Vitamin B12 and one-carbon biomarker assay interference: a systematic review, with a consensus-derived diagnostic algorithm proposed for Gulf primary care
Abstract
IntroductionVitamin B12, holotranscobalamin, and folate are measured almost entirely by immunoassay, a technique susceptible to analytical and pre-analytical interference, while methylmalonic acid and homocysteine are measured by heterogeneous methods, including mass spectrometry. In the Gulf Cooperation Council, where measured deficiency is high, concentrated in metformin-treated type 2 diabetes, and investigated on immunoassay-dominated platforms with limited access to confirmatory functional markers, that susceptibility carries particular clinical weight.MethodsThis systematic review, reported in accordance with PRISMA 2020 and the Synthesis Without Meta-analysis guideline and registered retrospectively, searched four bibliographic databases last run on 24 March 2026.ResultsTwenty-four eligible studies yielded 73 discrete interference observations: nine case reports or series, six observational studies, five method comparisons, and four in vitro interference studies. The largest effects were based on single or non-independent studies. Findings were grouped into four categories that differ in the corrective action they imply: direct immunoassay interference, platform and method bias, pre-analytical effects, and biological confounding. Macrocobalamin was the most frequently reported mechanism, falsely raising both total B12 and holotranscobalamin; thus, the marker used to adjudicate an implausible result is displaced by the same interferent. The two polyethylene glycol criteria disagreed, and neither cross-platform measurement nor serial dilution reliably excluded it. Biotin produced analyte-specific errors on a streptavidin–biotin platform, falsely raising total B12 at low concentrations while falsely lowering folate by up to 25.9%, and susceptibility tracked capture chemistry rather than assay format. Antibody interference moved results in both directions, and a transcobalamin gene variant lowered holotranscobalamin approximately tenfold, the largest error identified. Haemolysis, icterus, and lipaemia lowered homocysteine at interferent concentrations below those at which no interference is claimed; therefore, the functional marker safety net failed in the same direction as the error it exists to detect. Evidence of direct interference was strong for total B12, moderate-to-strong for holotranscobalamin, moderate for folate and homocysteine, and absent for methylmalonic acid.DiscussionThe clinically consequential error is the falsely reassuring result that conceals a treatable deficiency. A pre-analytically aware diagnostic pathway is proposed for Gulf primary care; it is an unvalidated synthesis-and-consensus construction and requires prospective evaluation.Systematic Review RegistrationOpen Science Framework Registries, doi 10.17605/OSF.IO/9FCBQ, identifier 10.17605/OSF.IO/9FCBQ (Open Science Framework Registries; registered retrospectively, as declared in the Methods).
Related
- Integrated bulk and single-cell transcriptomic analyses with experimental validation identify PLOD1 as a diagnostic biomarker and TGF-β1-responsive profibrotic mediator in dupuytren’s disease
- Beyond Mesothelioma: From Diagnostic Biomarker to Therapeutic Opportunity—The Emerging Role of MTAP in Cancer
- Multi-Omics Integration Identifies G6PD as a Candidate Diagnostic and Prognostic Biomarker for Hepatocellular Carcinoma and Suggests Its Immunoregulatory Role
- Folate Receptor Alpha (FRα/FOLR1) in Cancer: Diagnostic, Prognostic or Predictive Biomarker? A Critical Review of Its Clinical Utility
- Biomarker screening and diagnostic model construction for radiation-induced heart disease based on metabolomics.
BibTeX
@article{alkaabi2026vitamin,
title = {{Vitamin B12 and one-carbon biomarker assay interference: a systematic review, with a consensus-derived diagnostic algorithm proposed for Gulf primary care}},
author = {A. Alkaabi and C. Sharma and A. Agha},
journal = {Frontiers in Molecular Biosciences},
year = {2026},
month = nov,
doi = {10.3389/fmolb.2026.1948862},
url = {https://www.frontiersin.org/articles/10.3389/fmolb.2026.1948862},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Vitamin B12 and one-carbon biomarker assay interference: a systematic review, with a consensus-derived diagnostic algorithm proposed for Gulf primary care
AU - A. Alkaabi
AU - C. Sharma
AU - A. Agha
PY - 2026
DA - 2026/11/26
JO - Frontiers in Molecular Biosciences
DO - 10.3389/fmolb.2026.1948862
UR - https://www.frontiersin.org/articles/10.3389/fmolb.2026.1948862
AB - IntroductionVitamin B12, holotranscobalamin, and folate are measured almost entirely by immunoassay, a technique susceptible to analytical and pre-analytical interference, while methylmalonic acid and homocysteine are measured by heterogeneous methods, including mass spectrometry. In the Gulf Cooperation Council, where measured deficiency is high, concentrated in metformin-treated type 2 diabetes, and investigated on immunoassay-dominated platforms with limited access to confirmatory functional markers, that susceptibility carries particular clinical weight.MethodsThis systematic review, reported in accordance with PRISMA 2020 and the Synthesis Without Meta-analysis guideline and registered retrospectively, searched four bibliographic databases last run on 24 March 2026.ResultsTwenty-four eligible studies yielded 73 discrete interference observations: nine case reports or series, six observational studies, five method comparisons, and four in vitro interference studies. The largest effects were based on single or non-independent studies. Findings were grouped into four categories that differ in the corrective action they imply: direct immunoassay interference, platform and method bias, pre-analytical effects, and biological confounding. Macrocobalamin was the most frequently reported mechanism, falsely raising both total B12 and holotranscobalamin; thus, the marker used to adjudicate an implausible result is displaced by the same interferent. The two polyethylene glycol criteria disagreed, and neither cross-platform measurement nor serial dilution reliably excluded it. Biotin produced analyte-specific errors on a streptavidin–biotin platform, falsely raising total B12 at low concentrations while falsely lowering folate by up to 25.9%, and susceptibility tracked capture chemistry rather than assay format. Antibody interference moved results in both directions, and a transcobalamin gene variant lowered holotranscobalamin approximately tenfold, the largest error identified. Haemolysis, icterus, and lipaemia lowered homocysteine at interferent concentrations below those at which no interference is claimed; therefore, the functional marker safety net failed in the same direction as the error it exists to detect. Evidence of direct interference was strong for total B12, moderate-to-strong for holotranscobalamin, moderate for folate and homocysteine, and absent for methylmalonic acid.DiscussionThe clinically consequential error is the falsely reassuring result that conceals a treatable deficiency. A pre-analytically aware diagnostic pathway is proposed for Gulf primary care; it is an unvalidated synthesis-and-consensus construction and requires prospective evaluation.Systematic Review RegistrationOpen Science Framework Registries, doi 10.17605/OSF.IO/9FCBQ, identifier 10.17605/OSF.IO/9FCBQ (Open Science Framework Registries; registered retrospectively, as declared in the Methods).
SN - 2296-889X
ER -