Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 47 min ago
Peer-reviewedCC BY 4.0Micromachines

Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection

Abstract

Glyphosate is among the most widely used herbicides worldwide, and its extensive application has led to increasing concerns regarding environmental contamination and potential risks to human health. The persistence of this compound in soil and aquatic environments has created an urgent demand for analytical methods that are rapid, reliable, and economically feasible. In the present study, a microconductometric sensing platform was developed for glyphosate determination using a PVC liquid membrane incorporating an [o-COSAN]⁻/glyphosate ion-pair complex deposited onto interdigitated electrodes. The proposed sensor provided a linear analytical response over the concentration range of 1.0 × 10⁻5 to 2.5 × 10⁻3 M, with a detection limit of 4 μM. The device also exhibited excellent analytical performance, with reproducibility and repeatability values of 3% and 8% (RSD), respectively. Furthermore, the sensor maintained stable performance for more than three months and showed a high degree of selectivity toward glyphosate when evaluated against potential interfering compounds, including AMPA and carbofuran. These results demonstrate the potential of the proposed sensing platform as a simple, sensitive, and cost-effective tool for glyphosate monitoring in environmental samples.

Related

  1. Heterologous expression of the membrane protein OmpA from bovine Pasteurella multocida and establishment of an indirect ELISA for antibody detection
    Donghao Hao, Sie Han, Yan Wang +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMicrobiologyCrossref
  2. Genome-wide analysis of plasma membrane H+ -ATPases in Populus tomentosa reveals the roles of PtoPHA14D in regulating adventitious root development
    Run Shi, Xueke Wu, Bin Zhang +5
    Industrial Crops and ProductsPeer-reviewedCC BY-NC-ND6 citedPlant biologyOpenAlex
  3. Rapid recombinase polymerase amplification-based detection of the bar gene for environmental monitoring of genetically modified soybean and rice.
    Areum Jeong, Sung-Dug Oh, Sara Noh +4
    GM crops & foodPeer-reviewedCC BY-NCFull textPlant biologyEurope PMC
  4. TomaNet-6H: towards transparent plant disease detection using a modified CNN with Grad-CAM for tomato leaves
    Shubham Roy, Shakir Khan, Neha Gupta +5
    Frontiers in Plant SciencePeer-reviewedCC BY 4.0Full textPlant biologyCrossrefEurope PMC
  5. Characterization of Low-Level Glyphosate Tolerance in an Abutilon theophrasti Population from a Soybean Field
    Jiabo Dong, Lijun Wang, Xiaofei Ding +6
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
BibTeX
@article{alghamdi2026development,
  title = {{Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection}},
  author = {Youssef Al-Ghamdi and Amani Chrouda and Nicole Jaffrezic-Renault and Hamdi Ben Halima},
  journal = {Micromachines},
  year = {2026},
  month = jul,
  doi = {10.3390/mi17080901},
  url = {https://hal.science/hal-05798389v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection
AU  - Youssef Al-Ghamdi
AU  - Amani Chrouda
AU  - Nicole Jaffrezic-Renault
AU  - Hamdi Ben Halima
PY  - 2026
DA  - 2026/07/27
JO  - Micromachines
DO  - 10.3390/mi17080901
UR  - https://hal.science/hal-05798389v1
AB  - Glyphosate is among the most widely used herbicides worldwide, and its extensive application has led to increasing concerns regarding environmental contamination and potential risks to human health. The persistence of this compound in soil and aquatic environments has created an urgent demand for analytical methods that are rapid, reliable, and economically feasible. In the present study, a microconductometric sensing platform was developed for glyphosate determination using a PVC liquid membrane incorporating an [o-COSAN]⁻/glyphosate ion-pair complex deposited onto interdigitated electrodes. The proposed sensor provided a linear analytical response over the concentration range of 1.0 × 10⁻5 to 2.5 × 10⁻3 M, with a detection limit of 4 μM. The device also exhibited excellent analytical performance, with reproducibility and repeatability values of 3% and 8% (RSD), respectively. Furthermore, the sensor maintained stable performance for more than three months and showed a high degree of selectivity toward glyphosate when evaluated against potential interfering compounds, including AMPA and carbofuran. These results demonstrate the potential of the proposed sensing platform as a simple, sensitive, and cost-effective tool for glyphosate monitoring in environmental samples.
SN  - 2072-666X
ER  -