A fiducial-based framework for precise MRI-guided stereotaxic targeting in nonhuman primates

  1. 1National Institutes of Health

Abstract

Background Accurate MRI-guided stereotaxic targeting in nonhuman primates requires reliable registration between MRI coordinates and stereotaxic space. We evaluated skull-fixed MR-compatible screw fiducials as a practical reference for this registration. Results Using a 3D-printed skull model with 28 fiducials and three internal targets, we compared offset translation, rigid registration, and affine registration under aligned and misaligned conditions. Offset translation was most sensitive to misalignment. Affine registration fit skull-surface fiducials closely, but rigid registration produced lower overall target errors. In vivo validation showed that implanted fiducials could be identified on MRI and re-measured during a later surgery. Comparison with existing methods This approach builds on previous fiducial-based stereotaxic methods by systematically comparing registration transforms, testing misalignment, evaluating fiducial number, and measuring accuracy at independent internal targets. Conclusions Skull-fixed fiducials provide a practical framework for MRI-to-stereotaxic registration. Rigid registration may offer the safest balance between correcting positioning differences and preserving accuracy at internal targets.

Related

  1. INS-fMRI: a novel method for mapping mesoscale connectome networks in vivo in nonhuman primates
    X. Du, J. Wang, Y. Zhang +6
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  2. A single-dose recombinant rVSVΔG-CCHFV-GPC vaccine protects nonhuman primates against heterologous Crimean-Congo hemorrhagic fever virus challenge
    R. W. Cross, K. P. Melody, R. L. O'Toole +11
    bioRxivPreprintAll rights reservedFull textMicrobiologybioRxiv
  3. Repeatable, low-drift recordings in behaving nonhuman primates using flexible microelectrodes.
    Daniel P Woods, Grace M Adams, Rana Mozumder +5
    Nature communicationsPeer-reviewedCC BYFull text1 citedNeuroscienceEurope PMC
  4. LAMP2A gene therapy mitigates Parkinson’s disease–related pathology in nonhuman primates
    Marie-Laure Arotcarena, Maria Fouka, Elena G. Gialinaki +22
    Science AdvancesPeer-reviewedCC BY-NCFull textNeuroscienceSci. Adv.CrossrefEurope PMCEurope PMC+1
  5. Nonhuman primates exhibit error type-dependent post-error slowing across modalities
    N. Kaneko, M. Nwokolo, K. Conen +2
    bioRxivPreprintCC BY-NC-NDFull textNeurosciencebioRxiv
BibTeX
@misc{harmon2026fiducialbased,
  title = {{A fiducial-based framework for precise MRI-guided stereotaxic targeting in nonhuman primates}},
  author = {P. Harmon and R. Azadi},
  howpublished = {bioRxiv},
  year = {2026},
  month = aug,
  doi = {10.64898/2026.08.28.747848},
  url = {https://www.biorxiv.org/content/10.64898/2026.08.28.747848v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - A fiducial-based framework for precise MRI-guided stereotaxic targeting in nonhuman primates
AU  - P. Harmon
AU  - R. Azadi
PY  - 2026
DA  - 2026/08/28
PB  - bioRxiv
DO  - 10.64898/2026.08.28.747848
UR  - https://www.biorxiv.org/content/10.64898/2026.08.28.747848v1
AB  - Background Accurate MRI-guided stereotaxic targeting in nonhuman primates requires reliable registration between MRI coordinates and stereotaxic space. We evaluated skull-fixed MR-compatible screw fiducials as a practical reference for this registration. Results Using a 3D-printed skull model with 28 fiducials and three internal targets, we compared offset translation, rigid registration, and affine registration under aligned and misaligned conditions. Offset translation was most sensitive to misalignment. Affine registration fit skull-surface fiducials closely, but rigid registration produced lower overall target errors. In vivo validation showed that implanted fiducials could be identified on MRI and re-measured during a later surgery. Comparison with existing methods This approach builds on previous fiducial-based stereotaxic methods by systematically comparing registration transforms, testing misalignment, evaluating fiducial number, and measuring accuracy at independent internal targets. Conclusions Skull-fixed fiducials provide a practical framework for MRI-to-stereotaxic registration. Rigid registration may offer the safest balance between correcting positioning differences and preserving accuracy at internal targets.