Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BY-NC-NDJournal of nanobiotechnology

Toward closed-loop engineering of nanomedicines: integrating AI-enabled design, microfluidic manufacturing, and organ-on-a-chip validation.

6 affiliations
  1. 1College of Pharmacy, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, 550025, China.
  2. 2Department of Biomedical Sciences, Faculty of Medicine, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macau, China.
  3. 3College of Traditional Chinese Medicine, Guangdong Pharmaceutical University, Guangzhou, 510006, Guangdong, China.
  4. 4College of Life Sciences and Biopharmaceuticals, Guangdong Pharmaceutical University, Guangzhou, 510006, Guangdong, China. [email protected].
  5. 5College of Pharmacy, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, 550025, China. [email protected].
  6. 6College of Pharmacy, Guangdong Medical University, Dongguan, 523808, Guangdong, China. [email protected].

Abstract

Nanomedicine development is constrained less by a shortage of candidate materials than by weak coupling among formulation design, reproducible manufacturing, and biologically informative validation. This review examines how artificial intelligence (AI)-enabled design, microfluidic manufacturing, and tiered biological testing can be integrated into a design-manufacture-test-learn (DMTL) framework. We focus on the interfaces linking design descriptors and critical material attributes to critical process parameters, distribution-resolved and longitudinal critical quality attributes (CQAs), biological dose metrics, functional endpoints, and model updates. Particular attention is given to feasibility-constrained inverse design; nanoparticle heterogeneity at the single-particle and subpopulation levels; time-dependent channel fouling and process drift; cross-platform dose normalization; storage stability and cold-chain resilience; and the fit-for-purpose use of organ-on-a-chip systems. Quantitative benchmarking of representative primary studies indicates that current evidence is strongest at the component and partial-loop levels, with reported advances in model-guided formulation selection, process-CQA prediction, prospective experimental validation, and mechanism-relevant biological testing. However, direct comparisons remain limited by heterogeneity in datasets, validation strategies, manufacturing conditions, assay formats, and biological endpoints. Repeated end-to-end DMTL cycles integrating uncertainty-aware model updating, controlled and traceable manufacturing, mechanism-relevant testing, independent external validation, and prespecified stopping criteria have not yet been demonstrated. To distinguish conceptual integration from measurable closed-loop performance, we propose a five-level maturity model, a minimum reporting set, and a four-domain scoring framework encompassing design intelligence, process intelligence, biological fidelity, and translational readiness. This evidence-calibrated framework delineates the current evidence boundary and provides practical criteria for designing, comparing, and validating future closed-loop nanomedicine platforms.

Related

  1. Engineering Natural Product Nanomedicines to Modulate Tumor Immunometabolism for Enhanced Cancer Immunotherapy
    Yang Xiao, Shaowen Lan, Yuping Dai +5
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  2. Engineering metal-organic frameworks as precision nanomedicines for myocardial infarction therapy.
    Kaijing Liu, Yuguang Liu, Aiai Zhang +1
    Discover nanoPeer-reviewedCC BY-NC-NDFull textInorganic & organometallic chemistryEurope PMC
  3. Numerical and experimental study on the fabrication of core-shell fibers for tissue engineering using a microfluidic-electrospinning coupled method
    Isabela Zarpellon, Stéphane Popinet, Timothée Baudequin +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textMaterials & polymersHAL
  4. Orbital engineering of asymmetric Cu sites in MOFs for fenton reaction towards atomic surface manufacturing
    Chun Cao, Anguo Zhang, Xinyu Li +5
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Inorganic & organometallic chemistryCrossref
  5. Microfluidic engineering of CeO2/Peptide nanosheet-integrated bioactive hydrogel microspheres for multi-enzymatic biomimetic catalytic therapy of osteoarthritis
    Chenxi Du, Guanghui Gu, Xinyue Wang +3
    Journal of NanobiotechnologyPeer-reviewedCC BY-NC-ND 4.0Full textMaterials & polymersPMC
BibTeX
@article{mu2026toward,
  title = {{Toward closed-loop engineering of nanomedicines: integrating AI-enabled design, microfluidic manufacturing, and organ-on-a-chip validation.}},
  author = {Kai-Lang Mu and Rui-Qi Liao and Chang-Mao Guo and Su Chen and Jun-Li Xie and Yu-Chen Liu and Gang Liu and Zhi-Gang Ju and Bing-Nan Liu and Xiao-Min Tang and Yuan Yuan and Yu-Xin Pang},
  journal = {Journal of nanobiotechnology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12951-026-04921-1},
  url = {https://europepmc.org/article/MED/43009972},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Toward closed-loop engineering of nanomedicines: integrating AI-enabled design, microfluidic manufacturing, and organ-on-a-chip validation.
AU  - Kai-Lang Mu
AU  - Rui-Qi Liao
AU  - Chang-Mao Guo
AU  - Su Chen
AU  - Jun-Li Xie
AU  - Yu-Chen Liu
AU  - Gang Liu
AU  - Zhi-Gang Ju
AU  - Bing-Nan Liu
AU  - Xiao-Min Tang
AU  - Yuan Yuan
AU  - Yu-Xin Pang
PY  - 2026
DA  - 2026/08/14
JO  - Journal of nanobiotechnology
DO  - 10.1186/s12951-026-04921-1
UR  - https://europepmc.org/article/MED/43009972
AB  - Nanomedicine development is constrained less by a shortage of candidate materials than by weak coupling among formulation design, reproducible manufacturing, and biologically informative validation. This review examines how artificial intelligence (AI)-enabled design, microfluidic manufacturing, and tiered biological testing can be integrated into a design-manufacture-test-learn (DMTL) framework. We focus on the interfaces linking design descriptors and critical material attributes to critical process parameters, distribution-resolved and longitudinal critical quality attributes (CQAs), biological dose metrics, functional endpoints, and model updates. Particular attention is given to feasibility-constrained inverse design; nanoparticle heterogeneity at the single-particle and subpopulation levels; time-dependent channel fouling and process drift; cross-platform dose normalization; storage stability and cold-chain resilience; and the fit-for-purpose use of organ-on-a-chip systems. Quantitative benchmarking of representative primary studies indicates that current evidence is strongest at the component and partial-loop levels, with reported advances in model-guided formulation selection, process-CQA prediction, prospective experimental validation, and mechanism-relevant biological testing. However, direct comparisons remain limited by heterogeneity in datasets, validation strategies, manufacturing conditions, assay formats, and biological endpoints. Repeated end-to-end DMTL cycles integrating uncertainty-aware model updating, controlled and traceable manufacturing, mechanism-relevant testing, independent external validation, and prespecified stopping criteria have not yet been demonstrated. To distinguish conceptual integration from measurable closed-loop performance, we propose a five-level maturity model, a minimum reporting set, and a four-domain scoring framework encompassing design intelligence, process intelligence, biological fidelity, and translational readiness. This evidence-calibrated framework delineates the current evidence boundary and provides practical criteria for designing, comparing, and validating future closed-loop nanomedicine platforms.
SN  - 1477-3155
ER  -