Patient Posture-Adaptive Non-Contact Respiratory Rate Measurement Inside a Moving Ambulance Using RGB and Thermal Cameras.

4 affiliations
  1. 1Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, 1-33, Yayoicho, Inage-ku, Chiba-shi 263-8522, Chiba, Japan.
  2. 2Department of Emergency and Critical Care Medicine, Graduate School of Medicine, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-shi 260-8670, Chiba, Japan.
  3. 3Department of Obstetrics and Gynecology, Chiba University Hospital, 1-8-1, Inohana, Chuo-ku, Chiba-shi 260-8677, Chiba, Japan.
  4. 4Center for Frontier Medical Engineering, Chiba University, 1-33, Yayoicho, Inage-ku, Chiba-shi 263-8522, Chiba, Japan.

Abstract

Background/Objectives: Monitoring and evaluating respiratory rate (RR) plays a critical role during emergency transport. Conventional RR measurement methods have primarily relied on electrocardiogram-based approaches, which are susceptible to large errors caused by patient body movement and impose a burden on patients due to their contact-based nature. This study aimed to develop a non-contact RR measurement method using RGB and thermal cameras that can be applied inside a moving ambulance. Methods: One of the key challenges in non-contact RR measurement inside an ambulance is accommodating changes in patient posture. We addressed this by patient posture-adaptive automatic image registration between RGB and thermal cameras and developing a nostril detection method robust to posture changes. Results: The image registration error of the proposed method was evaluated at various distances from the camera, and the error was confirmed to remain within 1 pixel. RR measurement experiments simulating various respiratory conditions were then conducted inside a moving ambulance. The average of mean absolute error (MAE) was 0.95, 0.59, and 2.80 breaths per minute (breaths/min) for bradypnea, normal, and tachypnea, respectively, in the supine position, and 1.08, 1.90, and 4.38 breaths/min, respectively, in the semi-sitting position. Evaluation of the proposed nostril detection method further confirmed improved RR estimation accuracy compared with the conventional method. Conclusions: This study achieved patient posture-adaptive automatic image registration and robust nostril detection and successfully conducted experiments under realistic and challenging conditions, representing a substantial step toward the real-world implementation of a non-contact RR measurement system in ambulances.

Related

  1. Effect of the Seated Posture on Segmental Posturo-Respiratory Coupling
    Clara Giordano, Rémi Valentin, Louis Clavel +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textCardiovascular medicineHAL
  2. Myxoedema Coma With Type 2 Respiratory Failure and Hypothermia in an Oedematous Patient: A Case Report
    Basit Khan, Amal Qaisar, Olivia Owen +1
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Non-intubated Video-Assisted Thoracoscopic Pleurodesis Under Paravertebral Block in a Patient With Fibrotic Hypersensitivity Pneumonitis and Chronic Respiratory Failure
    Afonso Borges de Castro, Rita Tavares de Pina, Miguel Ferreira +1
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Cross-cultural adaptation and comparative psychometric evaluation of four patient-reported outcome measures for breast cancer-related lymphedema: measurement properties and clinical discrimination
    Yue Zhou, Yun Li, Qi Zhang +11
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Advancing Patient‐Centred AI With Adaptive Machine Learning
    Dimitrios Kalogeropoulos, Paul Barach, Andrea Downing +2
    Cancer medicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{nemoto2026patient,
  title = {{Patient Posture-Adaptive Non-Contact Respiratory Rate Measurement Inside a Moving Ambulance Using RGB and Thermal Cameras.}},
  author = {Daiga Nemoto and Nozomi Takahashi and Fumitaka Mukouyama and Taka-Aki Nakada and Yukihiro Nomura and Toshiya Nakaguchi},
  journal = {Diagnostics (Basel, Switzerland)},
  year = {2026},
  month = oct,
  doi = {10.3390/diagnostics16193244},
  url = {https://europepmc.org/article/MED/42882399},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Patient Posture-Adaptive Non-Contact Respiratory Rate Measurement Inside a Moving Ambulance Using RGB and Thermal Cameras.
AU  - Daiga Nemoto
AU  - Nozomi Takahashi
AU  - Fumitaka Mukouyama
AU  - Taka-Aki Nakada
AU  - Yukihiro Nomura
AU  - Toshiya Nakaguchi
PY  - 2026
DA  - 2026/10/08
JO  - Diagnostics (Basel, Switzerland)
DO  - 10.3390/diagnostics16193244
UR  - https://europepmc.org/article/MED/42882399
AB  - Background/Objectives: Monitoring and evaluating respiratory rate (RR) plays a critical role during emergency transport. Conventional RR measurement methods have primarily relied on electrocardiogram-based approaches, which are susceptible to large errors caused by patient body movement and impose a burden on patients due to their contact-based nature. This study aimed to develop a non-contact RR measurement method using RGB and thermal cameras that can be applied inside a moving ambulance. Methods: One of the key challenges in non-contact RR measurement inside an ambulance is accommodating changes in patient posture. We addressed this by patient posture-adaptive automatic image registration between RGB and thermal cameras and developing a nostril detection method robust to posture changes. Results: The image registration error of the proposed method was evaluated at various distances from the camera, and the error was confirmed to remain within 1 pixel. RR measurement experiments simulating various respiratory conditions were then conducted inside a moving ambulance. The average of mean absolute error (MAE) was 0.95, 0.59, and 2.80 breaths per minute (breaths/min) for bradypnea, normal, and tachypnea, respectively, in the supine position, and 1.08, 1.90, and 4.38 breaths/min, respectively, in the semi-sitting position. Evaluation of the proposed nostril detection method further confirmed improved RR estimation accuracy compared with the conventional method. Conclusions: This study achieved patient posture-adaptive automatic image registration and robust nostril detection and successfully conducted experiments under realistic and challenging conditions, representing a substantial step toward the real-world implementation of a non-contact RR measurement system in ambulances.