Development of a 2D Ti
- 1Centre for Nanotechnology Research, Vellore Institute of Technology, Vellore, 632014, Tamil Nadu, India
- 2Corresponding author.
Abstract
Bisphenol A (BPA) is a widely used plastic monomers that acts as an endocrine disruptor, making its rapid and sensitive detection important for food safety and environmental monitoring. In this study, two-dimensional Ti 3 CNT x MXene was synthesized from its Ti 3 AlCN MAX phase precursor by a one-step wet chemical etching route and used to modify a glassy carbon electrode (GCE) for electrochemical BPA sensing. XRD, Raman, FESEM, and HRTEM confirmed the successful conversion of the MAX phase into few-layer, accordion-like MXene sheets with nitrogen incorporated into the carbide lattice, yielding a specific surface area of 66.99 m 2 g − 1 . High-resolution XPS verified lattice-level nitrogen integration through characteristic N ‐ Ti core bonds ( 398.25 eV ) and complete removal of the aluminium layers. Zeta potential measurements across pH 4 − 9 demonstrated an anionic surface charge ( − 11.9 mV to − 39.4 mV ), with a stable potential of − 31.4 mV at pH 7.0 confirming good colloidal stability and abundant functional groups. Compared with Ti 3 C 2 T x MXene, its MAX phase precursors, and bare GCE, the Ti 3 CNT x /GCE showed the highest peak current, smallest peak separation, and lowest charge-transfer resistance toward the [Fe (CN) 6 ] 3- / 4- redox probe, indicating faster electron-transfer kinetics and a larger electroactive surface area. Under optimized conditions (pH 7.0, adsorption-controlled oxidation), the sensor detected BPA over a linear range of 0.24–18.53 μM with a limit of detection of 0.99 μM using square wave voltammetry. The sensor also showed good selectivity against structurally similar phenolic compounds and common interfering ions and gave recoveries of 95.8–99.9% when applied to spiked milk and thermal paper receipts samples. These results demonstrate that Ti 3 CNT x MXene is a promising electrode material for the practical, on-site electrochemical detection of BPA in real sample matrices.
BibTeX
@article{bhaskar2026development,
title = {{Development of a 2D Ti}},
author = {Adwaida Bhaskar and Vimala Raghavan},
journal = {Results in Surfaces and Interfaces},
year = {2026},
month = nov,
doi = {10.1016/j.rsurfi.2026.101061},
url = {https://doi.org/10.1016/j.rsurfi.2026.101061},
note = {CC BY},
}
RIS
TY - JOUR
TI - Development of a 2D Ti
AU - Adwaida Bhaskar
AU - Vimala Raghavan
PY - 2026
DA - 2026/11/26
JO - Results in Surfaces and Interfaces
DO - 10.1016/j.rsurfi.2026.101061
UR - https://doi.org/10.1016/j.rsurfi.2026.101061
AB - Bisphenol A (BPA) is a widely used plastic monomers that acts as an endocrine disruptor, making its rapid and sensitive detection important for food safety and environmental monitoring. In this study, two-dimensional Ti 3 CNT x MXene was synthesized from its Ti 3 AlCN MAX phase precursor by a one-step wet chemical etching route and used to modify a glassy carbon electrode (GCE) for electrochemical BPA sensing. XRD, Raman, FESEM, and HRTEM confirmed the successful conversion of the MAX phase into few-layer, accordion-like MXene sheets with nitrogen incorporated into the carbide lattice, yielding a specific surface area of 66.99 m 2 g − 1 . High-resolution XPS verified lattice-level nitrogen integration through characteristic N ‐ Ti core bonds ( 398.25 eV ) and complete removal of the aluminium layers. Zeta potential measurements across pH 4 − 9 demonstrated an anionic surface charge ( − 11.9 mV to − 39.4 mV ), with a stable potential of − 31.4 mV at pH 7.0 confirming good colloidal stability and abundant functional groups. Compared with Ti 3 C 2 T x MXene, its MAX phase precursors, and bare GCE, the Ti 3 CNT x /GCE showed the highest peak current, smallest peak separation, and lowest charge-transfer resistance toward the [Fe (CN) 6 ] 3- / 4- redox probe, indicating faster electron-transfer kinetics and a larger electroactive surface area. Under optimized conditions (pH 7.0, adsorption-controlled oxidation), the sensor detected BPA over a linear range of 0.24–18.53 μM with a limit of detection of 0.99 μM using square wave voltammetry. The sensor also showed good selectivity against structurally similar phenolic compounds and common interfering ions and gave recoveries of 95.8–99.9% when applied to spiked milk and thermal paper receipts samples. These results demonstrate that Ti 3 CNT x MXene is a promising electrode material for the practical, on-site electrochemical detection of BPA in real sample matrices.
SN - 2666-8459
ER -