Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 43 min ago
Peer-reviewedCC BY-NC-NDBiomedical engineering online

Computational analysis of a high-density electrode to scale the electric field geometry and intensity for neurostimulation.

  1. 1Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, 14260, USA.
  2. 2Department of Biology, Cornell University, Ithaca, NY, 14850, USA.
  3. 3Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, 14260, USA. [email protected].

Abstract

High-density grid electrodes can be configured to spatially scale the neurostimulation fields and enable the control of depth, intensity, and stimulation vectoring. In this study, we computationally analyze a high-density cluster electrode (HDCE) technology to measure its scalability and its effects on human tissue. The models are developed in Ansys using the Maxwell 3D Design modeler. More than 24 HDCE electrode configurations were analyzed and compared to standard 8 mm Ag/AgCl electrodes. It was found that the HDCE electrode configurations can be selected to emulate the electric field properties to within 1% of a standard 8 mm Ag/AgCl electrode. Moreover, increasing the number of active electrode contacts in the HDCE non-linearly increases tissue voltage and field intensity at various tissue depths. Specifically, it was found that the sensitivity of tissue voltage and field intensity decreases with the number of active HDCE electrode contacts. Similarly, the different spatial configurations of the HDCE can change the field shape by up to 54%, while the field intensity can be scaled by up to 186%. Similarly, the vector of the stimulation field (i.e., stimulation vector) through the tissues can be adjusted by shifting active electrode positions. When comparing these electrodes to standard 8 mm Ag/AgCl electrodes the results suggest a transformative impact of these technologies to optimize neurostimulation applications. The work presented here is part of a larger project aiming to develop next-generation scalable neurostimulation system that improve rehabilitation outcomes, and provide new adaptive solutions for personalized healthcare.

Related

  1. NANHA - Neurostimulation in Atypical Neurodevelopment: a Harmonized Atlas
    M. Mondal, C. Guha, S. A. Suresh +3
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  2. Neurostimulation in the treatment of psychiatric disorders: Underlying mechanisms and critical analysis of circuit-based interventions
    F R Bambico, A Nicoglou, J Relente +2
    Molecular PsychiatryPeer-reviewedCC BY-NC-ND 4.0Full textNeurosciencePsychiatry & mental healthHAL
  3. NeuroTest: a benchtop testbed for evaluating sensing-capable electrophysiology and neurostimulation systems
    Morrow JK, H Cho, M Benjaber +3
    Journal of Neural EngineeringPeer-reviewedCC BY 4.0Full text1 citedNeurosciencePMC
  4. Feasibility of an anterior abdominal electrode array for non-invasive measurement of uterine contractions across the menstrual cycle
    S. Shen, Z. Bao, T. Coleman
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  5. A multi-electrode array and immunofluorescence workflow to characterize impacts of HHV-6 infection in induced pluripotent stems cells differentiated to mixed neuronal endpoints
    E. Bahramian, X. Yang, A. Bajpai +2
    bioRxivPreprintAll rights reservedFull textMicrobiologybioRxiv
BibTeX
@article{mancabelli2026computational,
  title = {{Computational analysis of a high-density electrode to scale the electric field geometry and intensity for neurostimulation.}},
  author = {Kegan Mancabelli and Albert H Titus and Filip Stefanovic},
  journal = {Biomedical engineering online},
  year = {2026},
  month = aug,
  doi = {10.1186/s12938-026-01610-w},
  url = {https://europepmc.org/article/MED/42958358},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Computational analysis of a high-density electrode to scale the electric field geometry and intensity for neurostimulation.
AU  - Kegan Mancabelli
AU  - Albert H Titus
AU  - Filip Stefanovic
PY  - 2026
DA  - 2026/08/02
JO  - Biomedical engineering online
DO  - 10.1186/s12938-026-01610-w
UR  - https://europepmc.org/article/MED/42958358
AB  - High-density grid electrodes can be configured to spatially scale the neurostimulation fields and enable the control of depth, intensity, and stimulation vectoring. In this study, we computationally analyze a high-density cluster electrode (HDCE) technology to measure its scalability and its effects on human tissue. The models are developed in Ansys using the Maxwell 3D Design modeler. More than 24 HDCE electrode configurations were analyzed and compared to standard 8 mm Ag/AgCl electrodes. It was found that the HDCE electrode configurations can be selected to emulate the electric field properties to within 1% of a standard 8 mm Ag/AgCl electrode. Moreover, increasing the number of active electrode contacts in the HDCE non-linearly increases tissue voltage and field intensity at various tissue depths. Specifically, it was found that the sensitivity of tissue voltage and field intensity decreases with the number of active HDCE electrode contacts. Similarly, the different spatial configurations of the HDCE can change the field shape by up to 54%, while the field intensity can be scaled by up to 186%. Similarly, the vector of the stimulation field (i.e., stimulation vector) through the tissues can be adjusted by shifting active electrode positions. When comparing these electrodes to standard 8 mm Ag/AgCl electrodes the results suggest a transformative impact of these technologies to optimize neurostimulation applications. The work presented here is part of a larger project aiming to develop next-generation scalable neurostimulation system that improve rehabilitation outcomes, and provide new adaptive solutions for personalized healthcare.
SN  - 1475-925X
ER  -