Opportunistic CT sarcopenia screening: multicenter validation of sex-specific T12-to-L3 conversion models
5 affiliations
- 1Department of Radiology, Guangzhou Red Cross Hospital (Guangzhou Red Cross Hospital of Jinan University), 396 Tongfu Road, Guangzhou, Guangdong Province 510220 China
- 2Department of Radiology, Wuhan Third Hospital, Tongren Hospital of Wuhan University, 241 Liuyang Road, Wuhan, Hubei Province 430063 China
- 3Department of Radiology, Xinyi People’s Hospital, Yinhu West Road, Xinyi, Guangdong Province 525300 China
- 4Department of Radiology, Guangzhou First People’s Hospital, 1Panfu Road, Guangzhou, Guangdong Province 510180 China
- 5Ultrasound Department, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou, 510120 China
Abstract
Objectives: Measuring muscle parameters at the third lumbar vertebra (L3) is a standard approach for assessing sarcopenia, but these data are not always available on routine CT scans. The twelfth thoracic vertebra (T12) is a promising surrogate, but reliable conversion formulas are lacking. This study aimed to develop and validate formulas for estimating L3 muscle parameters from T12 measurements.
Materials & methods: This retrospective multicenter study included a total of 3,698 patients aged ≥ 60 years, comprising a training cohort (n = 3,073), an internal validation cohort (n = 216), and two external validation cohorts (n = 163 and n = 246). Deep learning software was used to quantify skeletal muscle index (SMI), normal-attenuation SMI (NSMI), skeletal muscle density (SMD), and intramuscular adipose tissue percentage (IMAT%) at the T12 and L3 levels. Agreement was evaluated via Bland-Altman analysis and concordance correlation coefficients (CCCs). Sex-specific basic (T12-only) and advanced (incorporating age, body mass index [BMI], and interaction terms) linear regression models were developed, with regression coefficients strictly stabilized utilizing a 1000-iteration bootstrap resampling method.
Results: Significant systematic biases were observed between T12 and L3 measurements (e.g., male SMI bias: -13 cm²/m²), although agreement remained good to excellent (CCCs: 0.82–0.9). The advanced models, incorporating age and BMI, demonstrated high predictive accuracy (training R2: 0.68–0.83) and consistently outperformed basic models in all validation cohorts (all p < 0.001), with NSMI and SMD showing the highest magnitude of improvement.
Conclusions: We developed reliable, sex-specific conversion formulas to estimate L3 muscle parameters from T12 CT images. These validated tools facilitate opportunistic sarcopenia screening from routine CT scans where the L3 vertebra is unavailable, promoting standardized diagnosis and broader clinical application.
Related
- Federated learning for privacy-preserving opportunistic screening of lumbar-spine DXA-defined osteoporotic-level bone mineral density using chest radiographs: A multi-center independent validation study
- Sarcopenia screening as a gateway to multidomain nutrition and lifestyle strategies in adults: validation of SARC-F and Ishii’s score in a community-based sample from Guayaquil
- Development and validation of a risk stratification model for mild cognitive impairment among older adults with possible sarcopenia integrating traditional Chinese medicine constitution: a multicenter cross-sectional study
- Comparative validation and local adaptation of gastric cancer risk assessment models in a large multicenter endoscopic screening cohort in China.
- Histopathological Spectrum and Yield of Advanced Neoplasia in Opportunistic Colonoscopy Without Organised Screening: A Single-Centre Cross-Sectional Study from Western Romania
BibTeX
@article{xiong2026opportunistic,
title = {{Opportunistic CT sarcopenia screening: multicenter validation of sex-specific T12-to-L3 conversion models}},
author = {Yuchao Xiong and Guoxi Ye and Wei Guo and Li Wu and Yun Wan and Yingying Liang and Bohuan Wang and Zhiqiong Li and Siting Ye and Xuwen Zeng and Fan Xu},
journal = {BMC Geriatrics},
year = {2026},
month = aug,
doi = {10.1186/s12877-026-08136-9},
url = {https://doi.org/10.1186/s12877-026-08136-9},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Opportunistic CT sarcopenia screening: multicenter validation of sex-specific T12-to-L3 conversion models
AU - Yuchao Xiong
AU - Guoxi Ye
AU - Wei Guo
AU - Li Wu
AU - Yun Wan
AU - Yingying Liang
AU - Bohuan Wang
AU - Zhiqiong Li
AU - Siting Ye
AU - Xuwen Zeng
AU - Fan Xu
PY - 2026
DA - 2026/08/28
JO - BMC Geriatrics
DO - 10.1186/s12877-026-08136-9
UR - https://doi.org/10.1186/s12877-026-08136-9
AB - Objectives: Measuring muscle parameters at the third lumbar vertebra (L3) is a standard approach for assessing sarcopenia, but these data are not always available on routine CT scans. The twelfth thoracic vertebra (T12) is a promising surrogate, but reliable conversion formulas are lacking. This study aimed to develop and validate formulas for estimating L3 muscle parameters from T12 measurements. Materials & methods: This retrospective multicenter study included a total of 3,698 patients aged ≥ 60 years, comprising a training cohort (n = 3,073), an internal validation cohort (n = 216), and two external validation cohorts (n = 163 and n = 246). Deep learning software was used to quantify skeletal muscle index (SMI), normal-attenuation SMI (NSMI), skeletal muscle density (SMD), and intramuscular adipose tissue percentage (IMAT%) at the T12 and L3 levels. Agreement was evaluated via Bland-Altman analysis and concordance correlation coefficients (CCCs). Sex-specific basic (T12-only) and advanced (incorporating age, body mass index [BMI], and interaction terms) linear regression models were developed, with regression coefficients strictly stabilized utilizing a 1000-iteration bootstrap resampling method. Results: Significant systematic biases were observed between T12 and L3 measurements (e.g., male SMI bias: -13 cm²/m²), although agreement remained good to excellent (CCCs: 0.82–0.9). The advanced models, incorporating age and BMI, demonstrated high predictive accuracy (training R2: 0.68–0.83) and consistently outperformed basic models in all validation cohorts (all p < 0.001), with NSMI and SMD showing the highest magnitude of improvement. Conclusions: We developed reliable, sex-specific conversion formulas to estimate L3 muscle parameters from T12 CT images. These validated tools facilitate opportunistic sarcopenia screening from routine CT scans where the L3 vertebra is unavailable, promoting standardized diagnosis and broader clinical application.
SN - 1471-2318
ER -