Concordance Study on Molecular Detection of Thyroid Nodules by Ultrasound Guided Fine Needle Aspiration
4 affiliations
- 1Department of Thyroid and Breast The Second Affiliated Hospital of Soochow University Suzhou China
- 2Advanced Molecular Pathology Institute of Soochow University and SANO Suzhou China
- 3Suzhou SANO Precision Medicine Ltd SANO Medical Laboratories Suzhou China
- 4Department of Pathology The Second Affiliated Hospital of Soochow University Suzhou China
Abstract
Background: Fine needle aspiration (FNA) constitutes the primary preoperative evaluation for thyroid nodules. Targeted Next‐generation sequencing (NGS) of FNA samples increasingly informs clinical assessment. Molecular concordance between FNA and surgical tissues may be modulated by lesion diameter and heterogeneity.
Methods: Among 91 prospectively enrolled patients with suspected thyroid nodules, FNA–fresh surgical tissue matching yielded 76 patients per cohort: 85 matched pairs for DNA NGS, 82 pairs from 72 patients for RNA NGS after four pairs failed library construction. Concordance was assessed by Cohen's kappa, positive (PPA) and negative (NPA) percent agreement; generalized estimating equations and patient‐level cluster bootstrap addressed within‐patient clustering.
Results: DNA NGS concordance was 88.24% (κ = 0.60, cluster‐adjusted 95% CI: 0.37–0.79; PPA 89.04%, NPA 83.33%); RNA NGS concordance was 98.78% (κ = 0.88, 95% CI: 0.54–1.00). DNA yield was higher in surgical tissue than FNA (p < 0.0001); library yield did not differ (p = 0.376). Lesion diameter was comparable between concordant and discordant pairs (p = 0.840; minimum detectable effect d ≈0.95). Concordance did not differ between solitary‐ and multiple‐nodule specimens (p = 0.418) or between malignant and benign lesions on both platforms, although patient‐level discordance was numerically higher in multinodular disease (37.5% vs. 10.3%).
Conclusion: Inter‐specimen concordance is driven mainly by tumor heterogeneity; lesion diameter is unlikely to be a major determinant. Tumor cell proportion, though unquantified, remains a plausible contributor. Surgical tissue yields richer profiles but is not a perfect reference. Standardized FNA sampling and separate puncture of each suspicious nodule may improve concordance.
Related
- Correlation between ultrasound findings of thyroid imaging reporting and data system II and III thyroid nodules and fine-needle aspiration results
- High concordance in molecular profiles between primary tumors and matched lymph node metastases in differentiated thyroid carcinoma: implications for clinical sample selection
- Ultrasound-guided percutaneous fine-needle aspiration in parapharyngeal space lesions: a critical appraisal with illustrative cases
- Cytology smears from endobronchial ultrasound-guided transbronchial needle aspiration as a source of nucleic acids with adequate yield for next-generation sequencing
- US-Guided Fine-Needle Aspiration of Papillary Thyroid Microcarcinoma in Non-Screening Settings: Diagnostic Errors and Mitigation Strategies
BibTeX
@article{meng2026concordance,
title = {{Concordance Study on Molecular Detection of Thyroid Nodules by Ultrasound Guided Fine Needle Aspiration}},
author = {Su Meng and Jianxiong Sun and Changliang Zhang and Zhixue Yang and Jinrong Wei and Si Chen and Yanan Li and Xiaoxiao Dai and Guoqin Jiang},
journal = {Journal of Clinical Laboratory Analysis},
year = {2026},
month = oct,
doi = {10.1002/jcla.70391},
url = {https://doi.org/10.1002/jcla.70391},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Concordance Study on Molecular Detection of Thyroid Nodules by Ultrasound Guided Fine Needle Aspiration
AU - Su Meng
AU - Jianxiong Sun
AU - Changliang Zhang
AU - Zhixue Yang
AU - Jinrong Wei
AU - Si Chen
AU - Yanan Li
AU - Xiaoxiao Dai
AU - Guoqin Jiang
PY - 2026
DA - 2026/10/27
JO - Journal of Clinical Laboratory Analysis
DO - 10.1002/jcla.70391
UR - https://doi.org/10.1002/jcla.70391
AB - Background: Fine needle aspiration (FNA) constitutes the primary preoperative evaluation for thyroid nodules. Targeted Next‐generation sequencing (NGS) of FNA samples increasingly informs clinical assessment. Molecular concordance between FNA and surgical tissues may be modulated by lesion diameter and heterogeneity. Methods: Among 91 prospectively enrolled patients with suspected thyroid nodules, FNA–fresh surgical tissue matching yielded 76 patients per cohort: 85 matched pairs for DNA NGS, 82 pairs from 72 patients for RNA NGS after four pairs failed library construction. Concordance was assessed by Cohen's kappa, positive (PPA) and negative (NPA) percent agreement; generalized estimating equations and patient‐level cluster bootstrap addressed within‐patient clustering. Results: DNA NGS concordance was 88.24% (κ = 0.60, cluster‐adjusted 95% CI: 0.37–0.79; PPA 89.04%, NPA 83.33%); RNA NGS concordance was 98.78% (κ = 0.88, 95% CI: 0.54–1.00). DNA yield was higher in surgical tissue than FNA (p < 0.0001); library yield did not differ (p = 0.376). Lesion diameter was comparable between concordant and discordant pairs (p = 0.840; minimum detectable effect d ≈0.95). Concordance did not differ between solitary‐ and multiple‐nodule specimens (p = 0.418) or between malignant and benign lesions on both platforms, although patient‐level discordance was numerically higher in multinodular disease (37.5% vs. 10.3%). Conclusion: Inter‐specimen concordance is driven mainly by tumor heterogeneity; lesion diameter is unlikely to be a major determinant. Tumor cell proportion, though unquantified, remains a plausible contributor. Surgical tissue yields richer profiles but is not a perfect reference. Standardized FNA sampling and separate puncture of each suspicious nodule may improve concordance.
SN - 0887-8013
SN - 1098-2825
ER -