Skip to content
DraconiticResearch
Search Sources API
179,152 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BY-NC-ND 4.0United European Gastroenterology Journal

Artificial Intelligence Versus Conventional Scoring for Assessing Small Bowel Capsule Endoscopy Cleanliness in Crohn's Disease

1 more authors

Abstract

Background and aims: Evaluation of cleanliness in capsule endoscopy is essential to validate the exam. However, reliable evaluation of bowel cleanliness remains challenging. The validated KODA score provides robust assessment but is time-consuming and impractical in routine practice. We aimed to evaluate the performance of an AI-based tool (AXAROlite, Augmented Endoscopy) compared with the KODA score for assessing small bowel cleanliness in CD patients. Methods: This was a post hoc analysis of a multicenter randomized controlled trial (NCT05117996) including 142 CD patients undergoing SBCE after either a standard PEG-based or simplified clear liquid preparation. All videos were evaluated for cleanliness using the KODA score by trained readers. The same videos were analyzed using the AI-based AXAROlite tool. Correlation, agreement, and diagnostic performance of AXAROlite were compared with the KODA score. Clinical factors influencing AI-assessed cleanliness were also investigated. Results: AXAROlite and KODA showed strong correlation for whole small bowel (ρ = 0.61; p < 0.001). AXAROlite demonstrated excellent diagnostic accuracy for detecting adequate cleanliness defined as KODA > 2.25 (AUROC = 0.85, 95% CI 0.79-0.92), with an optimal threshold of 72% clean frames (sensitivity 86%, specificity 72%). Mean cleanliness decreased progressively from proximal to distal small bowel with both methods (p = 0.001). The AXROlite score was independently reduced in patients with active disease and a longer small bowel transit time. Conclusions: AXAROlite provides a rapid, fully automated, and accurate evaluation of small bowel cleanliness in CD, comparable to the validated KODA score. Its integration into routine workflows may streamline reporting and reduce inter-observer variability.

Related

  1. Assessing spoken discourse in aphasia using multimodal artificial intelligence
    M. J. Marte, S. H. Lee, S. Wang +9
    medRxivPreprintCC BY-NC-NDFull textNeurosciencemedRxiv
  2. The use of artificial intelligence in assessing fever in the returning traveller: A scoping review
    Bhavya Gandhi, Leo Morjaria, Imeth Illamperuma +2
    PLOS Digital HealthPeer-reviewedCC BY 4.0Full textNeuroscienceEpidemiology & public healthPLOS
  3. Facial cleanliness, environmental factors, and the burden of trachoma in a pastoral conflict area of Tiaty East, Baringo County, Kenya
    Loise Wanjira Njogu, George A. Makalliwa, Bridget Kimani +5
    PLOS Global Public HealthPeer-reviewedCC BY 4.0Full textGeneral biologyEpidemiology & public healthPLOSPMC
  4. Growing up with artificial intelligence: An amplifier of inequalities and a public health issue
    Théo Mouhoud, Thierry Baubet
    L'EncéphalePeer-reviewedPublisher termsFull textGeneral biologyPsychiatry & mental healthHAL
  5. Notification: Artificial Intelligence in Autism Spectrum Disorder Diagnosis: A Scoping Review of Face, Voice, and Text Analysis Methods.
    Health science reportsPeer-reviewedCC BYFull textNeuroscienceEurope PMCPMC
BibTeX
@article{rouveyre2026artificial,
  title = {{Artificial Intelligence Versus Conventional Scoring for Assessing Small Bowel Capsule Endoscopy Cleanliness in Crohn's Disease}},
  author = {Raphaëlle Rouveyre and Catherine Le Berre and Romain Leenhardt and Michael Collins and Astrid de Massin and Mathurin Flamant and Caroline Trang-Poisson and Guillaume Bouguen and Nina Dib and Aymeric Histace and Theo Soude and Xavier Dray and Arnaud Bourreille},
  journal = {United European Gastroenterology Journal},
  year = {2026},
  month = jun,
  doi = {10.1002/ueg2.70242},
  url = {https://hal.science/hal-05664789v1},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Artificial Intelligence Versus Conventional Scoring for Assessing Small Bowel Capsule Endoscopy Cleanliness in Crohn's Disease
AU  - Raphaëlle Rouveyre
AU  - Catherine Le Berre
AU  - Romain Leenhardt
AU  - Michael Collins
AU  - Astrid de Massin
AU  - Mathurin Flamant
AU  - Caroline Trang-Poisson
AU  - Guillaume Bouguen
AU  - Nina Dib
AU  - Aymeric Histace
AU  - Theo Soude
AU  - Xavier Dray
AU  - Arnaud Bourreille
PY  - 2026
DA  - 2026/06/09
JO  - United European Gastroenterology Journal
DO  - 10.1002/ueg2.70242
UR  - https://hal.science/hal-05664789v1
AB  - Background and aims: Evaluation of cleanliness in capsule endoscopy is essential to validate the exam. However, reliable evaluation of bowel cleanliness remains challenging. The validated KODA score provides robust assessment but is time-consuming and impractical in routine practice. We aimed to evaluate the performance of an AI-based tool (AXAROlite, Augmented Endoscopy) compared with the KODA score for assessing small bowel cleanliness in CD patients. Methods: This was a post hoc analysis of a multicenter randomized controlled trial (NCT05117996) including 142 CD patients undergoing SBCE after either a standard PEG-based or simplified clear liquid preparation. All videos were evaluated for cleanliness using the KODA score by trained readers. The same videos were analyzed using the AI-based AXAROlite tool. Correlation, agreement, and diagnostic performance of AXAROlite were compared with the KODA score. Clinical factors influencing AI-assessed cleanliness were also investigated. Results: AXAROlite and KODA showed strong correlation for whole small bowel (ρ = 0.61; p < 0.001). AXAROlite demonstrated excellent diagnostic accuracy for detecting adequate cleanliness defined as KODA > 2.25 (AUROC = 0.85, 95% CI 0.79-0.92), with an optimal threshold of 72% clean frames (sensitivity 86%, specificity 72%). Mean cleanliness decreased progressively from proximal to distal small bowel with both methods (p = 0.001). The AXROlite score was independently reduced in patients with active disease and a longer small bowel transit time. Conclusions: AXAROlite provides a rapid, fully automated, and accurate evaluation of small bowel cleanliness in CD, comparable to the validated KODA score. Its integration into routine workflows may streamline reporting and reduce inter-observer variability.
SN  - 2050-6406
SN  - 2050-6414
ER  -