Purpose
To compare procedure time between knotless and knotted all-suture anchors during arthroscopic acetabular labral repair in a cadaveric model and to evaluate implications for surgical training and workflow efficiency.Methods
Ten fresh-frozen cadaveric hemipelvis specimens underwent arthroscopic labral repair. Five specimens (20 anchors) were repaired using knotted all-suture anchors, and 5 specimens (20 anchors) were repaired using tensionable knotless all-suture anchors. A standardized simple-loop suture configuration was used in all repairs. Repair time per anchor was recorded and subdivided into "Pass," "Tie/Convert," and "Cut" phases. Comparisons between groups were performed using independent t tests or Mann-Whitney U tests, with α = 0.05.Results
Mean total repair time per anchor was significantly shorter in the knotless group (79.36 ± 18.07 seconds) compared with the knotted group (142.48 ± 27.96 seconds; P = .007). Tie/Convert phase was also significantly shorter in the knotless group (15.92 ± 4.50 seconds vs 73.11 ± 18.44 seconds; P < .001). Pass phase was slightly longer with knotless anchors (52.94 ± 24.92 seconds vs 43.41 ± 23.83 seconds; P = .050). Cut phase was shorter with knotless anchors (11.35 ± 4.93 seconds vs 25.70 ± 27.06 seconds; P = .191) although not statistically significant.Conclusions
Knotless suture anchors significantly reduced acetabular labral repair time compared with knotted anchors in this cadaveric model, primarily because of a shorter Tie/Convert phase required for suture fixation.Clinical relevance
Knotless suture anchors may streamline labral repair by eliminating arthroscopic knot tying. Their technical simplicity and efficiency may benefit surgical training and enhance consistency among less experienced surgeons.
Related
- Anterolateral Suture Tensioning for Improved Reduction in Arthroscopic Subscapularis Repair With Knotless Anchors
- Double Row Side-to-Side Rotator Cuff Repair With Tensionable Knotless Anchors for Traumatic Transtendinous Supraspinatus Tears.
- Arthroscopic Reduction and Fixation of Impacted Humeral Head Reverse Hill‐Sachs Fracture With Absorbable Anchors for Acute Traumatic Posterior Shoulder Dislocation
- Repair of Posterior Root Medial Meniscus Oblique Tear Repair With Centralized Suture Technique of Inverted Anchors Combined With Fibrin Clot.
- Arthroscopic Saucerization and Anatomic Repair of a Wrisberg Variant Discoid Lateral Meniscus: A Physeal‐Sparing Knotless Anchor Technique
BibTeX
@article{kahanarojkind2026knotless,
title = {{Knotless Suture Anchors Reduce Repair Time in Arthroscopic Hip Labral Repair Compared With Knotted Anchors.}},
author = {Ady H Kahana-Rojkind and Tyler McCarroll and Roger Quesada-Jimenez and Absolon Reyes-Cordova and Dean Sandler and Etan P Sugarman and Benjamin G Domb},
journal = {Arthroscopy, sports medicine, and rehabilitation},
year = {2026},
month = nov,
doi = {10.1002/ars2.70127},
url = {https://europepmc.org/article/MED/43011437},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Knotless Suture Anchors Reduce Repair Time in Arthroscopic Hip Labral Repair Compared With Knotted Anchors.
AU - Ady H Kahana-Rojkind
AU - Tyler McCarroll
AU - Roger Quesada-Jimenez
AU - Absolon Reyes-Cordova
AU - Dean Sandler
AU - Etan P Sugarman
AU - Benjamin G Domb
PY - 2026
DA - 2026/11/09
JO - Arthroscopy, sports medicine, and rehabilitation
DO - 10.1002/ars2.70127
UR - https://europepmc.org/article/MED/43011437
AB - Purpose To compare procedure time between knotless and knotted all-suture anchors during arthroscopic acetabular labral repair in a cadaveric model and to evaluate implications for surgical training and workflow efficiency.Methods Ten fresh-frozen cadaveric hemipelvis specimens underwent arthroscopic labral repair. Five specimens (20 anchors) were repaired using knotted all-suture anchors, and 5 specimens (20 anchors) were repaired using tensionable knotless all-suture anchors. A standardized simple-loop suture configuration was used in all repairs. Repair time per anchor was recorded and subdivided into "Pass," "Tie/Convert," and "Cut" phases. Comparisons between groups were performed using independent t tests or Mann-Whitney U tests, with α = 0.05.Results Mean total repair time per anchor was significantly shorter in the knotless group (79.36 ± 18.07 seconds) compared with the knotted group (142.48 ± 27.96 seconds; P = .007). Tie/Convert phase was also significantly shorter in the knotless group (15.92 ± 4.50 seconds vs 73.11 ± 18.44 seconds; P < .001). Pass phase was slightly longer with knotless anchors (52.94 ± 24.92 seconds vs 43.41 ± 23.83 seconds; P = .050). Cut phase was shorter with knotless anchors (11.35 ± 4.93 seconds vs 25.70 ± 27.06 seconds; P = .191) although not statistically significant.Conclusions Knotless suture anchors significantly reduced acetabular labral repair time compared with knotted anchors in this cadaveric model, primarily because of a shorter Tie/Convert phase required for suture fixation.Clinical relevance Knotless suture anchors may streamline labral repair by eliminating arthroscopic knot tying. Their technical simplicity and efficiency may benefit surgical training and enhance consistency among less experienced surgeons.
SN - 2666-061X
ER -