Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 7 min ago
Peer-reviewedCC BY 4.0Arthroscopy Techniques

Distal Clavicle Plate Combined With EndoButton Device for the Treatment of Neer Type IIB Distal Clavicle Fractures

  1. 1Department of Orthopedics Hospital of PLA 73rd Group Army, Chenggong Hospital Affiliated to Xiamen University Xiamen China

Abstract

The present article describes a surgical technique for the management of Neer type IIB distal clavicle fractures using a distal clavicle plate combined with an EndoButton device. The procedure consists of stepwise arthroscopic evaluation and exposure, fracture reduction, conoid ligament reconstruction, and plate fixation. This combined approach allows for concurrent management of intra‐articular lesions, provides stable fixation, reduces the risk of iatrogenic clavicle fractures, and facilitates early postoperative rehabilitation. Nevertheless, it has certain limitations: the approach is not minimally invasive, its indications are relatively narrow, and it requires advanced arthroscopic expertise. All in all, this surgical approach is applicable to both acute and chronic Neer type IIB distal clavicle fractures.

Related

  1. Immediate weight bearing after dual orthogonal plate fixation of clavicle fractures: a propensity-matched retrospective cohort study
    Andrew Monhollen, Lena Kolostov, Nash Kolb +4
    European Journal of Orthopaedic Surgery & TraumatologyPeer-reviewedCC BY 4.0Full textEpidemiology & public healthPMCEurope PMC
  2. Does minimally invasive plating reduce supraclavicular nerve injury compared with nerve-preserving open plating in clavicle fractures? A systematic review and meta-analysis.
    Chia-You Chou, Chi-Sheng Chien, Wei-Ting Lin
    Journal of orthopaedic surgery and researchPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMCPMC
  3. Functional Outcomes of Midshaft Clavicle Fractures Treated With Plate Osteosynthesis: A Prospective Observational Study
    Brijendra Singh, Rohit Shukla, Shubham Srivastava +2
    CureusPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  4. Orthopaedic Consultation Versus No Consultation for Clavicle, Radial Head, and Proximal Humerus Fractures: Association with Post-Imaging Emergency Department Length of Stay
    Lindsay V. Walsh, Jacob S. Borgida, Austin T. Gregg +7
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  5. Augmented Fixation of Distal Clavicle Fractures: High Union, Moderate Complications.
    Imran Khan, Tahreem Fatima, Kashif Memon +1
    CureusPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
BibTeX
@article{zhu2026distal,
  title = {{Distal Clavicle Plate Combined With EndoButton Device for the Treatment of Neer Type IIB Distal Clavicle Fractures}},
  author = {Tianhao Zhu and Changming Huang and Huaqiang Fan and Xichun Hu and Yangpan Fu and Huixiang Dong and Yaqing Zhang},
  journal = {Arthroscopy Techniques},
  year = {2026},
  month = nov,
  doi = {10.1002/atn2.70379},
  url = {https://doi.org/10.1002/atn2.70379},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Distal Clavicle Plate Combined With EndoButton Device for the Treatment of Neer Type IIB Distal Clavicle Fractures
AU  - Tianhao Zhu
AU  - Changming Huang
AU  - Huaqiang Fan
AU  - Xichun Hu
AU  - Yangpan Fu
AU  - Huixiang Dong
AU  - Yaqing Zhang
PY  - 2026
DA  - 2026/11/03
JO  - Arthroscopy Techniques
DO  - 10.1002/atn2.70379
UR  - https://doi.org/10.1002/atn2.70379
AB  - The present article describes a surgical technique for the management of Neer type IIB distal clavicle fractures using a distal clavicle plate combined with an EndoButton device. The procedure consists of stepwise arthroscopic evaluation and exposure, fracture reduction, conoid ligament reconstruction, and plate fixation. This combined approach allows for concurrent management of intra‐articular lesions, provides stable fixation, reduces the risk of iatrogenic clavicle fractures, and facilitates early postoperative rehabilitation. Nevertheless, it has certain limitations: the approach is not minimally invasive, its indications are relatively narrow, and it requires advanced arthroscopic expertise. All in all, this surgical approach is applicable to both acute and chronic Neer type IIB distal clavicle fractures.
SN  - 2212-6287
ER  -