Effect of graphite powder on the mechanical, durability and electromagnetic shielding performance of cement mortar incorporating ball-milled waste iron mill scale
Abstract
The rapid growth of wireless communication systems, radar technologies, and electronic devices has increased the demand for cementitious materials capable of mitigating electromagnetic interference (EMI) while maintaining adequate structural performance. This study investigates the influence of graphite powder on the mechanical, durability, and electromagnetic shielding performance of cement mortar incorporating a fixed 15% replacement of ball-milled waste iron mill scale. Graphite powder was incorporated at 0–5% by weight of cement. The effects of graphite content on flowability, mechanical properties, durability, electromagnetic shielding effectiveness, and microstructure were systematically evaluated. Compared with the control mix, the incorporation of 2% graphite powder increased the 28-day compressive, flexural, and tensile strengths by approximately 7.2%, 10.6%, and 13.0%, respectively, while simultaneously reducing water absorption, chloride permeability, and sulphate deterioration, indicating improved durability. Electromagnetic shielding effectiveness increased progressively with graphite content, reaching a maximum of 45.4 dB in the X-band frequency range. However, under the fixed 15% ball-milled waste iron mill scale replacement condition, the BW15-G2 mix provided the optimum balance between mechanical performance, durability, and electromagnetic shielding effectiveness, achieving 37.6 dB shielding performance. SEM observations revealed a denser matrix with refined pore structure, while XRD qualitatively indicated enhanced hydration product development in the optimized mix. Response surface methodology demonstrated that curing period predominantly influenced strength development, whereas graphite content governed matrix refinement and overall performance. The developed models and optimum graphite content are applicable only within the investigated fixed 15% ball-milled waste iron mill scale replacement level. The developed multifunctional cement mortar shows promising potential for EMI-sensitive infrastructure, including hospitals, data centres, telecommunication facilities, and defence structures.
Related
- Microstructural and physicochemical characterization, mechanical and durability performance with statistical evaluation of montmorillonite-impregnated burnt red soil bricks incorporating pyrolyzed coffee and tobacco biochars
- Waste-to-resource geopolymer technology: mechanical, durability, and microstructural performance of red Mud–fly ash-stabilized black cotton soil
- Evaluating the multi-scale performance and mechanical behavior of reclaimed asphalt pavement (RAP) mixtures incorporating waste-derived oils and vacuum bottom rejuvenators
- Mechanical and durability performance of metakaolin and fly ash-based geopolymers compared to cement systems
- Effect of Thermoset Matrix Type on the Mechanical, Thermomechanical, and Electromagnetic Performance of Coremat Interlayered Carbon, Glass, and Aramid Fiber-Reinforced Hybrid Sandwich Composites
BibTeX
@article{loganathan2026effect,
title = {{Effect of graphite powder on the mechanical, durability and electromagnetic shielding performance of cement mortar incorporating ball-milled waste iron mill scale}},
author = {G. Loganathan and M. Senthil Pandian and S. Deepa Nivethika},
journal = {Scientific Reports},
year = {2026},
month = oct,
doi = {10.1038/s41598-026-69654-5},
url = {https://www.nature.com/articles/s41598-026-69654-5},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Effect of graphite powder on the mechanical, durability and electromagnetic shielding performance of cement mortar incorporating ball-milled waste iron mill scale
AU - G. Loganathan
AU - M. Senthil Pandian
AU - S. Deepa Nivethika
PY - 2026
DA - 2026/10/05
JO - Scientific Reports
DO - 10.1038/s41598-026-69654-5
UR - https://www.nature.com/articles/s41598-026-69654-5
AB - The rapid growth of wireless communication systems, radar technologies, and electronic devices has increased the demand for cementitious materials capable of mitigating electromagnetic interference (EMI) while maintaining adequate structural performance. This study investigates the influence of graphite powder on the mechanical, durability, and electromagnetic shielding performance of cement mortar incorporating a fixed 15% replacement of ball-milled waste iron mill scale. Graphite powder was incorporated at 0–5% by weight of cement. The effects of graphite content on flowability, mechanical properties, durability, electromagnetic shielding effectiveness, and microstructure were systematically evaluated. Compared with the control mix, the incorporation of 2% graphite powder increased the 28-day compressive, flexural, and tensile strengths by approximately 7.2%, 10.6%, and 13.0%, respectively, while simultaneously reducing water absorption, chloride permeability, and sulphate deterioration, indicating improved durability. Electromagnetic shielding effectiveness increased progressively with graphite content, reaching a maximum of 45.4 dB in the X-band frequency range. However, under the fixed 15% ball-milled waste iron mill scale replacement condition, the BW15-G2 mix provided the optimum balance between mechanical performance, durability, and electromagnetic shielding effectiveness, achieving 37.6 dB shielding performance. SEM observations revealed a denser matrix with refined pore structure, while XRD qualitatively indicated enhanced hydration product development in the optimized mix. Response surface methodology demonstrated that curing period predominantly influenced strength development, whereas graphite content governed matrix refinement and overall performance. The developed models and optimum graphite content are applicable only within the investigated fixed 15% ball-milled waste iron mill scale replacement level. The developed multifunctional cement mortar shows promising potential for EMI-sensitive infrastructure, including hospitals, data centres, telecommunication facilities, and defence structures.
SN - 2045-2322
ER -