Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti
- 1School of Materials Science & Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea
- 2Industry Support Division, Korea Institute of Ceramic Engineering & Technology, Jinju 52851, Republic of Korea
- 3Advanced Materials Technology Division, Korea Testing & Research Institute, Gwacheon 13810, Republic of Korea
Abstract
Reliable compositional quality control of Ti-doped LiFePO4 (LFP) requires quantitative release of the low-level Ti dopant from a carbon-coated phosphate matrix. We evaluated aqua regia hot-plate digestion and developed a closed-vessel microwave digestion–inductively coupled plasma optical emission spectrometry (ICP-OES) method for Li, Fe, P, and Ti. Aqua regia left a carbon-rich residue containing Ti; mass balance on seven digestions showed that 5.86 ± 0.37% of total Ti was retained, compared with 0.39 ± 0.12%, 0.53 ± 0.11%, and 0.81 ± 0.13% for Li, Fe, and P. The mean Ti recovery across the 14 aqua regia digestions was 92.8% of the assigned value, compared with 100.0% for the microwave procedure. Digestion with 6 mL HNO3 and 2 mL HCl at 240 °C gave quantitative Ti release: between 220 and 240 °C the Ti result rose by 14.0% to a plateau, while Li, Fe, and P changed by less than 2%. Calibration R2 values exceeded 0.999. Recoveries were 98.6–99.8%, repeatability RSDs 0.49–1.51%, and relative expanded uncertainties 0.64–2.20%; the lower calibration limit for Ti was 250 mg kg−1. Method means agreed with values assigned by 14–16 laboratories (compatibility indices ≤ 0.49). Under routine conditions, the method would support Ti specifications of ±13.4% relative or wider.
Related
- PARAFAC-Assisted Excitation–Emission Matrix Fluorescence for Minimal-Preparation Co-Determination of Norfloxacin and Metoclopramide in Human Urine: Overcoming Severe Concentration Imbalance Without Chromatography
- ICRF-assisted Box–Behnken design and optimization for rapid UPLC–PDA determination of dorzolamide hydrochloride and timolol maleate in an ophthalmic preparation
- Digestion and Orthogonal Click Conjugation Enables Nanopore Reading of Proteins
- Machine learning based distribution mapping of gold in soil samples using aqua regia digestion and solid phase extraction
- From Food Structure to L-Cell Exposure: How Processing and Digestion Shape Endogenous GLP-1 Responses
BibTeX
@article{lee2026overcoming,
title = {{Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti}},
author = {Myung-Gyu Lee and Tae-Young Kim and Sam-Hang Yi and Joo-Seok Park and Young-Jun Yoon and Kyoung-Seok Moon},
journal = {Molecules},
year = {2026},
month = oct,
doi = {10.3390/molecules31213915},
url = {https://www.mdpi.com/1420-3049/31/21/3915},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti
AU - Myung-Gyu Lee
AU - Tae-Young Kim
AU - Sam-Hang Yi
AU - Joo-Seok Park
AU - Young-Jun Yoon
AU - Kyoung-Seok Moon
PY - 2026
DA - 2026/10/30
JO - Molecules
DO - 10.3390/molecules31213915
UR - https://www.mdpi.com/1420-3049/31/21/3915
AB - Reliable compositional quality control of Ti-doped LiFePO4 (LFP) requires quantitative release of the low-level Ti dopant from a carbon-coated phosphate matrix. We evaluated aqua regia hot-plate digestion and developed a closed-vessel microwave digestion–inductively coupled plasma optical emission spectrometry (ICP-OES) method for Li, Fe, P, and Ti. Aqua regia left a carbon-rich residue containing Ti; mass balance on seven digestions showed that 5.86 ± 0.37% of total Ti was retained, compared with 0.39 ± 0.12%, 0.53 ± 0.11%, and 0.81 ± 0.13% for Li, Fe, and P. The mean Ti recovery across the 14 aqua regia digestions was 92.8% of the assigned value, compared with 100.0% for the microwave procedure. Digestion with 6 mL HNO3 and 2 mL HCl at 240 °C gave quantitative Ti release: between 220 and 240 °C the Ti result rose by 14.0% to a plateau, while Li, Fe, and P changed by less than 2%. Calibration R2 values exceeded 0.999. Recoveries were 98.6–99.8%, repeatability RSDs 0.49–1.51%, and relative expanded uncertainties 0.64–2.20%; the lower calibration limit for Ti was 250 mg kg−1. Method means agreed with values assigned by 14–16 laboratories (compatibility indices ≤ 0.49). Under routine conditions, the method would support Ti specifications of ±13.4% relative or wider.
SN - 1420-3049
ER -