A novel needle insertion technique for electromyography targeting the flexor digitorum profundus (Digits 2 and 3) : A cadaveric validation study
4 affiliations
- 1Department of Physical Medicine and Rehabilitation, College of Medicine, Korea University, Ansan, Republic of Korea
- 2Department of Internal Medicine, Division of Oncology/Hematology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, Republic of Korea
- 3Department of Anatomy, Korea University College of Medicine, Seoul, Republic of Korea
- 4Division of Brain Korea 21 Plus Program for Biomedical Science, Korea University College of Medicine, Seoul, Republic of Korea.
Abstract
The flexor digitorum profundus (FDP) muscle plays a crucial role in finger flexion and is innervated by the anterior interosseous and ulnar nerves. Electromyographic evaluation of the FDP is essential in diagnosing neuromuscular disorders but carries a risk of neurovascular injury due to the complexity of accurate needle placement. This study aimed to evaluate the anatomical feasibility of a landmark-based needle insertion technique for the index- and middle-finger portions of the FDP in fresh cadaveric specimens by assessing targeting accuracy and the distances from the insertion point to the median nerve and ulnar artery. A cadaveric study was conducted using 21 upper limbs from 11 specimens. Needles were inserted into FDP 1 (digit 2) and FDP 2 (digit 3), using the palmaris longus tendon as a key anatomical landmark. India ink injections were performed at the needle tip to verify correct placement relative to neurovascular structures. The accuracy of placement, distances from the median nerve and ulnar artery, and muscle widths were measured. Anatomical targeting was successful for FDP 1 (digit 2) in 19 of 21 limbs (90.5%) and for FDP 2 (digit 3) in 17 of 21 limbs (81%). The median horizontal distances from the needle insertion point to the median nerve and ulnar artery were 7.0 mm and 9.5 mm, respectively, providing anatomical reference data for needle placement. The median muscle widths were 8.8 mm for FDP 1 and 9.4 mm for FDP 2. These findings support the feasibility of landmark-based needle placement in the FDP, with a high anatomical targeting rate for FDP 1. This anatomical landmark-based technique may provide a useful option for electromyographic evaluation of the FDP, particularly FDP 1, when real-time imaging is unavailable. However, FDP 2 showed lower targeting accuracy. Further clinical studies are needed to evaluate the safety and practicality of this technique in patients.
Related
- The “Minimizing Excessive Rotational Instability Technique” (MERI Technique): A Simple Lateral Tenodesis Reconstructing the Condylar Strap, the Distal Kaplan Fibers, and the Femoral Insertion of the Anterolateral Ligament to Control Internal Rotation During Anterior Cruciate Ligament Surgery
- Anterior Cruciate Ligament Reconstruction With Preservation of the Tibial Insertion of the Hamstring Tendons and Double‐Pulley Technique
- The inwardly pointing knee angle: A novel computed tomography‐based measurement technique and validation study
- Targeting cardiovascular immunometabolism with phytomedicines: an emerging therapeutic technique
- Isolated Medial Ankle Tenosynovitis of the Flexor Digitorum and Posterior Tibialis Tendons: A Case Report of the Role of Early Musculoskeletal Ultrasound in Identifying Anti-citrullinated Protein Antibody (ACPA)-Positive At-Risk Rheumatoid Arthritis
BibTeX
@article{park2026novel,
title = {{A novel needle insertion technique for electromyography targeting the flexor digitorum profundus (Digits 2 and 3) : A cadaveric validation study}},
author = {Hong Bum Park and Se Ryeon Lee and Jun Yeon Lee and Dasom Kim and Im Joo Rhyu and Dong Hwee Kim},
journal = {Medicine},
year = {2026},
month = oct,
doi = {10.1097/md.0000000000051278},
url = {https://europepmc.org/article/PMC/PMC13727252},
note = {CC BY},
}
RIS
TY - JOUR
TI - A novel needle insertion technique for electromyography targeting the flexor digitorum profundus (Digits 2 and 3) : A cadaveric validation study
AU - Hong Bum Park
AU - Se Ryeon Lee
AU - Jun Yeon Lee
AU - Dasom Kim
AU - Im Joo Rhyu
AU - Dong Hwee Kim
PY - 2026
DA - 2026/10/30
JO - Medicine
DO - 10.1097/md.0000000000051278
UR - https://europepmc.org/article/PMC/PMC13727252
AB - The flexor digitorum profundus (FDP) muscle plays a crucial role in finger flexion and is innervated by the anterior interosseous and ulnar nerves. Electromyographic evaluation of the FDP is essential in diagnosing neuromuscular disorders but carries a risk of neurovascular injury due to the complexity of accurate needle placement. This study aimed to evaluate the anatomical feasibility of a landmark-based needle insertion technique for the index- and middle-finger portions of the FDP in fresh cadaveric specimens by assessing targeting accuracy and the distances from the insertion point to the median nerve and ulnar artery. A cadaveric study was conducted using 21 upper limbs from 11 specimens. Needles were inserted into FDP 1 (digit 2) and FDP 2 (digit 3), using the palmaris longus tendon as a key anatomical landmark. India ink injections were performed at the needle tip to verify correct placement relative to neurovascular structures. The accuracy of placement, distances from the median nerve and ulnar artery, and muscle widths were measured. Anatomical targeting was successful for FDP 1 (digit 2) in 19 of 21 limbs (90.5%) and for FDP 2 (digit 3) in 17 of 21 limbs (81%). The median horizontal distances from the needle insertion point to the median nerve and ulnar artery were 7.0 mm and 9.5 mm, respectively, providing anatomical reference data for needle placement. The median muscle widths were 8.8 mm for FDP 1 and 9.4 mm for FDP 2. These findings support the feasibility of landmark-based needle placement in the FDP, with a high anatomical targeting rate for FDP 1. This anatomical landmark-based technique may provide a useful option for electromyographic evaluation of the FDP, particularly FDP 1, when real-time imaging is unavailable. However, FDP 2 showed lower targeting accuracy. Further clinical studies are needed to evaluate the safety and practicality of this technique in patients.
SN - 0304-5412
SN - 1536-5964
SN - 0025-7974
ER -