Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 53 min ago
Peer-reviewedCC BY 4.0Frontiers in Artificial Intelligence

Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification

  1. 1School of Electronics Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, India
  2. 2Computer Science and Engineering Indian Institute of Information Technology, Kottayam, Kerala, India

Abstract

Models for colorectal polyp classification lose accuracy when applied to images from a different clinical center, and training on the low-frequency approximation subband of a discrete wavelet transform has been proposed as a remedy. We set out to test that hypothesis on Kvasir-SEG and PICCOLO, and report instead that three measurement practices common in this literature do not support the conclusions drawn from them. First, a single-level Haar LL subband is arithmetically identical to grayscale conversion followed by 2× decimation, verified to floating-point precision on both random and endoscopic data. At one decomposition level, wavelet decomposition and resolution reduction are not separable hypotheses, and the proposed mechanism is therefore not well-formed as posed. Second, image-level splitting—the standard remedy for patch-level leakage—is insufficient for video-derived datasets. PICCOLO's 3,433 frames derive from 70 physical lesions in 40 examinations; an image-level split leaves 58 of those lesions and 37 of those videos shared between training and test, and in-distribution AUC falls by 0.054 when measured against the partition the dataset authors supply. Third, the intersection-over-union metric used to assess attention localization inverts on high-coverage patches, where a polyp patch is almost entirely polyp: random attention scores 0.59 against 0.24 for trained heads. Measured without the area confound, localization is real but weak and confined to particular heads. We additionally quantify a reproducibility floor. In small models trained from scratch, runs receiving bit-identical inputs diverge by up to 0.177 AUC in the CNN/PICCOLO row through early-stopping checkpoint selection, and in one experimental arm this null control is itself statistically significant, so no claim from that arm is supportable at any p-value. A color-removal benefit observed in this regime (+0.067 AUC, 95% CI [+0.037, +0.097]) does not replicate on ImageNet-pretrained ResNet-18 and DeiT-Tiny backbones, where intervals exclude effects a fifth its size. We recommend reporting a null control alongside every comparison, and show that this identifies arms in which no claim can be supported.

Related

  1. An efficient brain tumor classification system with accurate recognition and complementary downsampling blocks
    Jincan Zhang, Chuanqi Cai, XingHua Tan +4
    PLOS OnePeer-reviewedCC BY 4.0Full textMedical imaging & radiologyOncologyPLOS
  2. PV-WTConv: a parallel network for abnormal white blood cell classification based on wavelet transform convolution
    Xiangsuo Fan, Xipeng Song, Borui Sun +2
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMCEurope PMC
  3. WEM-Mamba: a Wavelet-Enhanced MedMamba framework for rotator cuff tear classification in X-ray images.
    Zheng Wang, Zhen Liu, Jiashun Li +7
    BMC medical imagingPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Clinical classification of Hill-Sachs lesions: a systematic review of radiographic measurement techniques
    Owen T. Kennedy, William Yang, Shrishti Jain +9
    JSES reviews, reports, and techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. IFRS 9 Measurement Pressure, Classification Choices, and Financial Sustainability: The Moderating Role of State Ownership in Egyptian Banks
    Sherif Nayel, Khaled Hegazy
    ERU Research JournalPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{jenifer2026singlelevel,
  title = {{Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification}},
  author = {Jenifer R. and Dhimant Tewari and Goutham Veerapu and Nisha J. S. and Gopinath Palanisamy and Saanji Kohli},
  journal = {Frontiers in Artificial Intelligence},
  year = {2026},
  month = nov,
  doi = {10.3389/frai.2026.1929384},
  url = {https://doi.org/10.3389/frai.2026.1929384},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification
AU  - Jenifer R.
AU  - Dhimant Tewari
AU  - Goutham Veerapu
AU  - Nisha J. S.
AU  - Gopinath Palanisamy
AU  - Saanji Kohli
PY  - 2026
DA  - 2026/11/09
JO  - Frontiers in Artificial Intelligence
DO  - 10.3389/frai.2026.1929384
UR  - https://doi.org/10.3389/frai.2026.1929384
AB  - Models for colorectal polyp classification lose accuracy when applied to images from a different clinical center, and training on the low-frequency approximation subband of a discrete wavelet transform has been proposed as a remedy. We set out to test that hypothesis on Kvasir-SEG and PICCOLO, and report instead that three measurement practices common in this literature do not support the conclusions drawn from them. First, a single-level Haar LL subband is arithmetically identical to grayscale conversion followed by 2× decimation, verified to floating-point precision on both random and endoscopic data. At one decomposition level, wavelet decomposition and resolution reduction are not separable hypotheses, and the proposed mechanism is therefore not well-formed as posed. Second, image-level splitting—the standard remedy for patch-level leakage—is insufficient for video-derived datasets. PICCOLO's 3,433 frames derive from 70 physical lesions in 40 examinations; an image-level split leaves 58 of those lesions and 37 of those videos shared between training and test, and in-distribution AUC falls by 0.054 when measured against the partition the dataset authors supply. Third, the intersection-over-union metric used to assess attention localization inverts on high-coverage patches, where a polyp patch is almost entirely polyp: random attention scores 0.59 against 0.24 for trained heads. Measured without the area confound, localization is real but weak and confined to particular heads. We additionally quantify a reproducibility floor. In small models trained from scratch, runs receiving bit-identical inputs diverge by up to 0.177 AUC in the CNN/PICCOLO row through early-stopping checkpoint selection, and in one experimental arm this null control is itself statistically significant, so no claim from that arm is supportable at any p-value. A color-removal benefit observed in this regime (+0.067 AUC, 95% CI [+0.037, +0.097]) does not replicate on ImageNet-pretrained ResNet-18 and DeiT-Tiny backbones, where intervals exclude effects a fifth its size. We recommend reporting a null control alongside every comparison, and show that this identifies arms in which no claim can be supported.
SN  - 2624-8212
ER  -