Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 31 min ago
PreprintCC BYmedRxiv

The dynamics of arterial pressure itself predict intraoperative hypotension beyond its current value: an interpretable additive model validated in 3,069 external patients under a selection-bias-resistant protocol

  1. 1Hospital Universitario Puerta del Mar, Cadiz, Spain

Abstract

BackgroundWhether predictors of intraoperative hypotension (IOH) add information beyond the mean arterial pressure (MAP) already displayed on the monitor is contested: selection bias in common evaluation designs inflates apparent performance, and the field has called for comparisons against simple MAP-based references under bias-resistant protocols. Existing predictors also depend on proprietary waveform analysis or pulse-contour monitors, restricting both deployment and external validation.

MethodsUsing 807 non-cardiac surgery patients from the open VitalDB database, we derived an additive gradient boosting model (one split per tree: a learned shape function per variable, no interactions) from three variables computable from an arterial line alone: current MAP, its drift from the patients own 20-minute baseline, and the growth of its rolling variance (critical slowing down). Evaluation used patient-level 5-fold cross-validation under a strict protocol - exclusion of the 65-75 mmHg grey zone and of all samples already hypotensive at prediction time - with MAP alone (same learner class) as comparator. The frozen model was then validated, without any refitting, on an independent cohort from another continent (MOVER, University of California Irvine) following a pre-registered plan sealed before external data access.

ResultsIn development the pressure-only model reached AUROC 0.907 vs. 0.884 for MAP alone ({Delta}AUROC +0.023, 95% CI +0.017 to +0.029) at 5 min, with +0.031 and +0.032 at 10 and 15 min, and good calibration (Brier skill +0.418 vs. prevalence). In external validation on 3 069 patients (442 194 samples, 1-minute charting, event prevalence 5.8%), the advantage not only transferred but was larger than in development: AUROC 0.696 vs. 0.638, {Delta}AUROC +0.058 (95% CI +0.051 to +0.064), meeting both pre-registered gates. Discrimination transferred; calibration did not (external Brier skill -0.014), requiring local recalibration. In the unrestricted scenario, where samples already at threshold are retained, the advantage collapsed (+0.007), reproducing the selection effect this paper documents. A secondary model adding pulse-contour cardiac output and stroke volume variation improved development discrimination further ({Delta}AUROC +0.035) but could be externally validated in only 39 patients, because those signals are rarely recorded.

ConclusionsThe dynamics of arterial pressure itself -- drift from a patient-specific baseline and variance growth -- carry predictive information beyond its current value, in a fully interpretable additive model that requires only an arterial line, no waveform access and no proprietary hardware. The advantage is confirmed in a pre-registered frozen-model external validation of over three thousand patients, and is largest at coarse recording cadence, where instantaneous pressure is least informative.

Related

  1. Dynamic machine-learning model for early prediction of intraoperative hypotension using 5-minute perioperative time-series data: a multicenter retrospective study
    Bo Long, Yifeng Ye, Hang Xing +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. The Effects of Intraoperative Hypotension on Postoperative Acute Kidney Injury and Myocardial Injury: A Systematic Review and modelling study
    Jiaxin Zhao, Xuan Li, Yunfei Lv +3
    PhenomicsPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  3. Temporal overlap of intraoperative hypotension and hypocapnia and postoperative outcomes after major open intracranial surgery: a time-weighted dual-hit cohort study
    Xing Yan, Xuemin Zou, Ruowen Yang +2
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Cumulative Intraoperative Hypotension Burden as a Predictor of Early Quality of Recovery Following General Anesthesia: A Prospective Observational Study
    Velimala Swaroopa, Bingi Swathi
    Journal of Medicine, Pharmacology and Medical Devises TechnologyPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJDOAJ
  5. Intraoperative hypotension and postoperative acute kidney injury or myocardial injury after liver resection: A protocol for a systematic review and meta-analysis
    Yi Duan, Meng Li, Mengzhuo Guo +2
    PLOS OnePeer-reviewedCC BY 4.0Full textEpidemiology & public healthPhysiologyPLOS
BibTeX
@misc{oyarzun2026dynamics,
  title = {{The dynamics of arterial pressure itself predict intraoperative hypotension beyond its current value: an interpretable additive model validated in 3,069 external patients under a selection-bias-resistant protocol}},
  author = {R. Oyarzun and P. Hernandez},
  howpublished = {medRxiv},
  year = {2026},
  month = aug,
  doi = {10.64898/2026.08.26.26361468},
  url = {https://www.medrxiv.org/content/10.64898/2026.08.26.26361468v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - The dynamics of arterial pressure itself predict intraoperative hypotension beyond its current value: an interpretable additive model validated in 3,069 external patients under a selection-bias-resistant protocol
AU  - R. Oyarzun
AU  - P. Hernandez
PY  - 2026
DA  - 2026/08/26
PB  - medRxiv
DO  - 10.64898/2026.08.26.26361468
UR  - https://www.medrxiv.org/content/10.64898/2026.08.26.26361468v1
AB  - BackgroundWhether predictors of intraoperative hypotension (IOH) add information beyond the mean arterial pressure (MAP) already displayed on the monitor is contested: selection bias in common evaluation designs inflates apparent performance, and the field has called for comparisons against simple MAP-based references under bias-resistant protocols. Existing predictors also depend on proprietary waveform analysis or pulse-contour monitors, restricting both deployment and external validation.  MethodsUsing 807 non-cardiac surgery patients from the open VitalDB database, we derived an additive gradient boosting model (one split per tree: a learned shape function per variable, no interactions) from three variables computable from an arterial line alone: current MAP, its drift from the patients own 20-minute baseline, and the growth of its rolling variance (critical slowing down). Evaluation used patient-level 5-fold cross-validation under a strict protocol - exclusion of the 65-75 mmHg grey zone and of all samples already hypotensive at prediction time - with MAP alone (same learner class) as comparator. The frozen model was then validated, without any refitting, on an independent cohort from another continent (MOVER, University of California Irvine) following a pre-registered plan sealed before external data access.  ResultsIn development the pressure-only model reached AUROC 0.907 vs. 0.884 for MAP alone ({Delta}AUROC +0.023, 95% CI +0.017 to +0.029) at 5 min, with +0.031 and +0.032 at 10 and 15 min, and good calibration (Brier skill +0.418 vs. prevalence). In external validation on 3 069 patients (442 194 samples, 1-minute charting, event prevalence 5.8%), the advantage not only transferred but was larger than in development: AUROC 0.696 vs. 0.638, {Delta}AUROC +0.058 (95% CI +0.051 to +0.064), meeting both pre-registered gates. Discrimination transferred; calibration did not (external Brier skill -0.014), requiring local recalibration. In the unrestricted scenario, where samples already at threshold are retained, the advantage collapsed (+0.007), reproducing the selection effect this paper documents. A secondary model adding pulse-contour cardiac output and stroke volume variation improved development discrimination further ({Delta}AUROC +0.035) but could be externally validated in only 39 patients, because those signals are rarely recorded.  ConclusionsThe dynamics of arterial pressure itself -- drift from a patient-specific baseline and variance growth -- carry predictive information beyond its current value, in a fully interpretable additive model that requires only an arterial line, no waveform access and no proprietary hardware. The advantage is confirmed in a pre-registered frozen-model external validation of over three thousand patients, and is largest at coarse recording cadence, where instantaneous pressure is least informative.
ER  -