Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY 4.0Revista Brasileira de Enfermagem

Reduction of Klebsiella pneumoniae bacterial load after active disinfection of venous catheter connectors

  1. 1University of Dundee. Dundee, Scotland, United Kingdom
  2. 2Universidade Federal de Santa Catarina. Florianópolis, Santa Catarina, Brazil
  3. 3Universidade Federal de São Paulo. São Paulo, São Paulo, Brazil

Abstract

Objective:: to verify the effectiveness of active disinfection in reducing the bacterial load of Klebsiella pneumoniae inoculated in two types of needleless connectors.

Method:: an in vitro experimental study was carried out with 84 experiments. The disinfection treatments used were sterile gauze with 70% ethanol, non-sterile gauze with 70% ethanol, sterile gauze with Incidin®, and a single-use device with 70% isopropanol. Data were analyzed using the Kruskal-Wallis test and Conover’s post-hoc test.

Results:: all disinfection methods were effective. In valved connectors, the greatest reduction in bacterial load was with 70% ethanol (96.56%), and in extension connectors, the reduction was greater than 99% in all disinfection methods.

Conclusions:: the reduction of microbial load in venous access connectors is an important indicator for the prevention of bloodstream infections, in addition to contributing to the promotion of safe practices during nursing care.

Related

  1. Hypervirulent Klebsiella pneumoniae Infections in Vancouver, Canada: A Clinical, Microbiological, and Genetic Retrospective Investigation
    Open forum infectious diseasesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Bloodstream Isolation of Klebsiella Pneumoniae in Adults Hospitalized with SARS-CoV-2 During the Omicron BA.5 Wave: A Retrospective Cohort Study
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. PredKlebAMR: A machine learning framework prioritizing sensitivity in Klebsiella pneumoniae resistance profiling
    Abiola A. Babajide, James Mordecai, Kweku Gyasi +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossref
  4. Community-Acquired Klebsiella pneumoniae Meningitis With Liver Abscess and Neurological Sequelae in an Immunocompetent Adult: A Case Report
    Ghamdan Alsadeh, Sheema T Parakkal, Leyla K Bereka +1
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. L-histidine metabolic reprogramming is associated with imipenem-relebactam resistance in carbapenem-resistant hypervirulent Klebsiella pneumoniae
    Jun Li, Haolan Wang, Yuyao Wang +6
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0General medicineCrossref
BibTeX
@article{biazusdalcin2026reduction,
  title = {{Reduction of Klebsiella pneumoniae bacterial load after active disinfection of venous catheter connectors}},
  author = {Camila Biazus-Dalcin and Thaís Cristine Marques Sincero and Jefferson Wildes da Silva Moura and Thiago Lopes Silva and Aline de Souza Bitencourt and Isadora Silva de Souza and Denise Miyuki Kusahara and Patrícia Kuerten Rocha},
  journal = {Revista Brasileira de Enfermagem},
  year = {2026},
  month = nov,
  doi = {10.1590/0034-7167-2025-0330},
  url = {https://doi.org/10.1590/0034-7167-2025-0330},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Reduction of Klebsiella pneumoniae bacterial load after active disinfection of venous catheter connectors
AU  - Camila Biazus-Dalcin
AU  - Thaís Cristine Marques Sincero
AU  - Jefferson Wildes da Silva Moura
AU  - Thiago Lopes Silva
AU  - Aline de Souza Bitencourt
AU  - Isadora Silva de Souza
AU  - Denise Miyuki Kusahara
AU  - Patrícia Kuerten Rocha
PY  - 2026
DA  - 2026/11/06
JO  - Revista Brasileira de Enfermagem
DO  - 10.1590/0034-7167-2025-0330
UR  - https://doi.org/10.1590/0034-7167-2025-0330
AB  - Objective:: to verify the effectiveness of active disinfection in reducing the bacterial load of Klebsiella pneumoniae inoculated in two types of needleless connectors.  Method:: an in vitro experimental study was carried out with 84 experiments. The disinfection treatments used were sterile gauze with 70% ethanol, non-sterile gauze with 70% ethanol, sterile gauze with Incidin®, and a single-use device with 70% isopropanol. Data were analyzed using the Kruskal-Wallis test and Conover’s post-hoc test.  Results:: all disinfection methods were effective. In valved connectors, the greatest reduction in bacterial load was with 70% ethanol (96.56%), and in extension connectors, the reduction was greater than 99% in all disinfection methods.  Conclusions:: the reduction of microbial load in venous access connectors is an important indicator for the prevention of bloodstream infections, in addition to contributing to the promotion of safe practices during nursing care.
SN  - 0034-7167
SN  - 1984-0446
ER  -