
AU  - Anita Chouhan
PY  - 2026
DA  - 2026/10/17
JO  - Journal of anaesthesiology, clinical pharmacology
DO  - 10.4103/joacp.joacp_733_25
UR  - https://europepmc.org/article/MED/43048377
AB  - Background and aims  Non-invasive ventilation (NIV) effectiveness depends largely on ventilator settings and interface design. Conventional oronasal masks often exert pressure on the nasal bridge, causing discomfort, skin injury, and poor tolerance, which may lead to NIV failure. Bridge-free oronasal masks eliminate nasal bridge contact and may enhance comfort and overall compliance. This study compared patient comfort, ventilatory performance, and mask-related complications between bridge-free and conventional oronasal masks during NIV.Material and methods  A prospective randomized unblinded controlled crossover trial involving 84 adult patients requiring NIV. Participants were divided into two groups: Group AB received the bridge-free mask for 2 hours followed by a conventional mask for 2 hours, while Group BA received them in reverse order. Data collected included comfort scores using a Likert scale, arterial blood gas (ABG) parameters, mask leak, hemodynamic data, and complications.Results  The median comfort score was significantly higher with the bridge-free mask (12 [IQR: 11-14]) than with the conventional mask (10 [IQR: 9-12], P < 0.001). Mask leak was also lower with the bridge-free design. No significant differences were seen in ABG or hemodynamic parameters. Nasal bridge pressure injuries occurred exclusively with conventional masks.Conclusion  The bridge-free oronasal mask provided superior comfort and reduced leak without compromising ventilation efficacy or hemodynamic stability.
SN  - 0970-9185
SN  - 2231-2730
ER  -