Electrochemical Quantification of Salivary Amyloid-β1–42 Using Disposable Gold Screen-Printed Electrodes: Analytical Validation and Comparison with ELISA
4 affiliations
- 1Kasetsart University , , ,
- 2Vajira Hospital, Navamindradhiraj University , , ,
- 3Srinakharinwirot University , , , ,
- 4Srinakharinwirot University , , ,
Abstract
Sensitive quantification of low-abundance biomarkers in noninvasive biofluids is critical for advancing Alzheimer’s disease (AD) diagnostics. In this study, we developed an electrochemical immunosensor for the detection of amyloid β 1–42 (Aβ1–42) in human saliva using disposable gold screen-printed electrodes (AuSPEs). The sensing interface was fabricated through covalent antibody immobilization on a cysteamine-modified gold surface to enable selective electrochemical recognition of Aβ1–42. Under optimized conditions, the immunosensor exhibited a linear response over the concentration range of 10–40 pg/mL with a limit of detection of 5.39 pg/mL and good selectivity toward structurally related peptides. To reduce matrix-associated signal variability during saliva analysis, a simple PBS dilution protocol was applied, resulting in reduced intersubject signal variability compared with untreated saliva samples (SD ≤ 3.05 μA) and a strong correlation with PBS measurements (R2 = 0.9962). The developed platform demonstrated the feasibility of electrochemical detection of low-abundance Aβ1–42 in diluted human saliva using disposable electrodes. Furthermore, pilot application using 25 human saliva specimens demonstrated strong linear concordance with a commercial ELISA benchmark (R2 = 0.9817), supporting the analytical reliability and preliminary feasibility of this noninvasive platform for salivary Aβ1–42 measurement.
Related
- Analytical Method Development and Validation for the Quantification of Related Substances in Pantoprazole Gastro-Resistant Tablets by RP-HPLC: A Critical Review
- Insights into the electrochemical behaviour of brominated RNA nucleobases at microband screen-printed graphite electrodes
- Defocusing-Controlled Morphology and Electrochemical Performance of Laser-Induced Graphene Electrodes for Microsupercapacitors
- From hard carbon to activated carbon: influence of surface area and pore structure on the electrochemical performance of coconut rachis-derived supercapacitor electrodes
- A coupled experimental-modeling framework for evaluating the electrochemical performance of lithium-ion battery electrodes remanufactured with recycled LiFePO ₄
BibTeX
@article{vutipow2026electrochemical,
title = {{Electrochemical Quantification of Salivary Amyloid-β1–42 Using Disposable Gold Screen-Printed Electrodes: Analytical Validation and Comparison with ELISA}},
author = {Nakarin Vutipow and Jutturong Ckumdee and Somchai Santiwatanakul and Atip Krittayasingh and Thongchai Kaewphinit},
journal = {ACS Omega},
year = {2026},
month = nov,
doi = {10.1021/acsomega.6c10273},
url = {https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c10273/5472106/Electrochemical-Quantification-of-Salivary-Amyloid},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Electrochemical Quantification of Salivary Amyloid-β1–42 Using Disposable Gold Screen-Printed Electrodes: Analytical Validation and Comparison with ELISA
AU - Nakarin Vutipow
AU - Jutturong Ckumdee
AU - Somchai Santiwatanakul
AU - Atip Krittayasingh
AU - Thongchai Kaewphinit
PY - 2026
DA - 2026/11/18
JO - ACS Omega
DO - 10.1021/acsomega.6c10273
UR - https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c10273/5472106/Electrochemical-Quantification-of-Salivary-Amyloid
AB - Sensitive quantification of low-abundance biomarkers in noninvasive biofluids is critical for advancing Alzheimer’s disease (AD) diagnostics. In this study, we developed an electrochemical immunosensor for the detection of amyloid β 1–42 (Aβ1–42) in human saliva using disposable gold screen-printed electrodes (AuSPEs). The sensing interface was fabricated through covalent antibody immobilization on a cysteamine-modified gold surface to enable selective electrochemical recognition of Aβ1–42. Under optimized conditions, the immunosensor exhibited a linear response over the concentration range of 10–40 pg/mL with a limit of detection of 5.39 pg/mL and good selectivity toward structurally related peptides. To reduce matrix-associated signal variability during saliva analysis, a simple PBS dilution protocol was applied, resulting in reduced intersubject signal variability compared with untreated saliva samples (SD ≤ 3.05 μA) and a strong correlation with PBS measurements (R2 = 0.9962). The developed platform demonstrated the feasibility of electrochemical detection of low-abundance Aβ1–42 in diluted human saliva using disposable electrodes. Furthermore, pilot application using 25 human saliva specimens demonstrated strong linear concordance with a commercial ELISA benchmark (R2 = 0.9817), supporting the analytical reliability and preliminary feasibility of this noninvasive platform for salivary Aβ1–42 measurement.
SN - 2470-1343
ER -