Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 36 min ago
Peer-reviewedCC BY 4.0Renal Failure

Chairside frailty screening in hemodialysis patients: diagnostic accuracy of the Kihon Checklist combined with calf circumference

6 affiliations
  1. 1Department of Electrical Engineering, National Central University, Taoyuan, Taiwan
  2. 2Department of Cardiovascular Surgery, China Medical University Hospital, Taichung, Taiwan
  3. 3Nephrology Medicine, China Medical University Hospital, Taichung, Taiwan
  4. 4School of Medicine, China Medical University, Taichung, Taiwan
  5. 5School of Nursing, China Medical University, Taichung, Taiwan
  6. 6Department of Nursing, China Medical University Hospital, Taichung, Taiwan

Abstract

Background: Frailty screening is important in maintenance hemodialysis (MHD), but routine implementation is limited by time, space, and mobility constraints. Self-reported tools such as the Kihon Checklist (KCL) are feasible but may not fully capture physical vulnerability. This study evaluated whether adding calf circumference (CC) to the KCL improves chairside frailty screening performance.

Methods: This cross-sectional diagnostic accuracy study included 200 MHD patients at a tertiary medical center. Frailty was defined using the Physical Frailty Phenotype (PFP). Multivariable models compared a baseline KCL model with the primary KCL + CC model using bilateral mean CC. Prespecified sensitivity analyses examined bilateral maximum CC and a modified PFP reference standard without the weakness criterion. HGS-containing models were additionally evaluated as exploratory analyses. Model performance was assessed using AUC, continuous net reclassification improvement (cNRI), integrated discrimination improvement (IDI), decision curve analysis, and bootstrap internal validation.

Results: Overall, 120 patients (60.0%) were frail. The baseline KCL model showed strong discrimination (AUC, 0.923; 95% confidence interval [CI], 0.885–0.961), with 80.0% sensitivity and 91.3% specificity. Adding CC improved discrimination (AUC, 0.953; 95% CI, 0.928–0.979), sensitivity (86.7%), reclassification (cNRI, 0.850; IDI, 0.085; both p < 0.001), and net benefit while maintaining specificity (91.3%). Findings remained robust in sensitivity analyses using bilateral maximum CC and a modified PFP without the weakness criterion. The internally validated AUC of the KCL + CC model was 0.942.

Conclusions: Adding CC to the KCL provides a feasible, non-ambulatory chairside approach for improving frailty screening in MHD patients.

Related

  1. Diagnostic Accuracy of Mid-Upper Arm Circumference for Screening Maternal Malnutrition: A Community-based Cross-sectional Study from Eastern India
    S. S. Hembrom, K. A. Kiran, M. Kujur +3
    medRxivPreprintCC BYFull textObstetrics, gynaecology & paediatricsmedRxiv
  2. Effect of eligibility for referral following mass screening for severe acute malnutrition using mid-upper arm circumference: A prospective regression discontinuity design
    Huiyu Hu, Mamadou Ouattara, Mamadou Bountogo +10
    PLOS OnePeer-reviewedCC BY 4.0Full textNutritionPLOS
  3. Cross-cultural validity of the Pediatric Symptom Checklist – Youth Report (PSC-Y) in five ​Global ​South countries: Implications for equitable child mental health screening
    Florian Scharpf, Milena Sievert, Katharina Mattonet +9
    BMC MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefPMC
  4. Metabolic characteristics and diagnostic biomarkers of malnutrition in maintenance hemodialysis patients based on WGCNA analysis
    Bin Shi, Xuyan Wang, Jingya Zhang +6
    Frontiers in PhysiologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Latent tuberculosis infection among hemodialysis patients in a national multi-governorate screening initiative in Egypt
    Wagdy Amin, Rasha Ashmawy, Mahmoud A. Hassan +4
    Scientific ReportsPeer-reviewedCC BY 4.0Full textInfectious diseaseCrossrefDOAJ
BibTeX
@article{wu2026chairside,
  title = {{Chairside frailty screening in hemodialysis patients: diagnostic accuracy of the Kihon Checklist combined with calf circumference}},
  author = {Ching-Feng Wu and Huey-Liang Kuo and Chih-Jung Wu and Ya-Fang Ho and Po-Lei Lee},
  journal = {Renal Failure},
  year = {2026},
  month = nov,
  doi = {10.1080/0886022x.2026.2751274},
  url = {https://doi.org/10.1080/0886022x.2026.2751274},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Chairside frailty screening in hemodialysis patients: diagnostic accuracy of the Kihon Checklist combined with calf circumference
AU  - Ching-Feng Wu
AU  - Huey-Liang Kuo
AU  - Chih-Jung Wu
AU  - Ya-Fang Ho
AU  - Po-Lei Lee
PY  - 2026
DA  - 2026/11/09
JO  - Renal Failure
DO  - 10.1080/0886022x.2026.2751274
UR  - https://doi.org/10.1080/0886022x.2026.2751274
AB  - Background: Frailty screening is important in maintenance hemodialysis (MHD), but routine implementation is limited by time, space, and mobility constraints. Self-reported tools such as the Kihon Checklist (KCL) are feasible but may not fully capture physical vulnerability. This study evaluated whether adding calf circumference (CC) to the KCL improves chairside frailty screening performance.  Methods: This cross-sectional diagnostic accuracy study included 200 MHD patients at a tertiary medical center. Frailty was defined using the Physical Frailty Phenotype (PFP). Multivariable models compared a baseline KCL model with the primary KCL + CC model using bilateral mean CC. Prespecified sensitivity analyses examined bilateral maximum CC and a modified PFP reference standard without the weakness criterion. HGS-containing models were additionally evaluated as exploratory analyses. Model performance was assessed using AUC, continuous net reclassification improvement (cNRI), integrated discrimination improvement (IDI), decision curve analysis, and bootstrap internal validation.  Results: Overall, 120 patients (60.0%) were frail. The baseline KCL model showed strong discrimination (AUC, 0.923; 95% confidence interval [CI], 0.885–0.961), with 80.0% sensitivity and 91.3% specificity. Adding CC improved discrimination (AUC, 0.953; 95% CI, 0.928–0.979), sensitivity (86.7%), reclassification (cNRI, 0.850; IDI, 0.085; both p < 0.001), and net benefit while maintaining specificity (91.3%). Findings remained robust in sensitivity analyses using bilateral maximum CC and a modified PFP without the weakness criterion. The internally validated AUC of the KCL + CC model was 0.942.  Conclusions: Adding CC to the KCL provides a feasible, non-ambulatory chairside approach for improving frailty screening in MHD patients.
SN  - 0886-022X
SN  - 1525-6049
ER  -