Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification
- 1School of Electronics Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, India
- 2Computer Science and Engineering Indian Institute of Information Technology, Kottayam, Kerala, India
Abstract
Models for colorectal polyp classification lose accuracy when applied to images from a different clinical center, and training on the low-frequency approximation subband of a discrete wavelet transform has been proposed as a remedy. We set out to test that hypothesis on Kvasir-SEG and PICCOLO, and report instead that three measurement practices common in this literature do not support the conclusions drawn from them. First, a single-level Haar LL subband is arithmetically identical to grayscale conversion followed by 2× decimation, verified to floating-point precision on both random and endoscopic data. At one decomposition level, wavelet decomposition and resolution reduction are not separable hypotheses, and the proposed mechanism is therefore not well-formed as posed. Second, image-level splitting—the standard remedy for patch-level leakage—is insufficient for video-derived datasets. PICCOLO's 3,433 frames derive from 70 physical lesions in 40 examinations; an image-level split leaves 58 of those lesions and 37 of those videos shared between training and test, and in-distribution AUC falls by 0.054 when measured against the partition the dataset authors supply. Third, the intersection-over-union metric used to assess attention localization inverts on high-coverage patches, where a polyp patch is almost entirely polyp: random attention scores 0.59 against 0.24 for trained heads. Measured without the area confound, localization is real but weak and confined to particular heads. We additionally quantify a reproducibility floor. In small models trained from scratch, runs receiving bit-identical inputs diverge by up to 0.177 AUC in the CNN/PICCOLO row through early-stopping checkpoint selection, and in one experimental arm this null control is itself statistically significant, so no claim from that arm is supportable at any p-value. A color-removal benefit observed in this regime (+0.067 AUC, 95% CI [+0.037, +0.097]) does not replicate on ImageNet-pretrained ResNet-18 and DeiT-Tiny backbones, where intervals exclude effects a fifth its size. We recommend reporting a null control alongside every comparison, and show that this identifies arms in which no claim can be supported.
Related
- An efficient brain tumor classification system with accurate recognition and complementary downsampling blocks
- PV-WTConv: a parallel network for abnormal white blood cell classification based on wavelet transform convolution
- WEM-Mamba: a Wavelet-Enhanced MedMamba framework for rotator cuff tear classification in X-ray images.
- Clinical classification of Hill-Sachs lesions: a systematic review of radiographic measurement techniques
- IFRS 9 Measurement Pressure, Classification Choices, and Financial Sustainability: The Moderating Role of State Ownership in Egyptian Banks
BibTeX
@article{jenifer2026singlelevel,
title = {{Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification}},
author = {Jenifer R. and Dhimant Tewari and Goutham Veerapu and Nisha J. S. and Gopinath Palanisamy and Saanji Kohli},
journal = {Frontiers in Artificial Intelligence},
year = {2026},
month = nov,
doi = {10.3389/frai.2026.1929384},
url = {https://doi.org/10.3389/frai.2026.1929384},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification
AU - Jenifer R.
AU - Dhimant Tewari
AU - Goutham Veerapu
AU - Nisha J. S.
AU - Gopinath Palanisamy
AU - Saanji Kohli
PY - 2026
DA - 2026/11/09
JO - Frontiers in Artificial Intelligence
DO - 10.3389/frai.2026.1929384
UR - https://doi.org/10.3389/frai.2026.1929384
AB - Models for colorectal polyp classification lose accuracy when applied to images from a different clinical center, and training on the low-frequency approximation subband of a discrete wavelet transform has been proposed as a remedy. We set out to test that hypothesis on Kvasir-SEG and PICCOLO, and report instead that three measurement practices common in this literature do not support the conclusions drawn from them. First, a single-level Haar LL subband is arithmetically identical to grayscale conversion followed by 2× decimation, verified to floating-point precision on both random and endoscopic data. At one decomposition level, wavelet decomposition and resolution reduction are not separable hypotheses, and the proposed mechanism is therefore not well-formed as posed. Second, image-level splitting—the standard remedy for patch-level leakage—is insufficient for video-derived datasets. PICCOLO's 3,433 frames derive from 70 physical lesions in 40 examinations; an image-level split leaves 58 of those lesions and 37 of those videos shared between training and test, and in-distribution AUC falls by 0.054 when measured against the partition the dataset authors supply. Third, the intersection-over-union metric used to assess attention localization inverts on high-coverage patches, where a polyp patch is almost entirely polyp: random attention scores 0.59 against 0.24 for trained heads. Measured without the area confound, localization is real but weak and confined to particular heads. We additionally quantify a reproducibility floor. In small models trained from scratch, runs receiving bit-identical inputs diverge by up to 0.177 AUC in the CNN/PICCOLO row through early-stopping checkpoint selection, and in one experimental arm this null control is itself statistically significant, so no claim from that arm is supportable at any p-value. A color-removal benefit observed in this regime (+0.067 AUC, 95% CI [+0.037, +0.097]) does not replicate on ImageNet-pretrained ResNet-18 and DeiT-Tiny backbones, where intervals exclude effects a fifth its size. We recommend reporting a null control alongside every comparison, and show that this identifies arms in which no claim can be supported.
SN - 2624-8212
ER -