Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 24 min ago
PreprintarXiv licencearXiv

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

Abstract

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.

Related

  1. Evaluation of a markerless data augmentation algorithm for sports movements
    Axel Koussou, Hanane Ariouat, Sebastien Laporte +1
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  2. Impact of video compression on 3D markerless reconstruction
    Alexandre Naaim, Mathis Renaudin, Denis Brizard +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  3. Sensitivity of kinematics to biomechanical model parameters in markerless motion analysis
    Antoine Muller, Martin Dizier, Mathis Renaudin +1
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  4. Comparative evaluation of three markerless motion capture solutions for lower limb kinematics
    Feriel Drouiche, Junliang Cao, Theophile Cocquerez +1
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  5. Accuracy of Markerless Pose Estimation for Pediatric Upper Limb Kinematics During Daily Living Activities
    Julie Rozaire, Mickael Begon, Yosra Cherni +1
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
BibTeX
@misc{delaplace2026videobased,
  title = {{Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods}},
  author = {Florian Delaplace and Elodie Piche and Frédéric Chorin and Raphael Zory},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.18667},
  eprint = {2609.18667},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.18667},
}
RIS
TY  - UNPB
TI  - Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods
AU  - Florian Delaplace
AU  - Elodie Piche
AU  - Frédéric Chorin
AU  - Raphael Zory
PY  - 2026
DA  - 2026/09/16
PB  - arXiv
DO  - 10.48550/arxiv.2609.18667
UR  - https://arxiv.org/abs/2609.18667
AB  - Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.
ER  -