Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 42 min ago
PreprintCC BY 4.0arXiv

Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy

Abstract

Clutter suppression is a critical preprocessing step in ultrasound blood flow imaging, yet conventional singular value decomposition (SVD) filtering depends on data-specific eigenvalue cutoffs that can remove slow flow along with tissue clutter. Here, we introduce adaptive eigenspectrum remapping (AER), a general framework in which clutter is suppressed by continuously remapping, rather than truncating, the eigenvalue spectrum of the spatiotemporal covariance, and we investigate zero-phase component analysis (ZCA) matrix whitening as an instance of AER for transcranial ultrasound localization microscopy (ULM). Rather than discarding eigenspaces, ZCA-based AER whitens the eigenvalue spectrum, reducing the dominance of coherent clutter, including skull reverberation, while retaining weak flow signals. We evaluate AER on both temporal and spatial covariance matrices in mouse brain datasets acquired with long temporal ensembles. Compared with SVD filtering, ZCA improves microbubble contrast and vascular image quality, increases trajectory density across low- and high-concentration regimes, and reveals more low-velocity trajectories in ULM velocity maps. Spatial AER further maintains reconstruction quality across extended ensembles and enables fuller single capillary reporter (SCaRe) reconstructions, including connected artery-to-capillary-to-vein tracks. These results support AER, here instantiated as ZCA whitening, as a data-adaptive alternative to manually thresholded SVD filtering for high-resolution microvascular imaging.

Related

  1. MRI-Free CT-to-Ultrasound Skull Registration in Transcranial Focused Ultrasound using CMUT based Integrated Therapeutic and Imaging Arrays
    Reza Pakdaman Zangabad, Sai Vikas Satyanarayana, Costas D. Arvanitis +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsarXiv
  2. Self-adaptive transcranial ultrasound imaging using an effective skull model: experimental evaluation on a human skull at 3.15 MHz
    Damien Kuntz, Anthony Novell, Quentin Grimal +2
    Acta AcusticaPeer-reviewedCC BY 4.0Full textBiological & medical physicsHAL
  3. Whole-skull acoustic transparency from a single time-reversal solve for reciprocity-based transducer placement and aperture optimization in transcranial focused ultrasound
    Gianmarco Pinton
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  4. Metalens-transparent ultrasound transducer module for extended depth photoacoustic microscopy
    Krishnendu Samanta, Myunghoo Lee, Shubham Mirg +5
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  5. High resolution 3D localization of ultrasound sparse sources using a SAGE algorithm
    Sophie V. Heymans, François Rottenberg, Tatiana Gelvez-Barrera +2
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
BibTeX
@misc{lee2026spatiotemporal,
  title = {{Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy}},
  author = {Stephen A Lee and Isidora Jelenkovic and Maia V. Kokoeva and Jean Provost},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.23099},
  eprint = {2610.23099},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.23099},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy
AU  - Stephen A Lee
AU  - Isidora Jelenkovic
AU  - Maia V. Kokoeva
AU  - Jean Provost
PY  - 2026
DA  - 2026/10/16
PB  - arXiv
DO  - 10.48550/arxiv.2610.23099
UR  - https://arxiv.org/abs/2610.23099
AB  - Clutter suppression is a critical preprocessing step in ultrasound blood flow imaging, yet conventional singular value decomposition (SVD) filtering depends on data-specific eigenvalue cutoffs that can remove slow flow along with tissue clutter. Here, we introduce adaptive eigenspectrum remapping (AER), a general framework in which clutter is suppressed by continuously remapping, rather than truncating, the eigenvalue spectrum of the spatiotemporal covariance, and we investigate zero-phase component analysis (ZCA) matrix whitening as an instance of AER for transcranial ultrasound localization microscopy (ULM). Rather than discarding eigenspaces, ZCA-based AER whitens the eigenvalue spectrum, reducing the dominance of coherent clutter, including skull reverberation, while retaining weak flow signals. We evaluate AER on both temporal and spatial covariance matrices in mouse brain datasets acquired with long temporal ensembles. Compared with SVD filtering, ZCA improves microbubble contrast and vascular image quality, increases trajectory density across low- and high-concentration regimes, and reveals more low-velocity trajectories in ULM velocity maps. Spatial AER further maintains reconstruction quality across extended ensembles and enables fuller single capillary reporter (SCaRe) reconstructions, including connected artery-to-capillary-to-vein tracks. These results support AER, here instantiated as ZCA whitening, as a data-adaptive alternative to manually thresholded SVD filtering for high-resolution microvascular imaging.
ER  -