Bessel-Gauss laser beam reshaping for high-precision surgical incisions
- 1Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, UK.
- 2Leeds Institute for Medical Research, University of Leeds, Leeds, West Yorkshire, LS2 9JT, UK.
Abstract
Lasers are widely used in clinical environments and are essential tools for high-precision tissue ablation and surgical incisions. Achieving the required laser intensity typically involves focusing a Gaussian beam. However, the intrinsic coupling between focal depth and spot size means small incisions require extremely accurate standoff positioning. Bessel-Gauss beams offer an alternative by decoupling these parameters, but to the detriment of varying intensity along the propagation axis. Here, a beam shaping approach is presented that integrates custom optics with an axicon to generate a modified Bessel-Gauss beam, using a 1030 nm, 6 ps laser. The resultant beam exhibits a near-constant intensity over a fixed axial range. Microscale incisions in lamb liver tissue were performed, demonstrating feasibility for surgical applications with a tenfold improvement in depth of focus compared to a Gaussian beam of similar spot size. This low-cost, passive beam shaping technique offers significant potential for enhancing precision and consistency in surgical procedures.
Related
- Nonlinear Reshaping of Gaussian Water Wave Packets
- Pulse-by-pulse imaging of reversible, collective reshaping in laser-excited gold nanorods
- Polarization-controlled orbital force in optical traps of vector Bessel beams
- Propagation of partially coherent radially polarized Bessel-Gaussian beams carrying asymmetric power-exponent-phase vortices through atmospheric turbulence
- Rapid fabrication of height-tunable high-aspect-ratio voxels by tailored Bessel beams
BibTeX
@article{brown2026besselgauss,
title = {{Bessel-Gauss laser beam reshaping for high-precision surgical incisions}},
author = {Calum M Brown and Jakob A Gueye and Enrique Calisto and Tatiana Malikova and David G Jayne and Jonathan D Shephard and Duncan P Hand and Richard M Carter},
journal = {Biomedical optics express},
year = {2026},
month = oct,
doi = {10.1364/boe.611561},
url = {https://europepmc.org/article/PMC/PMC13795939},
note = {CC BY},
}
RIS
TY - JOUR
TI - Bessel-Gauss laser beam reshaping for high-precision surgical incisions
AU - Calum M Brown
AU - Jakob A Gueye
AU - Enrique Calisto
AU - Tatiana Malikova
AU - David G Jayne
AU - Jonathan D Shephard
AU - Duncan P Hand
AU - Richard M Carter
PY - 2026
DA - 2026/10/13
JO - Biomedical optics express
DO - 10.1364/boe.611561
UR - https://europepmc.org/article/PMC/PMC13795939
AB - Lasers are widely used in clinical environments and are essential tools for high-precision tissue ablation and surgical incisions. Achieving the required laser intensity typically involves focusing a Gaussian beam. However, the intrinsic coupling between focal depth and spot size means small incisions require extremely accurate standoff positioning. Bessel-Gauss beams offer an alternative by decoupling these parameters, but to the detriment of varying intensity along the propagation axis. Here, a beam shaping approach is presented that integrates custom optics with an axicon to generate a modified Bessel-Gauss beam, using a 1030 nm, 6 ps laser. The resultant beam exhibits a near-constant intensity over a fixed axial range. Microscale incisions in lamb liver tissue were performed, demonstrating feasibility for surgical applications with a tenfold improvement in depth of focus compared to a Gaussian beam of similar spot size. This low-cost, passive beam shaping technique offers significant potential for enhancing precision and consistency in surgical procedures.